These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 23827068)

  • 1. [Parameter optimization for non-contrast-enhanced selective magnetic resonance portography imaging].
    Wang X; Du SD; Xue HD; Jin ZY; Yang YY; Liu MY; Zhao XZ; Sun ZY; Jin Y; Sun HY
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2013 Jun; 35(3):299-304. PubMed ID: 23827068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging with three-dimensional half-fourier fast spin-echo and true steady-state free-precession sequences.
    Shimada K; Isoda H; Okada T; Kamae T; Arizono S; Hirokawa Y; Shibata T; Togashi K
    J Magn Reson Imaging; 2009 May; 29(5):1140-6. PubMed ID: 19388119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-contrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results.
    Shimada K; Isoda H; Okada T; Maetani Y; Arizono S; Hirokawa Y; Kamae T; Togashi K
    Eur J Radiol; 2009 Apr; 70(1):111-7. PubMed ID: 18249518
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Non-contrast-enhanced MR portography with balanced steady-state free-precession sequence and time-spatial labeling inversion pulses: comparison of imaging with flow-in and flow-out methods.
    Furuta A; Isoda H; Yamashita R; Ohno T; Kawahara S; Shimizu H; Fujimoto K; Kido A; Kusahara H; Togashi K
    J Magn Reson Imaging; 2014 Sep; 40(3):583-7. PubMed ID: 24924213
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-contrast-enhanced 3D MR portography within a breath-hold using compressed sensing acceleration: A prospective noninferiority study.
    Ono A; Arizono S; Fujimoto K; Akasaka T; Yamashita R; Furuta A; Isoda H; Togashi K
    Magn Reson Imaging; 2017 Nov; 43():42-47. PubMed ID: 28688951
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-contrast-enhanced MR angiography for selective visualization of the hepatic vein and inferior vena cava with true steady-state free-precession sequence and time-spatial labeling inversion pulses: preliminary results.
    Shimada K; Isoda H; Okada T; Kamae T; Maetani Y; Arizono S; Hirokawa Y; Shibata T; Togashi K
    J Magn Reson Imaging; 2009 Feb; 29(2):474-9. PubMed ID: 19161205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Visualization of external carotid artery and its branches: non-contrast-enhanced MR angiography using balanced steady-state free-precession sequence and a time-spatial labeling inversion pulse.
    Satogami N; Okada T; Koyama T; Gotoh K; Kamae T; Togashi K
    J Magn Reson Imaging; 2009 Sep; 30(3):678-83. PubMed ID: 19711418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unenhanced MR portography with a half-Fourier fast spin-echo sequence and time-space labeling inversion pulses: preliminary results.
    Shimada K; Isoda H; Okada T; Kamae T; Arizono S; Hirokawa Y; Togashi K
    AJR Am J Roentgenol; 2009 Jul; 193(1):106-12. PubMed ID: 19542401
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison of imaging with the short tau inversion recovery method and the chemical shift selective method.
    Shimizu H; Isoda H; Ohno T; Yamashita R; Kawahara S; Furuta A; Fujimoto K; Kido A; Kusahara H; Togashi K
    Magn Reson Imaging; 2015 Jan; 33(1):81-5. PubMed ID: 25159471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP).
    Kanki A; Ito K; Tamada T; Noda Y; Yamamoto A; Tanimoto D; Sato T; Higaki A
    J Magn Reson Imaging; 2013 May; 37(5):1178-81. PubMed ID: 23152307
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity.
    Kurata Y; Kido A; Fujimoto K; Kiguchi K; Takakura K; Moribata Y; Shitano F; Himoto Y; Fushimi Y; Okada T; Togashi K
    Abdom Radiol (NY); 2016 Jan; 41(1):119-26. PubMed ID: 26830618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla.
    Kawahara S; Isoda H; Ohno T; Furuta A; Togashi K
    Acta Radiol Open; 2015 Dec; 4(12):2058460115616427. PubMed ID: 26668756
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location.
    Zhang Y; Xing Z; Liu Y; She D; Zeng Z; Cao D
    Abdom Imaging; 2014 Oct; 39(5):1000-8. PubMed ID: 24687245
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noncontrast 3D steady-state free-precession magnetic resonance angiography of the whole chest using nonselective radiofrequency excitation over a large field of view: comparison with single-phase 3D contrast-enhanced magnetic resonance angiography.
    Krishnam MS; Tomasian A; Deshpande V; Tran L; Laub G; Finn JP; Ruehm SG
    Invest Radiol; 2008 Jun; 43(6):411-20. PubMed ID: 18496046
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla.
    Ohno T; Isoda H; Furuta A; Togashi K
    Acta Radiol Open; 2015 May; 4(5):2058460115584110. PubMed ID: 26019890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contrast changes in portal vein and bile duct between centric and linear k-space ordering on three-dimensional segmented true fast imaging with steady-state precession magnetic resonance imaging.
    Morita S; Saito N; Suzuki K; Ohnishi T; Imura C; Mitsuhashi N
    Magn Reson Imaging; 2008 Nov; 26(9):1244-9. PubMed ID: 18499383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Noncontrast 3D steady state free precession magnetic resonance angiography of the thoracic central veins using nonselective radiofrequency excitation over a large field of view: initial experience.
    Tomasian A; Lohan DG; Laub G; Singhal A; Finn JP; Krishnam MS
    Invest Radiol; 2008 May; 43(5):306-13. PubMed ID: 18424951
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement.
    Surányi P; Kiss P; Ruzsics B; Brott BC; Simor T; Elgavish GA
    Magn Reson Imaging; 2007 Jun; 25(5):641-51. PubMed ID: 17540275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [MR coronary angiography with MS-325, a blood pool contrast agent: comparison of an inversion recovery steady-state free precession with an inversion recovery fast low angle shot sequence in volunteers].
    Nassenstein K; Waltering KU; Eggebrecht H; Schlosser T; Hunold P; Barkhausen J
    Rofo; 2006 May; 178(5):508-14. PubMed ID: 16586314
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraportal venous flow distribution: evaluation with single breath-hold ECG-triggered three-dimensional half-Fourier fast spin-echo MR imaging and a selective inversion-recovery tagging pulse.
    Ito K; Koike S; Jo C; Shimizu A; Kanazawa H; Miyazaki M; Yamauchi S; Matsunaga N
    AJR Am J Roentgenol; 2002 Feb; 178(2):343-8. PubMed ID: 11804889
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.