These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 23812153)

  • 21. Infection after spanning external fixation for high-energy tibial plateau fractures: is pin site-plate overlap a problem?
    Laible C; Earl-Royal E; Davidovitch R; Walsh M; Egol KA
    J Orthop Trauma; 2012 Feb; 26(2):92-7. PubMed ID: 22011631
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Medial Displacement Calcaneal Osteotomy: A Comparison of Screw Versus Locking Plate Fixation.
    Saxena A; Patel R
    J Foot Ankle Surg; 2016; 55(6):1164-1168. PubMed ID: 27640930
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates].
    Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Distal tibial/fibular derotation osteotomy for correction of tibial torsion: review of technique and results in 63 cases.
    Dodgin DA; De Swart RJ; Stefko RM; Wenger DR; Ko JY
    J Pediatr Orthop; 1998; 18(1):95-101. PubMed ID: 9449109
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Is lag screw fixation superior to plate fixation to treat fractures of the mandibular symphysis?
    Ellis E
    J Oral Maxillofac Surg; 2012 Apr; 70(4):875-82. PubMed ID: 22209100
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Tibial fixation in anterior cruciate ligament reconstruction with bone-patellar tendon-bone and semitendinosus-gracilis autografts: a comparison between bioabsorbable screws and bioabsorbable cross-pin fixation.
    Volpi P; Marinoni L; Bait C; Galli M; de Girolamo L
    Am J Sports Med; 2009 Apr; 37(4):808-12. PubMed ID: 19218557
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical study of a unilocking T-plate system for prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.
    Avery CM; Skidmore M; Peden A; Pan J
    Oral Oncol; 2011 Apr; 47(4):268-73. PubMed ID: 21388860
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fixation techniques in lower extremity correction osteotomies and fractures in mild-to-severe osteogenesis imperfecta patients: evaluation of the results and complications.
    Emet A; Yilmaz ET; Danisman M; Aksoy C; Yilmaz G
    J Orthop Surg Res; 2023 Jun; 18(1):437. PubMed ID: 37328762
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Supramalleolar osteotomy for unilateral tibial torsion.
    Savva N; Ramesh R; Richards RH
    J Pediatr Orthop B; 2006 May; 15(3):190-3. PubMed ID: 16601587
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Feasibility of absorbable plates and screws for fixation in reduction malarplasty with L-shaped osteotomy.
    Tan W; Niu F; Yu B; Gui L
    J Craniofac Surg; 2011 Mar; 22(2):546-50. PubMed ID: 21403525
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Multilevel osteotomy with Rush pin fixation in treatment of osteogenesis imperfecta].
    Napiontek M; Shadi M; Czubak J
    Chir Narzadow Ruchu Ortop Pol; 1994; 59(5):441-6. PubMed ID: 7736810
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Isolated congenital pseudoarthrosis of the fibula: a comparison of fibular osteosynthesis with distal tibiofibular synostosis.
    Martus JE; Johnston CE
    J Pediatr Orthop; 2008 Dec; 28(8):825-30. PubMed ID: 19034172
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of two osteotomy techniques for tibial lengthening.
    Eralp L; Kocaoğlu M; Ozkan K; Türker M
    Arch Orthop Trauma Surg; 2004 Jun; 124(5):298-300. PubMed ID: 15034725
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Recurrence of varus deformity after proximal tibial osteotomy in Blount disease: long-term follow-up.
    Chotigavanichaya C; Salinas G; Green T; Moseley CF; Otsuka NY
    J Pediatr Orthop; 2002; 22(5):638-41. PubMed ID: 12198467
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate.
    Stoffel K; Stachowiak G; Kuster M
    Clin Biomech (Bristol, Avon); 2004 Nov; 19(9):944-50. PubMed ID: 15475127
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Fractures of the femoral neck: a review and personal statement.
    Raaymakers EL
    Acta Chir Orthop Traumatol Cech; 2006; 73(1):45-59. PubMed ID: 16613748
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Complications of tibial osteotomies in children with comorbidities.
    Payman KR; Patenall V; Borden P; Green T; Otsuka NY
    J Pediatr Orthop; 2002; 22(5):642-4. PubMed ID: 12198468
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparing fixation used for calcaneal displacement osteotomies: a look at removal rates and cost.
    Lucas DE; Simpson GA; Philbin TM
    Foot Ankle Spec; 2015 Feb; 8(1):18-22. PubMed ID: 25380837
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Rotation or derotation osteotomy of the tibia].
    Kolp D; Ziebarth K; Slongo T
    Oper Orthop Traumatol; 2017 Apr; 29(2):163-172. PubMed ID: 27957593
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.