185 related articles for article (PubMed ID: 23831149)
1. Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.
Baykal D; Siskey RS; Haider H; Saikko V; Ahlroos T; Kurtz SM
J Mech Behav Biomed Mater; 2014 Mar; 31():117-34. PubMed ID: 23831149
[TBL] [Abstract][Full Text] [Related]
2. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
[TBL] [Abstract][Full Text] [Related]
3. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE).
Muratoglu OK; Bragdon CR; O'Connor DO; Jasty M; Harris WH; Gul R; McGarry F
Biomaterials; 1999 Aug; 20(16):1463-70. PubMed ID: 10458559
[TBL] [Abstract][Full Text] [Related]
4. Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements.
Kurtz SM; Villarraga ML; Herr MP; Bergström JS; Rimnac CM; Edidin AA
Biomaterials; 2002 Sep; 23(17):3681-97. PubMed ID: 12109694
[TBL] [Abstract][Full Text] [Related]
5. Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.
Shen J; Gao G; Liu X; Fu J
Clin Orthop Relat Res; 2015 Mar; 473(3):760-6. PubMed ID: 25106800
[TBL] [Abstract][Full Text] [Related]
6. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
[TBL] [Abstract][Full Text] [Related]
7. Effect of type of contact, counterface surface roughness, and contact area on the wear and friction of extensively cross-linked, vitamin E stabilized UHMWPE.
Saikko V
J Biomed Mater Res B Appl Biomater; 2020 Jul; 108(5):1985-1992. PubMed ID: 31833185
[TBL] [Abstract][Full Text] [Related]
8. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.
Zaki M; Aljinaidi A; Hamed M
Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170
[TBL] [Abstract][Full Text] [Related]
9. Screening of stabilized crosslinked polyethylene using a novel wear tester.
Hoffmann M; Gonzalez-Mora V; Chiesa R; Cigada A; Stroosnijder MF
Biomed Mater Eng; 2002; 12(4):387-95. PubMed ID: 12652033
[TBL] [Abstract][Full Text] [Related]
10. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
[TBL] [Abstract][Full Text] [Related]
11. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
Kang L; Galvin AL; Jin ZM; Fisher J
Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
[TBL] [Abstract][Full Text] [Related]
12. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations.
Galvin AL; Tipper JL; Jennings LM; Stone MH; Jin ZM; Ingham E; Fisher I
Proc Inst Mech Eng H; 2007 Jan; 221(1):1-10. PubMed ID: 17315763
[TBL] [Abstract][Full Text] [Related]
13. Influence of heat treatment on structural, mechanical and wear properties of crosslinked UHMWPE.
Chiesa R; Moscatelli M; Giordano C; Siccardi F; Cigada A
J Appl Biomater Biomech; 2004; 2(1):20-8. PubMed ID: 20803447
[TBL] [Abstract][Full Text] [Related]
14. Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: an in vitro experimental model.
Greenbaum ES; Burroughs BB; Harris WH; Muratoglu OK
Biomaterials; 2004 Aug; 25(18):4479-84. PubMed ID: 15046938
[TBL] [Abstract][Full Text] [Related]
15. [Improve wear resistance of UHMWPE by O+ ion implanted].
Xiong D
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):583-5, 596. PubMed ID: 14716850
[TBL] [Abstract][Full Text] [Related]
16. Comparative wear tests of ultra-high molecular weight polyethylene and cross-linked polyethylene.
Harsha AP; Joyce TJ
Proc Inst Mech Eng H; 2013 May; 227(5):600-8. PubMed ID: 23637270
[TBL] [Abstract][Full Text] [Related]
17. Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene.
Abdelgaied A; Brockett CL; Liu F; Jennings LM; Fisher J; Jin Z
Proc Inst Mech Eng H; 2013 Jan; 227(1):18-26. PubMed ID: 23516952
[TBL] [Abstract][Full Text] [Related]
18. Experimental and numerical modeling of variable friction between nanoregions in coventional and crosslinked UHMWPE.
Ho SP; Joseph PF; Drews MJ; Boland T; LaBerge M
J Biomech Eng; 2004 Feb; 126(1):111-9. PubMed ID: 15171137
[TBL] [Abstract][Full Text] [Related]
19. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.
Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J
Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418
[TBL] [Abstract][Full Text] [Related]
20. Wear of crosslinked polyethylene under different tribological conditions.
Galvin A; Kang L; Tipper J; Stone M; Ingham E; Jin Z; Fisher J
J Mater Sci Mater Med; 2006 Mar; 17(3):235-43. PubMed ID: 16555115
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]