These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 23823052)
1. Effect of elbow flexion on the proximity of the PIN during 2-incision distal biceps repair. Jones JA; Jones CM; Grossman MG Orthopedics; 2013 Jul; 36(7):e931-5. PubMed ID: 23823052 [TBL] [Abstract][Full Text] [Related]
2. How to Avoid Posterior Interosseous Nerve Injury During Single-Incision Distal Biceps Repair Drilling. Becker D; Lopez-Marambio FA; Hammer N; Kieser D Clin Orthop Relat Res; 2019 Feb; 477(2):424-431. PubMed ID: 30444757 [TBL] [Abstract][Full Text] [Related]
3. Use of cortical buttons for the fixation of the distal biceps tendon in combination with the double-incision technique-the relationship between the drill trajectory and the proximity to the posterior interosseous nerve: a cadaveric study. Benninger E; Meier C J Shoulder Elbow Surg; 2018 Nov; 27(11):2077-2084. PubMed ID: 30121153 [TBL] [Abstract][Full Text] [Related]
4. Avoiding the posterior interosseous nerve during 2-incision distal biceps tendon repair: an anatomic study. Chan J; Habis AA; Alzaben E; Bicknell RT; Daneshvar P J Shoulder Elbow Surg; 2023 Oct; 32(10):2152-2160. PubMed ID: 37331500 [TBL] [Abstract][Full Text] [Related]
5. Distance of the Posterior Interosseous Nerve From the Bicipital (Radial) Tuberosity at Varying Positions of Forearm Rotation: A Magnetic Resonance Imaging Study With Clinical Implications. Luthringer TA; Bloom DA; Klein DS; Baron SL; Alaia EF; Burke CJ; Meislin RJ Am J Sports Med; 2021 Apr; 49(5):1152-1159. PubMed ID: 33635730 [TBL] [Abstract][Full Text] [Related]
6. Clinical outcomes and safety of distal biceps repair using a modified entry point. Baba M; Leon JV; Symes M; Dorrestijn O; Young A; Cass B ANZ J Surg; 2017 May; 87(5):376-379. PubMed ID: 27490020 [TBL] [Abstract][Full Text] [Related]
7. Biomechanical analysis of distal biceps tendon repair methods. Henry J; Feinblatt J; Kaeding CC; Latshaw J; Litsky A; Sibel R; Stephens JA; Jones GL Am J Sports Med; 2007 Nov; 35(11):1950-4. PubMed ID: 17664341 [TBL] [Abstract][Full Text] [Related]
8. The Importance of Preserving the Radial Tuberosity During Distal Biceps Repair. Schmidt CC; Brown BT; Williams BG; Rubright JH; Schmidt DL; Pic AC; Nakashian MR; Schimoler PJ; Miller MC J Bone Joint Surg Am; 2015 Dec; 97(24):2014-23. PubMed ID: 26677235 [TBL] [Abstract][Full Text] [Related]
9. The effect of drilling angle on posterior interosseous nerve safety during open and endoscopic anterior single-incision repair of the distal biceps tendon. Saldua N; Carney J; Dewing C; Thompson M Arthroscopy; 2008 Mar; 24(3):305-10. PubMed ID: 18308182 [TBL] [Abstract][Full Text] [Related]
10. Proximity of the posterior interosseous nerve during cortical button guidewire placement for distal biceps tendon reattachment. Thumm N; Hutchinson D; Zhang C; Drago S; Tyser AR J Hand Surg Am; 2015 Mar; 40(3):534-6. PubMed ID: 25510155 [TBL] [Abstract][Full Text] [Related]
11. Double-Incision Technique for the Treatment of Distal Biceps Tendon Rupture. Mercurio M; Castioni D; Cosentino O; Fanelli D; Familiari F; Gasparini G; Galasso O JBJS Essent Surg Tech; 2022; 12(3):e21.00033. PubMed ID: 36816526 [TBL] [Abstract][Full Text] [Related]
12. Posterior Interosseous Nerve Proximity to Cortical Button Implant for Distal Biceps Repair With Single and 2-Incision Approaches. Strong BM; Voloshin I J Hand Surg Am; 2019 Jul; 44(7):613.e1-613.e6. PubMed ID: 30301643 [TBL] [Abstract][Full Text] [Related]
13. Innervation of the supinator muscle and its relationship to two-incision distal biceps tendon repair: an anatomic study. Duquin TR; Chavan PR; Bisson LJ Clin Anat; 2010 May; 23(4):413-9. PubMed ID: 20432378 [TBL] [Abstract][Full Text] [Related]
14. Safe Drill Trajectory for Anatomic Repair of Distal Biceps Tendon Through a Single Incision: A Cadaveric Study. Mwaturura T; Peters MJ; Glaris Z; Goetz TJ J Hand Surg Am; 2023 Nov; 48(11):1160.e1-1160.e5. PubMed ID: 35672176 [TBL] [Abstract][Full Text] [Related]
15. Elbow Positioning and Joint Insufflation Substantially Influence Median and Radial Nerve Locations. Hackl M; Lappen S; Burkhart KJ; Leschinger T; Scaal M; Müller LP; Wegmann K Clin Orthop Relat Res; 2015 Nov; 473(11):3627-34. PubMed ID: 26152782 [TBL] [Abstract][Full Text] [Related]
16. Risk of Posterior Interosseous Nerve Injury During Distal Biceps Tendon Repair Using a Cortical Button. Lynch B; Duke A; Komatsu D; Wang E J Hand Surg Glob Online; 2022 Jan; 4(1):14-18. PubMed ID: 35415600 [TBL] [Abstract][Full Text] [Related]
17. [Evaluation of surgical repair of distal biceps tendon ruptures]. Behounek J; Hrubina M; Skoták M; Krumpl O; Zahálka M; Dvorák J; Fucík M Acta Chir Orthop Traumatol Cech; 2009 Feb; 76(1):47-53. PubMed ID: 19268049 [TBL] [Abstract][Full Text] [Related]
18. Pressure Distribution to the Distal Biceps Tendon at the Radial Tuberosity: A Biomechanical Study. Rausch V; Kahmann SL; Baltschun C; Staat M; Müller LP; Wegmann K J Hand Surg Am; 2020 Aug; 45(8):776.e1-776.e9. PubMed ID: 32151407 [TBL] [Abstract][Full Text] [Related]
19. Use of a Bicortical Button to Safely Repair the Distal Biceps in a Two-Incision Approach: A Cadaveric Analysis. Barlow JD; McNeilan RJ; Speeckaert A; Beals CT; Awan HM J Hand Surg Am; 2017 Jul; 42(7):570.e1-570.e6. PubMed ID: 28434835 [TBL] [Abstract][Full Text] [Related]
20. Repair of distal biceps tendon rupture: a new technique using the Endobutton. Bain GI; Prem H; Heptinstall RJ; Verhellen R; Paix D J Shoulder Elbow Surg; 2000; 9(2):120-6. PubMed ID: 10810691 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]