These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 23849890)

  • 61. Sutureless Perceval aortic valve in comparison with the stented Carpentier-Edwards Perimount aortic valve.
    König KC; Wahlers T; Scherner M; Wippermann J
    J Heart Valve Dis; 2014 Mar; 23(2):253-8. PubMed ID: 25076560
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries.
    Ihlberg L; Nissen H; Nielsen NE; Rück A; Busund R; Klaarborg KE; Soendergaard L; Harnek J; Miettinen H; Eskola M; Wahba A; Laine M
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1047-54; discussion 1054. PubMed ID: 23998786
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Integrity of mechanical aortic valve prostheses explanted after 27 and 23 years.
    Winkler B; Inderbitzin DT; Ruppert P; Halbeisen M; Grapow MT; Eckstein FS
    Asian Cardiovasc Thorac Ann; 2013 Jun; 21(3):348-51. PubMed ID: 24570506
    [TBL] [Abstract][Full Text] [Related]  

  • 64. A Case of Infected Mitral-Aortic Intervalvular Fibrosa Pseudoaneurysm.
    Malahfji M; Chamsi-Pasha M; Chang SM
    Methodist Debakey Cardiovasc J; 2018; 14(2):151-152. PubMed ID: 29977474
    [No Abstract]   [Full Text] [Related]  

  • 65. Percutaneous closure of paravalvular leak after transcatheter aortic valve replacement.
    Luu J; Ali O; Feldman TE; Price MJ
    JACC Cardiovasc Interv; 2013 Feb; 6(2):e6-8. PubMed ID: 23428021
    [No Abstract]   [Full Text] [Related]  

  • 66. Pre-dismissal surveillance echocardiography second day after TAVR.
    Iida R; Welsh RC; Meyer SR; Tyrrell BD; Taylor DA; Shanks M
    JACC Cardiovasc Imaging; 2012 Nov; 5(11):1182-4. PubMed ID: 23153920
    [No Abstract]   [Full Text] [Related]  

  • 67. Imaging of prosthetic heart valve dysfunction: complementary diagnostic value of TEE and MDCT?
    Habets J; Tanis W; Mali WP; Chamuleau SA; Budde RP
    JACC Cardiovasc Imaging; 2012 Sep; 5(9):956-61. PubMed ID: 22974809
    [No Abstract]   [Full Text] [Related]  

  • 68. Management of severe aortic regurgitation in a patient with cardiogenic shock using a percutaneous left ventricular assist device and transcatheter occlusion of the failed aortic valve homograft as a bridge to surgical valve replacement.
    Pollak P; Lim DS; Kern J
    Catheter Cardiovasc Interv; 2014 Jan; 83(1):E141-5. PubMed ID: 23674479
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Percutaneous closure of aortic prosthetic paravalvular regurgitation with two amplatzer septal occluders.
    Phillips SA; Thompson A; Abu-Halimah A; Crenshaw MH; Zhao DX; Pretorius M
    Anesth Analg; 2009 Feb; 108(2):437-8. PubMed ID: 19151267
    [No Abstract]   [Full Text] [Related]  

  • 70. Device closure of paravalvular defects following transcatheter aortic valve replacement with the Edwards Sapien valve.
    Whisenant B; Jones K; Horton KD; Horton S
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):901-5. PubMed ID: 22581786
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Transapical aortic valve-in-valve-in-valve implantation as a procedural rescue option.
    Kempfert J; Girrbach F; Haensig M; Subramanian S; Holzhey DM; Mohr FW
    Ann Thorac Surg; 2013 Jan; 95(1):325-8. PubMed ID: 23272851
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy.
    Muratori M; Montorsi P; Maffessanti F; Teruzzi G; Zoghbi WA; Gripari P; Tamborini G; Ghulam Ali S; Fusini L; Fiorentini C; Pepi M
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):196-205. PubMed ID: 23489533
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Built-in defect of a biological pericardial aortic prosthesis?
    Buklas D; Massetti M; Neri E; Chocron S
    Interact Cardiovasc Thorac Surg; 2008 Dec; 7(6):1110-1. PubMed ID: 18550605
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Short-term follow up with the 3f Enable aortic bioprosthesis: clinical and echocardiographic results.
    Concistrè G; Miceli A; Marchi F; Farneti P; Chiaramonti F; Solinas M; Glauber AG
    J Heart Valve Dis; 2013 Nov; 22(6):817-23. PubMed ID: 24597403
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.
    Seiffert M; Bader R; Kappert U; Rastan A; Krapf S; Bleiziffer S; Hofmann S; Arnold M; Kallenbach K; Conradi L; Schlingloff F; Wilbring M; Schäfer U; Diemert P; Treede H
    JACC Cardiovasc Interv; 2014 Oct; 7(10):1168-74. PubMed ID: 25129672
    [TBL] [Abstract][Full Text] [Related]  

  • 76. The Mosaic porcine bioprosthesis: role of age on clinical performance in aortic position.
    Riess FC; Bader R; Cramer E; Hansen L; Schiffelers S; Wallrath J; Wahl G
    J Thorac Cardiovasc Surg; 2011 Jun; 141(6):1440-8.e1. PubMed ID: 20850804
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Fracturing the Ring of Small Mitroflow Bioprostheses by High-Pressure Balloon Predilatation in Transcatheter Aortic Valve-in-Valve Implantation.
    Nielsen-Kudsk JE; Christiansen EH; Terkelsen CJ; Nørgaard BL; Jensen KT; Krusell LR; Tang M; Terp K; Klaaborg KE; Andersen HR
    Circ Cardiovasc Interv; 2015 Aug; 8(8):e002667. PubMed ID: 26208503
    [No Abstract]   [Full Text] [Related]  

  • 78. Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.
    Husser O; Rauch S; Endemann DH; Resch M; Nunez J; Bodi V; Hilker M; Schmid C; Riegger GA; Luchner A; Hengstenberg C
    Catheter Cardiovasc Interv; 2012 Nov; 80(6):956-63. PubMed ID: 22419651
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Structural valve failure with every beat regurgitation observed using the Medtronic Advantage aortic valve.
    Hansen L; Danne M; Hoffmann B; Riess FC
    J Thorac Cardiovasc Surg; 2007 Nov; 134(5):1344-5. PubMed ID: 17976473
    [No Abstract]   [Full Text] [Related]  

  • 80. Strategy to avoid patient-prosthesis mismatch: aortic root enlargement.
    Srivastava DK; Sanki P; Bhattacharya S; Siddique JV
    Asian Cardiovasc Thorac Ann; 2014 Feb; 22(2):137-41. PubMed ID: 24585782
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.