  • 1. Measuring accuracy of sphygmomanometers in the medical practices of Swiss primary care physicians.
    Zuber M; Schäfer HH; Kaiser W; Erne P
    Eur J Gen Pract; 2013 Dec; 19(4):244-7. PubMed ID: 23822652
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care.
    Coleman AJ; Steel SD; Ashworth M; Vowler SL; Shennan A
    Blood Press Monit; 2005 Aug; 10(4):181-8. PubMed ID: 16077263
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The extent and implications of sphygmomanometer calibration error in primary care.
    Rouse A; Marshall T
    J Hum Hypertens; 2001 Sep; 15(9):587-91. PubMed ID: 11550103
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hidden errors of aneroid sphygmomanometers.
    Waugh JJ; Gupta M; Rushbrook J; Halligan A; Shennan AH
    Blood Press Monit; 2002 Dec; 7(6):309-12. PubMed ID: 12488650
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical assessment of blood pressure.
    McKay DW; Campbell NR; Parab LS; Chockalingam A; Fodor JG
    J Hum Hypertens; 1990 Dec; 4(6):639-45. PubMed ID: 2096205
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study.
    A'Court C; Stevens R; Sanders S; Ward A; McManus R; Heneghan C
    Br J Gen Pract; 2011 Sep; 61(590):e598-603. PubMed ID: 22152749
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sphygmomanometer calibration--why, how and how often?
    Turner MJ; Speechly C; Bignell N
    Aust Fam Physician; 2007 Oct; 36(10):834-8. PubMed ID: 17925905
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Devices and techniques for blood pressure measurement and criteria for hypertension adopted by Brazilian physicians: exploratory study.
    Mion D; Pierin AM; Lessa I; Nobre F
    Arq Bras Cardiol; 2002 Dec; 79(6):597-600, 593-6. PubMed ID: 12532243
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-measurement of blood pressure at home: is it reliable?
    Dilek M; Adibelli Z; Aydogdu T; Koksal AR; Cakar B; Akpolat T
    Blood Press; 2008; 17(1):34-41. PubMed ID: 18568690
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of monitors used for blood pressure checks in English retail pharmacies: a cross-sectional observational study.
    Hodgkinson J; Koshiaris C; Martin U; Mant J; Heneghan C; Hobbs FR; McManus RJ
    Br J Gen Pract; 2016 May; 66(646):e309-14. PubMed ID: 27025555
    [TBL] [Abstract][Full Text] [Related]  

  • 11. How accurate are sphygmomanometers?
    Mion D; Pierin AM
    J Hum Hypertens; 1998 Apr; 12(4):245-8. PubMed ID: 9607693
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oscillometric wrist blood pressure measuring devices.
    Braam RL; Asian B; Thien T
    Neth J Med; 2003 Oct; 61(10):313-7. PubMed ID: 14708908
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lack of sphygmomanometer calibration causes over- and under-detection of hypertension: a computer simulation study.
    Turner MJ; Irwig L; Bune AJ; Kam PC; Baker AB
    J Hypertens; 2006 Oct; 24(10):1931-8. PubMed ID: 16957551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of terminal digit preference by family physicians and sphygmomanometer calibration errors on blood pressure value: implication for hypertension screening.
    Niyonsenga T; Vanasse A; Courteau J; Cloutier L
    J Clin Hypertens (Greenwich); 2008 May; 10(5):341-7. PubMed ID: 18453792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Home blood pressure measurement with oscillometric upper-arm devices.
    Braam RL; Thien T
    Neth J Med; 2003 Oct; 61(10):307-12. PubMed ID: 14708907
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The results of the campaign for evaluating sphygmomanometers accuracy and their physical conditions.
    Mion Júnior D; Pierin AM; Alavarce DC; Vasconcellos JH
    Arq Bras Cardiol; 2000 Jan; 74(1):31-8. PubMed ID: 10935290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of sphygmomanometers at pharmacies.
    Erdem DG; Erdem E; Dilek M; Aydogdu T; Selim N; Demiray F; Sari A; Akpolat T
    Kidney Blood Press Res; 2009; 32(4):231-4. PubMed ID: 19622898
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of sphygmomanometers used by family physicians practicing outside the hospital environment in Bas-Saint-Laurent].
    Vanasse A; Courteau J
    Can Fam Physician; 2001 Feb; 47():281-6. PubMed ID: 11228028
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Value of blood pressure of adults depending on method of measurement].
    Wielemborek-Musiał K; Jegier A
    Pol Arch Med Wewn; 2006 Jun; 115(6):529-34. PubMed ID: 17263224
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sphygmomanometers in use in general practice: an overlooked aspect of quality in patient care.
    Knight T; Leech F; Jones A; Walker L; Wickramasinghe R; Angris S; Rolfe P
    J Hum Hypertens; 2001 Oct; 15(10):681-4. PubMed ID: 11607797
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]