These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
212 related articles for article (PubMed ID: 23829608)
1. One-sample determination of glomerular filtration rate (GFR) in children. An evaluation based on 75 consecutive patients. Henriksen UL; Kanstrup IL; Henriksen JH Scand J Clin Lab Invest; 2013 Sep; 73(6):466-75. PubMed ID: 23829608 [TBL] [Abstract][Full Text] [Related]
2. Chromium-51-EDTA clearance in adults with a single-plasma sample. Mårtensson J; Groth S; Rehling M; Gref M J Nucl Med; 1998 Dec; 39(12):2131-7. PubMed ID: 9867156 [TBL] [Abstract][Full Text] [Related]
3. Total plasma clearance versus urinary plasma clearance of (51)Cr-EDTA in patients with cirrhosis with and without fluid retention. Henriksen UL; Hansen HB; Ring-Larsen H; Bendtsen F; Henriksen JH Scand J Clin Lab Invest; 2015 Jan; 75(1):64-72. PubMed ID: 25410087 [TBL] [Abstract][Full Text] [Related]
4. Mannitol clearance for the determination of glomerular filtration rate-a validation against clearance of Kiss K; Molnár M; Söndergaard S; Molnár G; Ricksten SE Clin Physiol Funct Imaging; 2018 Jan; 38(1):10-16. PubMed ID: 27256921 [TBL] [Abstract][Full Text] [Related]
5. Estimating GFR in children with 99mTc-DTPA renography: a comparison with single-sample 51Cr-EDTA clearance. Gutte H; Møller ML; Pfeifer AK; Thorup J; Borgwardt L; Borgwardt L; Kristoffersen US; Kjaer A Clin Physiol Funct Imaging; 2010 May; 30(3):169-74. PubMed ID: 20214666 [TBL] [Abstract][Full Text] [Related]
6. 68Ga-EDTA PET/CT imaging and plasma clearance for glomerular filtration rate quantification: comparison to conventional 51Cr-EDTA. Hofman M; Binns D; Johnston V; Siva S; Thompson M; Eu P; Collins M; Hicks RJ J Nucl Med; 2015 Mar; 56(3):405-9. PubMed ID: 25678493 [TBL] [Abstract][Full Text] [Related]
7. Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA. Hansen HP; Rossing P; Mathiesen ER; Hommel E; Smidt UM; Parving HH Scand J Clin Lab Invest; 1998 Aug; 58(5):405-13. PubMed ID: 9819189 [TBL] [Abstract][Full Text] [Related]
8. Correlation of various published radionuclide glomerular filtration rate estimation techniques and proposed paediatric normative data. Bhatt MK; Bartlett ML; Mallitt KA; McTaggart S; Ravi Kumar AS Nucl Med Commun; 2011 Nov; 32(11):1088-94. PubMed ID: 21897307 [TBL] [Abstract][Full Text] [Related]
10. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance. Jødal L; Brøchner-Mortensen J Scand J Clin Lab Invest; 2009; 69(3):305-13. PubMed ID: 19048437 [TBL] [Abstract][Full Text] [Related]
12. Conventional measurements of GFR using 51Cr-EDTA overestimate true renal clearance by 10 percent. Moore AE; Park-Holohan SJ; Blake GM; Fogelman I Eur J Nucl Med Mol Imaging; 2003 Jan; 30(1):4-8. PubMed ID: 12483403 [TBL] [Abstract][Full Text] [Related]
13. Simultaneous urography and determination of glomerular filtration rate. A comparison of total plasma clearances of iohexol and 51Cr-EDTA in plegic patients. Lundqvist S; Hietala SO; Berglund C; Karp K Acta Radiol; 1994 Jul; 35(4):391-5. PubMed ID: 8011391 [TBL] [Abstract][Full Text] [Related]
14. Determination of optimal sampling times for a two blood sample clearance method using (51)Cr-EDTA in cats. Vandermeulen E; De Sadeleer C; Piepsz A; Ham HR; Dobbeleir AA; Vermeire ST; Van Hoek IM; Daminet S; Slegers G; Peremans KY J Feline Med Surg; 2010 Aug; 12(8):577-83. PubMed ID: 20452793 [TBL] [Abstract][Full Text] [Related]
15. Suitability of a simplified technique based on iohexol for decentralized measurement of glomerular filtration rate. Bird NJ; Peters C; Michell AR; Peters AM Scand J Urol Nephrol; 2008; 42(5):472-80. PubMed ID: 18609287 [TBL] [Abstract][Full Text] [Related]
16. Checking the consistency of the two blood samples slope-intercept method for estimating GFR using the single blood sample formula in children. De Sadeleer C; Piepsz A; Ham HR Nucl Med Commun; 2007 Jan; 28(1):49-54. PubMed ID: 17159549 [TBL] [Abstract][Full Text] [Related]
17. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods. Rehling M; Rabøl A Clin Physiol; 1989 Apr; 9(2):171-82. PubMed ID: 2498028 [TBL] [Abstract][Full Text] [Related]
18. Development of a modified sampling and calculation method for isotope plasma clearance assessment of the glomerular filtration rate in patients with cirrhosis and ascites. Wickham F; Burniston MT; Xirouchakis E; Theocharidou E; Wesolowski CA; Hilson AJ; Burroughs AK Nucl Med Commun; 2013 Nov; 34(11):1124-32. PubMed ID: 23995396 [TBL] [Abstract][Full Text] [Related]
19. Estimation of glomerular filtration rate in infants and in children using a single-plasma sample method. Ham HR; Piepsz A J Nucl Med; 1991 Jun; 32(6):1294-7. PubMed ID: 1904483 [TBL] [Abstract][Full Text] [Related]
20. Normalization of glomerular filtration rate in children: body surface area, body weight or extracellular fluid volume? Peters AM; Gordon I; Sixt R J Nucl Med; 1994 Mar; 35(3):438-44. PubMed ID: 8113892 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]