BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 23841344)

  • 21. Quantitative determination of domperidone in human plasma by ultraperformance liquid chromatography with electrospray ionization tandem mass spectrometry.
    Xu DH; Lou HG; Yuan H; Jiang B; Zhou Q; Zhang ZM; Ruan ZR
    Biomed Chromatogr; 2008 Apr; 22(4):433-40. PubMed ID: 18059046
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: application to a bioequivalence study.
    Almeida AA; Campos DR; Bernasconi G; Calafatti S; Barros FA; Eberlin MN; Meurer EC; Paris EG; Pedrazzoli J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Apr; 848(2):311-6. PubMed ID: 17098483
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determination of genkwanin in rat plasma by liquid chromatography-tandem mass spectrometry: application to a bioavailability study.
    Song Y; Zhang S; Liu H; Jin X
    J Pharm Biomed Anal; 2013 Oct; 84():129-34. PubMed ID: 23831487
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Validated LC-MS-MS method for the determination of quetiapine in human plasma: application to a pharmacokinetic study.
    Pan RN; Kuo BP; Pao LH
    J Chromatogr Sci; 2012 Mar; 50(3):277-82. PubMed ID: 22337805
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of cefoperazone and sulbactam in plasma and its application to a pharmacokinetic study.
    Zhou Y; Zhang J; Guo B; Yu J; Shi Y; Wang M; Zhang Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Nov; 878(30):3119-24. PubMed ID: 20971044
    [TBL] [Abstract][Full Text] [Related]  

  • 26. High-throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study.
    Nirogi RV; Kandikere VN; Shukla M; Mudigonda K; Maurya S; Komarneni P
    Rapid Commun Mass Spectrom; 2006; 20(12):1864-70. PubMed ID: 16715478
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Development of a liquid chromatography/tandem mass spectrometry assay for the determination of bestatin in rat plasma and its application to a pharmacokinetic study.
    Wang C; Fan G; Lin M; Chen Y; Zhao W; Wu Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 850(1-2):101-8. PubMed ID: 17141585
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Validation and application of a 96-well format solid-phase extraction and liquid chromatography-tandem mass spectrometry method for the quantitation of digoxin in human plasma.
    Hashimoto Y; Shibakawa K; Nakade S; Miyata Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jun; 869(1-2):126-32. PubMed ID: 18515196
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry.
    Zhao X; Liu Y; Xu J; Zhang D; Zhou Y; Gu J; Cui Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Nov; 877(29):3724-8. PubMed ID: 19782650
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Quantification of pseudoephedrine in human plasma by LC-MS/MS using mosapride as internal standard.
    Nirogi RV; Kandikere VN; Shukla M; Mudigonda K; Maurya S; Komarneni P
    Biomed Chromatogr; 2007 Mar; 21(3):241-8. PubMed ID: 17230461
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development and validation of an LC-ESI-MS method for quantitative determination of aripiprazole in human plasma and an application to pharmacokinetic study.
    Ravinder S; Bapuji AT; Mukkanti K; Raju DR; Ravikiran HL; Reddy DC
    J Chromatogr Sci; 2012; 50(10):893-901. PubMed ID: 22767645
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Determination and pharmacokinetic study of hydrocodone in human plasma by liquid chromatography coupled with tandem mass spectrometry.
    Zhang R; Wang B; Wei C; Yuan G; Guo R
    Artif Cells Blood Substit Immobil Biotechnol; 2009; 37(5):203-7. PubMed ID: 19728188
    [TBL] [Abstract][Full Text] [Related]  

  • 33. High throughput and sensitive determination of trazodone and its primary metabolite, m-chlorophenylpiperazine, in human plasma by liquid chromatography-tandem mass spectrometry.
    Patel BN; Sharma N; Sanyal M; Shrivastav PS
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Aug; 871(1):44-54. PubMed ID: 18621591
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Determination of paroxetine in plasma by liquid chromatography coupled to tandem mass spectrometry for pharmacokinetic and bioequivalence studies.
    Jhee OH; Seo HK; Lee MH; Jeon YC; Shaw LM; Lee SH; Hur Y; Kim KH; Lee HS; Lee SE; Kang JS
    Arzneimittelforschung; 2007; 57(7):455-61. PubMed ID: 17803058
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A rapid and highly sensitive method for the determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a pre-clinical pharmacokinetic study.
    Chakradhar L; Kallem R; Karthik A; Sundari BT; Ramesh S; Mullangi R; Srinivas NR
    Biomed Chromatogr; 2008 Jan; 22(1):58-63. PubMed ID: 17642067
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of aranidipine and its active metabolite in human plasma by liquid chromatography/negative electrospray ionization tandem mass spectrometry.
    Tian L; Jiang J; Huang Y; Xu L; Liu H; Li Y
    Rapid Commun Mass Spectrom; 2006; 20(19):2871-7. PubMed ID: 16941544
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of beraprost in human plasma by a high-performance liquid chromatography-tandem mass spectrometry.
    Lee J; Kim H; Jeong JC; Park ES; Hwang KW; Yang SJ; Jeong JH
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Nov; 859(2):229-33. PubMed ID: 17951119
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microdose clinical trial: quantitative determination of fexofenadine in human plasma using liquid chromatography/electrospray ionization tandem mass spectrometry.
    Yamane N; Tozuka Z; Sugiyama Y; Tanimoto T; Yamazaki A; Kumagai Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Oct; 858(1-2):118-28. PubMed ID: 17804306
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative determination of donepezil in human plasma by liquid chromatography/tandem mass spectrometry employing an automated liquid-liquid extraction based on 96-well format plates. Application to a bioequivalence study.
    Apostolou C; Dotsikas Y; Kousoulos C; Loukas YL
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Apr; 848(2):239-44. PubMed ID: 17113365
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quantification of fexofenadine in human plasma by liquid chromatography coupled to electrospray tandem mass spectrometry using mosapride as internal standard.
    Nirogi RV; Kandikere VN; Shukla M; Mudigonda K; Maurya S; Komarneni P
    Biomed Chromatogr; 2007 Feb; 21(2):209-16. PubMed ID: 17221908
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.