BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

383 related articles for article (PubMed ID: 23822435)

  • 1. Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy.
    Stathakis S; Myers P; Esquivel C; Mavroidis P; Papanikolaou N
    Med Phys; 2013 Jul; 40(7):071731. PubMed ID: 23822435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA.
    Olch AJ
    Med Phys; 2012 Jan; 39(1):81-6. PubMed ID: 22225277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements.
    Knill C; Snyder M; Rakowski JT; Zhuang L; Matuszak M; Burmeister J
    Med Phys; 2016 May; 43(5):2476. PubMed ID: 27147358
    [TBL] [Abstract][Full Text] [Related]  

  • 4. VMAT QA: measurement-guided 4D dose reconstruction on a patient.
    Nelms BE; Opp D; Robinson J; Wolf TK; Zhang G; Moros E; Feygelman V
    Med Phys; 2012 Jul; 39(7):4228-38. PubMed ID: 22830756
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.
    Jeevanandam P; Agnew CE; Irvine DM; McGarry CK
    Med Phys; 2018 Apr; 45(4):1738-1747. PubMed ID: 29431850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
    Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
    Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3D dose reconstruction of pretreatment verification plans using multiple 2D planes from the OCTAVIUS/Seven29 phantom array.
    Calvo O; Stathakis S; Gutiérrez AN; Esquivel C; Papanikolaou N
    Technol Cancer Res Treat; 2012 Feb; 11(1):69-82. PubMed ID: 22181333
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A method to reconstruct and apply 3D primary fluence for treatment delivery verification.
    Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D
    J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA.
    Alhazmi A; Gianoli C; Neppl S; Martins J; Veloza S; Podesta M; Verhaegen F; Reiner M; Belka C; Parodi K
    Phys Med Biol; 2018 May; 63(11):115002. PubMed ID: 29714714
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom.
    Yang B; Geng H; Ding Y; Kong CW; Cheung CW; Chiu TL; Lam WW; Cheung KY; Yu SK
    Med Dosim; 2019 Spring; 44(1):83-90. PubMed ID: 29602598
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT.
    Rajasekaran D; Jeevanandam P; Sukumar P; Ranganathan A; Johnjothi S; Nagarajan V
    Med Dosim; 2014; 39(4):300-8. PubMed ID: 24910246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT.
    Nelms BE; Opp D; Zhang G; Moros E; Feygelman V
    Med Phys; 2014 Jun; 41(6):061704. PubMed ID: 24877799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patient-specific quality assurance for the delivery of (60)Co intensity modulated radiation therapy subject to a 0.35-T lateral magnetic field.
    Li HH; Rodriguez VL; Green OL; Hu Y; Kashani R; Wooten HO; Yang D; Mutic S
    Int J Radiat Oncol Biol Phys; 2015 Jan; 91(1):65-72. PubMed ID: 25442343
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
    O'Daniel J; Das S; Wu QJ; Yin FF
    Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation and IMRT/VMAT delivery quality of a preconfigured fast-rotating O-ring linac system.
    De Roover R; Crijns W; Poels K; Michiels S; Nulens A; Vanstraelen B; Petillion S; De Brabandere M; Haustermans K; Depuydt T
    Med Phys; 2019 Jan; 46(1):328-339. PubMed ID: 30417523
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SU-E-T-100: How to Improve the Dose Accuracy for Gantry Angle Dependent Patient Specific IMRT QA Using 2D Ion Chamber Array with Octavius Phantom.
    Choi D; Nookala P; Patyal B
    Med Phys; 2012 Jun; 39(6Part11):3725. PubMed ID: 28517133
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT.
    Korevaar EW; Wauben DJ; van der Hulst PC; Langendijk JA; Van't Veld AA
    Radiother Oncol; 2011 Sep; 100(3):446-52. PubMed ID: 21963288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.
    Létourneau D; Publicover J; Kozelka J; Moseley DJ; Jaffray DA
    Med Phys; 2009 May; 36(5):1813-21. PubMed ID: 19544800
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom.
    Van Esch A; Clermont C; Devillers M; Iori M; Huyskens DP
    Med Phys; 2007 Oct; 34(10):3825-37. PubMed ID: 17985628
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.