These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 23850758)

  • 1. A 10-b 50-MS/s 820- μW SAR ADC With On-Chip Digital Calibration.
    Yoshioka M; Ishikawa K; Takayama T; Tsukamoto S
    IEEE Trans Biomed Circuits Syst; 2010 Dec; 4(6):410-6. PubMed ID: 23850758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A 1.15 μW 200 kS/s 10-b Monotonic SAR ADC Using Dual On-Chip Calibrations and Accuracy Enhancement Techniques.
    Lee JH; Park D; Cho W; Phan HN; Nguyen CL; Lee JW
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30332815
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An 11.8-fJ/Conversion-Step Noise Shaping SAR ADC with Embedded Passive Gain for Energy-Efficient IoT Sensors.
    Choi C; Lee JW
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 0.3V 10b 3MS/s SAR ADC With Comparator Calibration and Kickback Noise Reduction for Biomedical Applications.
    Wang SH; Hung CC
    IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):558-569. PubMed ID: 32224463
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 1.33 μW 8.02-ENOB 100 kS/s successive approximation ADC with supply reduction technique for implantable retinal prosthesis.
    Tang H; Sun ZC; Chew KW; Siek L
    IEEE Trans Biomed Circuits Syst; 2014 Dec; 8(6):844-56. PubMed ID: 25608284
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A 10-Bit 400-KS/s Low Noise Asynchronous SAR ADC with Dual-Domain Comparator for Input-Referred Noise Reduction.
    Lee SH; Lee WY
    Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015841
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 12-b Subranging SAR ADC Using Detect-and-Skip Switching and Mismatch Calibration for Biopotential Sensing Applications.
    Nguyen CL; Phan HN; Lee JW
    Sensors (Basel); 2022 May; 22(9):. PubMed ID: 35591288
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fully integrated low-noise readout circuit with automatic offset cancellation loop for capacitive microsensors.
    Song H; Park Y; Kim H; Cho DI; Ko H
    Sensors (Basel); 2015 Oct; 15(10):26009-17. PubMed ID: 26473877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A 14-b 20-MS/s 78.8 dB-SNDR Energy-Efficient SAR ADC With Background Mismatch Calibration and Noise-Reduction Techniques for Portable Medical Ultrasound Systems.
    Liang Y; Li C; Liu S; Zhu Z
    IEEE Trans Biomed Circuits Syst; 2022 Apr; 16(2):200-210. PubMed ID: 35104226
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 14-Bit Hybrid Analog-to-Digital Converter for Infrared Focal Plane Array Digital Readout Integrated Circuit.
    Hu D; Yao L; Chen N; Zhang J; Zhong S; Mao W; Zhu F; Zhang J
    Sensors (Basel); 2024 Jun; 24(11):. PubMed ID: 38894443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A 13-bit Noise Shaping SAR-ADC with Dual-Polarity Digital Calibration.
    Park H; Ghovanloo M
    Analog Integr Circuits Signal Process; 2013 Jun; 75(3):459-465. PubMed ID: 23682207
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A 7.6-nW 1-kS/s 10-Bit SAR ADC for Biomedical Applications.
    Hu Y; Tang B; Hu L; Liang H; Li B; Wu Z; Liu X
    Micromachines (Basel); 2022 Nov; 13(12):. PubMed ID: 36557409
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Design of 10-Bit Asynchronous SAR ADC with an On-Chip Bandgap Reference Voltage Generator.
    Verma D; Shehzad K; Kim SJ; Pu YG; Yoo SS; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35891072
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices.
    Yang Y; Zhou J; Liu X; Goh WL
    Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 29970814
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A 12-bit high-speed column-parallel two-step single-slope analog-to-digital converter (ADC) for CMOS image sensors.
    Lyu T; Yao S; Nie K; Xu J
    Sensors (Basel); 2014 Nov; 14(11):21603-25. PubMed ID: 25407903
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A cryogenic analog to digital converter operating from 300 K down to 4.4 K.
    Okcan B; Merken P; Gielen G; Van Hoof C
    Rev Sci Instrum; 2010 Feb; 81(2):024702. PubMed ID: 20192509
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 1.72μW, 23.2fj/conversion step successive approach ADC for bio-medical signal acquisition.
    Wang WS; Tang KT
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2703-6. PubMed ID: 22254899
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Low-Power 12-Bit 20 MS/s Asynchronously Controlled SAR ADC for WAVE ITS Sensor Based Applications.
    Shehzad K; Verma D; Khan D; Ain QU; Basim M; Kim SJ; Rikan BS; Pu YG; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2021 Mar; 21(7):. PubMed ID: 33804902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Low-Power SAR ADC with Capacitor-Splitting Energy-Efficient Switching Scheme for Wearable Biosensor Applications.
    Hu Y; Huang Q; Tang B; Chen C; Hu L; Yu E; Li B; Wu Z
    Micromachines (Basel); 2023 Dec; 14(12):. PubMed ID: 38138413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-power circuits for the bidirectional wireless monitoring system of the orthopedic implants.
    Hong Chen ; Ming Liu ; Wenhan Hao ; Yi Chen ; Chen Jia ; Chun Zhang ; Zihua Wang
    IEEE Trans Biomed Circuits Syst; 2009 Dec; 3(6):437-43. PubMed ID: 23853291
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.