163 related articles for article (PubMed ID: 23834855)
1. Geometric optimization of a step bearing for a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis.
Kosaka R; Yada T; Nishida M; Maruyama O; Yamane T
Artif Organs; 2013 Sep; 37(9):778-85. PubMed ID: 23834855
[TBL] [Abstract][Full Text] [Related]
2. Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller.
Kosaka R; Nishida M; Maruyama O; Yambe T; Imachi K; Yamane T
Biomed Mater Eng; 2013; 23(1-2):37-47. PubMed ID: 23442235
[TBL] [Abstract][Full Text] [Related]
3. Optimal bearing gap of a multiarc radial bearing in a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis.
Kosaka R; Yasui K; Nishida M; Kawaguchi Y; Maruyama O; Yamane T
Artif Organs; 2014 Sep; 38(9):818-22. PubMed ID: 25234763
[TBL] [Abstract][Full Text] [Related]
4. Improvement of hemocompatibility for hydrodynamic levitation centrifugal pump by optimizing step bearings.
Kosaka R; Yada T; Nishida M; Maruyama O; Yamane T
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1331-4. PubMed ID: 22254562
[TBL] [Abstract][Full Text] [Related]
5. Improvement of hemolysis performance in a hydrodynamically levitated centrifugal blood pump by optimizing a shroud size.
Kosaka R; Sakota D; Nishida M; Maruyama O; Yamane T
J Artif Organs; 2021 Jun; 24(2):157-163. PubMed ID: 33428006
[TBL] [Abstract][Full Text] [Related]
6. Optimal design of the hydrodynamic multi-arc bearing in a centrifugal blood pump for the improvement of bearing stiffness and hemolysis level.
Yasui K; Kosaka R; Nishida M; Maruyama O; Kawaguchi Y; Yamane T
Artif Organs; 2013 Sep; 37(9):768-77. PubMed ID: 23980526
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a Spiral Groove Geometry for Improvement of Hemolysis Level in a Hydrodynamically Levitated Centrifugal Blood Pump.
Murashige T; Kosaka R; Sakota D; Nishida M; Kawaguchi Y; Yamane T; Maruyama O
Artif Organs; 2015 Aug; 39(8):710-4. PubMed ID: 26146791
[TBL] [Abstract][Full Text] [Related]
8. Bearing gap adjustment for improvement of levitation performance in a hydrodynamically levitated centrifugal blood pump.
Kosaka R; Yoshida F; Nishida M; Maruyama O; Kawaguchi Y; Yamane T
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3295-8. PubMed ID: 26736996
[TBL] [Abstract][Full Text] [Related]
9. Fluid dynamic design for low hemolysis in a hydrodynamically levitated centrifugal blood pump.
Murashige T; Kosaka R; Nishida M; Maruyama O; Yamane T; Kuwana K; Kawaguchi Y
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2732-5. PubMed ID: 24110292
[TBL] [Abstract][Full Text] [Related]
10. Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation.
Kosaka R; Maruyama O; Nishida M; Yada T; Saito S; Hirai S; Yamane T
Artif Organs; 2009 Oct; 33(10):798-804. PubMed ID: 19681836
[TBL] [Abstract][Full Text] [Related]
11. Influence of radial clearance and rotor motion to hemolysis in a journal bearing of a centrifugal blood pump.
Kataoka H; Kimura Y; Fujita H; Takatani S
Artif Organs; 2006 Nov; 30(11):841-54. PubMed ID: 17062107
[TBL] [Abstract][Full Text] [Related]
12. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
[TBL] [Abstract][Full Text] [Related]
13. Centrifugal blood pump for temporary ventricular assist devices with low priming and ceramic bearings.
Leme J; da Silva C; Fonseca J; da Silva BU; Uebelhart B; Biscegli JF; Andrade A
Artif Organs; 2013 Nov; 37(11):942-5. PubMed ID: 24219168
[TBL] [Abstract][Full Text] [Related]
14. Improvement of hemolysis in a centrifugal blood pump with hydrodynamic bearings and semi-open impeller.
Kosaka R; Yamane T; Maruyama O; Nishida M; Yada T; Saito S; Hirai S
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3982-5. PubMed ID: 18002872
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of erythrocyte flow at a bearing gap in a hydrodynamically levitated centrifugal blood pump.
Murashige T; Kosaka R; Sakota D; Nishida M; Kawaguchi Y; Yamane T; Maruyama O
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():270-3. PubMed ID: 26736252
[TBL] [Abstract][Full Text] [Related]
16. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.
Leme J; Fonseca J; Bock E; da Silva C; da Silva BU; Dos Santos AE; Dinkhuysen J; Andrade A; Biscegli JF
Artif Organs; 2011 May; 35(5):443-7. PubMed ID: 21595709
[TBL] [Abstract][Full Text] [Related]
17. Numerical simulation of the leakage flow of the hydrodynamically levitated centrifugal blood pump for extracorporeal mechanical circulatory support systems.
Tsukiya T; Nishinaka T
J Artif Organs; 2023 Sep; 26(3):176-183. PubMed ID: 35907152
[TBL] [Abstract][Full Text] [Related]
18. A passive magnetically and hydrodynamically suspended rotary blood pump.
Stoiber M; Grasl C; Pirker S; Raderer F; Schistek R; Huber L; Gittler P; Schima H
Artif Organs; 2009 Mar; 33(3):250-7. PubMed ID: 19245524
[TBL] [Abstract][Full Text] [Related]
19. Hemocompatibility of a hydrodynamic levitation centrifugal blood pump.
Yamane T; Maruyama O; Nishida M; Kosaka R; Sugiyama D; Miyamoto Y; Kawamura H; Kato T; Sano T; Okubo T; Sankai Y; Shigeta O; Tsutsui T
J Artif Organs; 2007; 10(2):71-6. PubMed ID: 17574508
[TBL] [Abstract][Full Text] [Related]
20. Disposable MagLev centrifugal blood pump utilizing a cone-shaped impeller.
Hijikata W; Sobajima H; Shinshi T; Nagamine Y; Wada S; Takatani S; Shimokohbe A
Artif Organs; 2010 Aug; 34(8):669-77. PubMed ID: 20528854
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]