These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 23800729)

  • 1. Alternative FIB TEM sample preparation method for cross-sections of thin metal films deposited on polymer substrates.
    Rivera F; Davis R; Vanfleet R
    Microsc Microanal; 2013 Aug; 19(4):1080-91. PubMed ID: 23800729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combining Ar ion milling with FIB lift-out techniques to prepare high quality site-specific TEM samples.
    Huang Z
    J Microsc; 2004 Sep; 215(Pt 3):219-23. PubMed ID: 15312185
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A method for directly correlating site-specific cross-sectional and plan-view transmission electron microscopy of individual nanostructures.
    Schreiber DK; Adusumilli P; Hemesath ER; Seidman DN; Petford-Long AK; Lauhon LJ
    Microsc Microanal; 2012 Dec; 18(6):1410-8. PubMed ID: 23146147
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimization of focused ion beam damage in nanostructured polymer thin films.
    Kim S; Jeong Park M; Balsara NP; Liu G; Minor AM
    Ultramicroscopy; 2011 Feb; 111(3):191-9. PubMed ID: 21333856
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Method for Cross-sectional Thin Specimen Preparation from a Specific Site Using a Combination of a Focused Ion Beam System and Intermediate Voltage Electron Microscope and Its Application to the Characterization of a Precipitate in a Steel.
    Yaguchi T; Matsumoto H; Kamino T; Ishitani T; Urao R
    Microsc Microanal; 2001 May; 7(3):287-291. PubMed ID: 12597819
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigating the role of microbes in mineral weathering: nanometre-scale characterisation of the cell-mineral interface using FIB and TEM.
    Ward MB; Kapitulčinová D; Brown AP; Heard PJ; Cherns D; Cockell CS; Hallam KR; Ragnarsdóttir KV
    Micron; 2013 Apr; 47():10-7. PubMed ID: 23375115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy.
    Jarmar T; Palmquist A; Brånemark R; Hermansson L; Engqvist H; Thomsen P
    J Biomed Mater Res A; 2008 Dec; 87(4):1003-9. PubMed ID: 18257067
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cross-sectional sample preparation by focused ion beam: a review of ion-sample interaction.
    Ishitani T; Yaguchi T
    Microsc Res Tech; 1996 Nov; 35(4):320-33. PubMed ID: 8987026
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imaging thin films of nanoporous low-k dielectrics: comparison between ultramicrotomy and focused ion beam preparations for transmission electron microscopy.
    Thompson LE; Rice PM; Delenia E; Lee VY; Brock PJ; Magbitang TP; Dubois G; Volksen W; Miller RD; Kim HC
    Microsc Microanal; 2006 Apr; 12(2):156-9. PubMed ID: 17481352
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel method for the plan-view TEM preparation of thin samples on brittle substrates by mechanical and ion beam thinning.
    Sáfrán G; Grenet T
    Microsc Res Tech; 2002 Feb; 56(4):308-14. PubMed ID: 11877808
    [TBL] [Abstract][Full Text] [Related]  

  • 13. TEM sample preparation by FIB for carbon nanotube interconnects.
    Ke X; Bals S; Romo Negreira A; Hantschel T; Bender H; Van Tendeloo G
    Ultramicroscopy; 2009 Oct; 109(11):1353-9. PubMed ID: 19665846
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two-dimensional and 3-dimensional analysis of bone/dental implant interfaces with the use of focused ion beam and electron microscopy.
    Giannuzzi LA; Phifer D; Giannuzzi NJ; Capuano MJ
    J Oral Maxillofac Surg; 2007 Apr; 65(4):737-47. PubMed ID: 17368372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Warp-Free TEM Sample Preparation Methods Using FIB/SEM Systems.
    Cook SR
    Microsc Microanal; 2022 Sep; ():1-10. PubMed ID: 36081346
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Making the practically impossible "Merely difficult"--Cryogenic FIB lift-out for "Damage free" soft matter imaging.
    Parmenter CD; Fay MW; Hartfield C; Eltaher HM
    Microsc Res Tech; 2016 Apr; 79(4):298-303. PubMed ID: 26875988
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dopant mapping in thin FIB prepared silicon samples by Off-Axis Electron Holography.
    Pantzer A; Vakahy A; Eliyahou Z; Levi G; Horvitz D; Kohn A
    Ultramicroscopy; 2014 Mar; 138():36-45. PubMed ID: 24486529
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).
    Drobne D
    Methods Mol Biol; 2013; 950():275-92. PubMed ID: 23086881
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2D-mapping of dopant distribution in deep sub micron CMOS devices by electron holography using adapted FIB-preparation.
    Lenk A; Lichte H; Muehle U
    J Electron Microsc (Tokyo); 2005 Aug; 54(4):351-9. PubMed ID: 16123059
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In situ lift-out dedicated techniques using FIB-SEM system for TEM specimen preparation.
    Tomus D; Ng HP
    Micron; 2013 Jan; 44():115-9. PubMed ID: 22664233
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.