  • 1. Energy efficient low-noise neural recording amplifier with enhanced noise efficiency factor.
    Majidzadeh V; Schmid A; Leblebici Y
    IEEE Trans Biomed Circuits Syst; 2011 Jun; 5(3):262-71. PubMed ID: 23851477
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An energy-efficient micropower neural recording amplifier.
    Wattanapanitch W; Fee M; Sarpeshkar R
    IEEE Trans Biomed Circuits Syst; 2007 Jun; 1(2):136-47. PubMed ID: 23851668
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Power Efficient Low-noise and High Swing CMOS Amplifier for Neural Recording Applications.
    Naderi K; Shad E; Molinas M; Heidari A
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():4298-4301. PubMed ID: 33018946
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor.
    Tzu-Yun Wang ; Min-Rui Lai ; Twigg CM; Sheng-Yu Peng
    IEEE Trans Biomed Circuits Syst; 2014 Jun; 8(3):411-22. PubMed ID: 24108476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A compact, low input capacitance neural recording amplifier.
    Ng KA; Xu YP
    IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):610-20. PubMed ID: 24144666
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A low-power configurable neural recording system for epileptic seizure detection.
    Qian C; Shi J; Parramon J; Sánchez-Sinencio E
    IEEE Trans Biomed Circuits Syst; 2013 Aug; 7(4):499-512. PubMed ID: 23893209
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A low-power 32-channel digitally programmable neural recording integrated circuit.
    Wattanapanitch W; Sarpeshkar R
    IEEE Trans Biomed Circuits Syst; 2011 Dec; 5(6):592-602. PubMed ID: 23852555
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fully integrated neural recording amplifier with DC input stabilization.
    Mohseni P; Najafi K
    IEEE Trans Biomed Eng; 2004 May; 51(5):832-7. PubMed ID: 15132510
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Power-to-Noise Optimization in the Design of Neural Recording Amplifier Based on Current Scaling, Source Degeneration Resistor, and Current Reuse.
    Wang Z; Wang X; Shu G; Yin M; Huang S; Yin M
    Biosensors (Basel); 2024 Feb; 14(2):. PubMed ID: 38392030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Low Noise Amplifier for Neural Spike Recording Interfaces.
    Ruiz-Amaya J; Rodriguez-Perez A; Delgado-Restituto M
    Sensors (Basel); 2015 Sep; 15(10):25313-35. PubMed ID: 26437411
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of ultra-low power biopotential amplifiers for biosignal acquisition applications.
    Zhang F; Holleman J; Otis BP
    IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):344-55. PubMed ID: 23853179
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A low-power integrated bioamplifier with active low-frequency suppression.
    Gosselin B; Sawan M; Chapman CA
    IEEE Trans Biomed Circuits Syst; 2007 Sep; 1(3):184-92. PubMed ID: 23852412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A tunable biquad switched-capacitor amplifier-filter for neural recording.
    Jongwoo Lee ; Johnson MD; Kipke DR
    IEEE Trans Biomed Circuits Syst; 2010 Oct; 4(5):295-300. PubMed ID: 23853375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variable-gain, low-noise amplification for sampling front ends.
    Rieger R
    IEEE Trans Biomed Circuits Syst; 2011 Jun; 5(3):253-61. PubMed ID: 23851476
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Low-Power Current-Reuse Analog Front-End for High-Density Neural Recording Implants.
    Rezaei M; Maghsoudloo E; Bories C; De Koninck Y; Gosselin B
    IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):271-280. PubMed ID: 29570055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An 11 μ w, two-electrode transimpedance biosignal amplifier with active current feedback stabilization.
    Inan OT; Kovacs GT
    IEEE Trans Biomed Circuits Syst; 2010 Apr; 4(2):93-100. PubMed ID: 23853316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A digitally assisted, signal folding neural recording amplifier.
    Chen Y; Basu A; Liu L; Zou X; Rajkumar R; Dawe GS; Je M
    IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):528-42. PubMed ID: 25073128
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording.
    Wu CY; Chen WM; Kuo LT
    IEEE Trans Biomed Circuits Syst; 2013 Apr; 7(2):107-14. PubMed ID: 23853293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Low-Noise, Low-Power Amplifier With Current-Reused OTA for ECG Recordings.
    Zhang J; Zhang H; Sun Q; Zhang R
    IEEE Trans Biomed Circuits Syst; 2018 Jun; 12(3):700-708. PubMed ID: 29877832
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-Cutoff Frequency Reduction in Neural Amplifiers: Analysis and Implementation in CMOS 65 nm.
    Hashemi Noshahr F; Nabavi M; Gosselin B; Sawan M
    Front Neurosci; 2021; 15():667846. PubMed ID: 34149347
    [TBL] [Abstract][Full Text] [Related]  