These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

68 related articles for article (PubMed ID: 23789148)

  • 1. [Determination of threshold energy level of monopolar defibrillation pulses using the Luo-Rudy model of cardiomyocyte].
    Vostrikov BA; Gorbunov BB; Gusev AN; Selishchev SV
    Med Tekh; 2013; (2):6-9. PubMed ID: 23789148
    [No Abstract]   [Full Text] [Related]  

  • 2. An unconditionally stable numerical method for the Luo-Rudy 1 model used in simulations of defibrillation.
    Hanslien M; Sundnes J; Tveito A
    Math Biosci; 2007 Aug; 208(2):375-92. PubMed ID: 17306311
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal truncation of defibrillation pulses.
    Irnich W
    Pacing Clin Electrophysiol; 1995 Jun; 18(6):673-88. PubMed ID: 7659593
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cell and tissue responses to electric shocks.
    Ashihara T; Trayanova NA
    Europace; 2005 Sep; 7 Suppl 2():155-65. PubMed ID: 16102513
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal truncation of defibrillation pulses.
    Irnich W
    Pacing Clin Electrophysiol; 1995 Apr; 18(4 Pt 1):673-88. PubMed ID: 7596851
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Computer simulation methods of cardiac electrophysiology].
    Jin Y; Yang L; Zhang H; Huang Y; Jiang D
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Apr; 23(2):419-23. PubMed ID: 16706380
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using Physiome standards to couple cellular functions for rat cardiac excitation-contraction.
    Terkildsen JR; Niederer S; Crampin EJ; Hunter P; Smith NP
    Exp Physiol; 2008 Jul; 93(7):919-29. PubMed ID: 18344258
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sequential pulse defibrillation for implantable defibrillators.
    Bourland JD; Tacker WA; Wessale JL; Kallok MJ; Graf JE; Geddes LA
    Med Instrum; 1986; 20(3):138-42. PubMed ID: 3724587
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Basic study on a lower-energy defibrillation method using computer simulation and cultured myocardial cell models.
    Yaguchi A; Nagase K; Ishikawa M; Iwasaka T; Odagaki M; Hosaka H
    Conf Proc IEEE Eng Med Biol Soc; 2006; Suppl():6540-3. PubMed ID: 17959447
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Directional variability of stimulation threshold measurements in isolated guinea pig cardiomyocytes: relationship with orthogonal sequential defibrillating pulses.
    Bardou AL; Chesnais JM; Birkui PJ; Govaere MC; Auger PM; Von Euw D; Degonde J
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 1):1590-5. PubMed ID: 1704510
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Defibrillation and the upper limit of vulnerability to fibrillation in a transthoracic guinea pig model.
    Li H; Malkin RA
    J Electrocardiol; 1999 Apr; 32(2):159-66. PubMed ID: 10338034
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Theoretical predictions of the optimal monophasic and biphasic defibrillation waveshapes.
    Fishler MG
    IEEE Trans Biomed Eng; 2000 Jan; 47(1):59-67. PubMed ID: 10646280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative hypothermia increased defibrillation energy requirements.
    Kapetanopoulos A; Katsetos MC; Kluger J
    J Cardiovasc Med (Hagerstown); 2007 Sep; 8(9):741-3. PubMed ID: 17700410
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Defibrillation threshold computed from normal and supernormal excitable cardiac tissue.
    Zhang H; Holden AV
    Math Biosci; 2004; 188():175-90. PubMed ID: 14766101
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [A method of characteristic energy for comparative evaluation of monopolar defibrillation pulse efficiency].
    Gorbunov BB
    Med Tekh; 2009; (2):8-13. PubMed ID: 19437734
    [No Abstract]   [Full Text] [Related]  

  • 16. A method for analyzing the stability of the resting state for a model of pacemaker cells surrounded by stable cells.
    Artebrant R; Tveito A; Lines GT
    Math Biosci Eng; 2010 Jul; 7(3):505-26. PubMed ID: 20578783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Successes and failures in modeling heart cell electrophysiology.
    Noble D
    Heart Rhythm; 2011 Nov; 8(11):1798-803. PubMed ID: 21699872
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Defibrillation efficacy of a newly developed automated external defibrillator in a swine ventricular tachycardia/fibrillation model].
    Hui J; Gu YF; Wu XM; Zhu ZC; Song JP; Yang XJ; Liu ZH; Jiang TB; Fagn ZX; Jiang WP
    Zhonghua Xin Xue Guan Bing Za Zhi; 2009 Sep; 37(9):845-8. PubMed ID: 20128387
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Electrophysiological aspects on the problem of cardiac fibrillation and electric defibrillation].
    Antoni H
    Schweiz Med Wochenschr; 1969 Oct; 99(43):1530-9. PubMed ID: 4982989
    [No Abstract]   [Full Text] [Related]  

  • 20. Automated external defibrillators: design considerations.
    Kroll MW; Brewer JE
    New Horiz; 1997 May; 5(2):128-36. PubMed ID: 9153042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.