These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 23832232)

  • 1. Novel solid-phase extractor based on functionalization of multi-walled carbon nano tubes with 5-aminosalicylic acid for preconcentration of Pb(II) in water samples prior to determination by ICP-OES.
    Soliman EM; Marwani HM; Albishri HM
    Environ Monit Assess; 2013 Dec; 185(12):10269-80. PubMed ID: 23832232
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chemically modified activated carbon with 1-acylthiosemicarbazide for selective solid-phase extraction and preconcentration of trace Cu(II), Hg(II) and Pb(II) from water samples.
    Gao R; Hu Z; Chang X; He Q; Zhang L; Tu Z; Shi J
    J Hazard Mater; 2009 Dec; 172(1):324-9. PubMed ID: 19643535
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of ethylenediamine-grafted multiwalled carbon nanotubes for solid-phase extraction of lead cations.
    Hu ZJ; Cui Y; Liu S; Yuan Y; Gao HW
    Environ Sci Pollut Res Int; 2012 May; 19(4):1237-44. PubMed ID: 22057851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dithizone modified magnetic nanoparticles for fast and selective solid phase extraction of trace elements in environmental and biological samples prior to their determination by ICP-OES.
    Cheng G; He M; Peng H; Hu B
    Talanta; 2012 Jan; 88():507-15. PubMed ID: 22265534
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Solid-phase extraction of Cu, Co and Pb on oxidized single-walled carbon nanotubes and their determination by inductively coupled plasma mass spectrometry.
    Chen S; Liu C; Yang M; Lu D; Zhu L; Wang Z
    J Hazard Mater; 2009 Oct; 170(1):247-51. PubMed ID: 19473762
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Synthesis, characterization and application of ethylenediamine-modified multiwalled carbon nanotubes for selective solid-phase extraction and preconcentration of metal ions.
    Zang Z; Hu Z; Li Z; He Q; Chang X
    J Hazard Mater; 2009 Dec; 172(2-3):958-63. PubMed ID: 19692175
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Column solid phase extraction of iron(III), copper(II), manganese(II) and lead(II) ions food and water samples on multi-walled carbon nanotubes.
    Ozcan SG; Satiroglu N; Soylak M
    Food Chem Toxicol; 2010; 48(8-9):2401-6. PubMed ID: 20570705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tris(2-aminoethyl) amine functionalized silica gel for solid-phase extraction and preconcentration of Cr(III), Cd(II) and Pb(II) from waters.
    Huang X; Chang X; He Q; Cui Y; Zhai Y; Jiang N
    J Hazard Mater; 2008 Aug; 157(1):154-60. PubMed ID: 18295398
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impregnated multiwalled carbon nanotubes as efficient sorbent for the solid phase extraction of trace amounts of heavy metal ions in food and water samples.
    Gouda AA; Al Ghannam SM
    Food Chem; 2016 Jul; 202():409-16. PubMed ID: 26920312
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparation of iminodiacetic acid functionalized multi-walled carbon nanotubes and its application as sorbent for separation and preconcentration of heavy metal ions.
    Wang J; Ma X; Fang G; Pan M; Ye X; Wang S
    J Hazard Mater; 2011 Feb; 186(2-3):1985-92. PubMed ID: 21242030
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Solid phase extraction of Cd, Pb, Ni, Cu, and Zn in environmental samples on multiwalled carbon nanotubes.
    Yilmaz E; Soylak M
    Environ Monit Assess; 2014 Sep; 186(9):5461-8. PubMed ID: 24811365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry.
    Daşbaşı T; Saçmacı Ş; Ülgen A; Kartal Ş
    Food Chem; 2015 May; 174():591-6. PubMed ID: 25529724
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions.
    Tu Z; He Q; Chang X; Hu Z; Gao R; Zhang L; Li Z
    Anal Chim Acta; 2009 Sep; 649(2):252-7. PubMed ID: 19699402
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Synthesis and application of glutaric dihydrazide modified multiwalled carbon nanotubes for selective solid-phase extraction and preconcentration of Cu(II), Zn(II), Ni(II), and Fe(III).
    Tavallali H; Zahmatkesh S; Aalaei M; Abdardideh D
    J AOAC Int; 2012; 95(3):897-902. PubMed ID: 22816280
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Selective dispersive micro solid-phase extraction using oxidized multiwalled carbon nanotubes modified with 1,10-phenanthroline for preconcentration of lead ions.
    Feist B
    Food Chem; 2016 Oct; 209():37-42. PubMed ID: 27173531
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Zincon-modified activated carbon for solid-phase extraction and preconcentration of trace lead and chromium from environmental samples.
    Li Z; Chang X; Hu Z; Huang X; Zou X; Wu Q; Nie R
    J Hazard Mater; 2009 Jul; 166(1):133-7. PubMed ID: 19091464
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Chemically-modified activated carbon with ethylenediamine for selective solid-phase extraction and preconcentration of metal ions.
    Li Z; Chang X; Zou X; Zhu X; Nie R; Hu Z; Li R
    Anal Chim Acta; 2009 Jan; 632(2):272-7. PubMed ID: 19110104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preconcentrations and determinations of copper, nickel and lead in baby food samples employing Coprinus silvaticus immobilized multi-walled carbon nanotube as solid phase sorbent.
    Ozdemir S; Kilinc E; Oner ET
    Food Chem; 2019 Mar; 276():174-179. PubMed ID: 30409581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficient lead preconcentration using two chemically functionalized carbon nanotubes in hyphenated flow injection-flame atomic absorption spectrometry system.
    Bajaj S; Jain V; Sharma N; Tiwari S; Saxena R
    J Chromatogr A; 2021 Feb; 1638():461888. PubMed ID: 33482614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous separation and preconcentration of Cr(III), Cu(II), Cd(II) and Pb(II) from environmental samples prior to inductively coupled plasma optical emission spectrometric determination.
    Zhang L; Li Z; Du X; Li R; Chang X
    Spectrochim Acta A Mol Biomol Spectrosc; 2012 Feb; 86():443-8. PubMed ID: 22115843
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.