These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 23832320)

  • 1. Clinical impact of an adaptive statistical iterative reconstruction algorithm for detection of hypervascular liver tumours using a low tube voltage, high tube current MDCT technique.
    Marin D; Choudhury KR; Gupta RT; Ho LM; Allen BC; Schindera ST; Colsher JG; Samei E; Nelson RC
    Eur Radiol; 2013 Dec; 23(12):3325-35. PubMed ID: 23832320
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 80-kVp CT using Iterative Reconstruction in Image Space algorithm for the detection of hypervascular hepatocellular carcinoma: phantom and initial clinical experience.
    Hur S; Lee JM; Kim SJ; Park JH; Han JK; Choi BI
    Korean J Radiol; 2012; 13(2):152-64. PubMed ID: 22438682
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
    Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E
    Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of radiologists' experience with an adaptive statistical iterative reconstruction algorithm on detection of hypervascular liver lesions and perception of image quality.
    Marin D; Mileto A; Gupta RT; Ho LM; Allen BC; Choudhury KR; Nelson RC
    Abdom Imaging; 2015 Oct; 40(7):2850-60. PubMed ID: 25783958
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low tube voltage intermediate tube current liver MDCT: sinogram-affirmed iterative reconstruction algorithm for detection of hypervascular hepatocellular carcinoma.
    Yu MH; Lee JM; Yoon JH; Baek JH; Han JK; Choi BI; Flohr TG
    AJR Am J Roentgenol; 2013 Jul; 201(1):23-32. PubMed ID: 23789655
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of a model-based, iterative reconstruction algorithm (MBIR) regarding image quality and dose reduction in liver computed tomography.
    Chang W; Lee JM; Lee K; Yoon JH; Yu MH; Han JK; Choi BI
    Invest Radiol; 2013 Aug; 48(8):598-606. PubMed ID: 23511193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality.
    Lv P; Liu J; Zhang R; Jia Y; Gao J
    Korean J Radiol; 2015; 16(3):531-40. PubMed ID: 25995682
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Knowledge-based Iterative Model Reconstruction and Hybrid Reconstruction Techniques for Liver CT Evaluation of Hypervascular Hepatocellular Carcinoma.
    Park HJ; Lee JM; Park SB; Lee JB; Jeong YK; Yoon JH
    J Comput Assist Tomogr; 2016; 40(6):863-871. PubMed ID: 27331929
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Model-based iterative reconstruction versus adaptive statistical iterative reconstruction and filtered back projection in liver 64-MDCT: focal lesion detection, lesion conspicuity, and image noise.
    Shuman WP; Green DE; Busey JM; Kolokythas O; Mitsumori LM; Koprowicz KM; Thibault JB; Hsieh J; Alessio AM; Choi E; Kinahan PE
    AJR Am J Roentgenol; 2013 May; 200(5):1071-6. PubMed ID: 23617492
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.
    Singh S; Kalra MK; Hsieh J; Licato PE; Do S; Pien HH; Blake MA
    Radiology; 2010 Nov; 257(2):373-83. PubMed ID: 20829535
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection--initial clinical experience.
    Marin D; Nelson RC; Samei E; Paulson EK; Ho LM; Boll DT; DeLong DM; Yoshizumi TT; Schindera ST
    Radiology; 2009 Jun; 251(3):771-9. PubMed ID: 19346514
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultra-low-dose CT of the lung: effect of iterative reconstruction techniques on image quality.
    Yanagawa M; Gyobu T; Leung AN; Kawai M; Kawata Y; Sumikawa H; Honda O; Tomiyama N
    Acad Radiol; 2014 Jun; 21(6):695-703. PubMed ID: 24713541
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.
    Lim K; Kwon H; Cho J; Oh J; Yoon S; Kang M; Ha D; Lee J; Kang E
    J Comput Assist Tomogr; 2015; 39(3):443-8. PubMed ID: 25654782
    [TBL] [Abstract][Full Text] [Related]  

  • 14. CT of the pancreas: comparison of image quality and pancreatic duct depiction among model-based iterative, adaptive statistical iterative, and filtered back projection reconstruction techniques.
    Lin XZ; Machida H; Tanaka I; Fukui R; Ueno E; Chen KM; Yan FH
    Abdom Imaging; 2014 Jun; 39(3):497-505. PubMed ID: 24496703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultralow-Dose Abdominal Computed Tomography: Comparison of 2 Iterative Reconstruction Techniques in a Prospective Clinical Study.
    Khawaja RD; Singh S; Blake M; Harisinghani M; Choy G; Karaosmanoglu A; Padole A; Pourjabbar S; Do S; Kalra MK
    J Comput Assist Tomogr; 2015; 39(4):489-98. PubMed ID: 26182223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm.
    Solomon J; Marin D; Roy Choudhury K; Patel B; Samei E
    Radiology; 2017 Sep; 284(3):777-787. PubMed ID: 28170300
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction.
    Son SS; Choo KS; Jeon UB; Jeon GR; Nam KJ; Kim TU; Yeom JA; Hwang JY; Jeong DW; Lim SJ
    Int J Cardiovasc Imaging; 2015 Jun; 31 Suppl 1():31-8. PubMed ID: 25414055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Iterative reconstruction: comparison of techniques for reduced-dose liver computed tomography following transarterial chemoembolization for hepatocellular carcinoma.
    Cha MJ; Jeong WK; Choi D; Kim YK; Lim S; Choi SY; Lee WJ
    Acta Radiol; 2016 Dec; 57(12):1429-1437. PubMed ID: 26792822
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp.
    Kim JH; Choo KS; Moon TY; Lee JW; Jeon UB; Kim TU; Hwang JY; Yun MJ; Jeong DW; Lim SJ
    Eur Radiol; 2016 Jul; 26(7):2055-63. PubMed ID: 26486938
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: does one size fit all?
    Botelho MP; Agrawal R; Gonzalez-Guindalini FD; Hart EM; Patel SK; Töre HG; Yaghmai V
    Eur J Radiol; 2013 Nov; 82(11):e726-33. PubMed ID: 23928232
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.