These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 23852410)

  • 1. A nanopower bandpass filter for detection of an acoustic signal in a wearable breathing detector.
    Corbishley P; Rodriguez-Villegas E
    IEEE Trans Biomed Circuits Syst; 2007 Sep; 1(3):163-71. PubMed ID: 23852410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 0.5 V, nW-Range Universal Filter Based on Multiple-Input Transconductor for Biosignals Processing.
    Khateb F; Kumngern M; Kulej T; Akbari M; Stopjakova V
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433216
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Systematic Design and Modeling of a OTA-C Filter for Portable ECG Detection.
    Shuenn-Yuh Lee ; Chih-Jen Cheng
    IEEE Trans Biomed Circuits Syst; 2009 Feb; 3(1):53-64. PubMed ID: 23853163
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Low-Voltage OTA-C Filter With an Area- and Power-Efficient OTA for Biosignal Sensor Applications.
    Lee SY; Wang CP; Chu YS
    IEEE Trans Biomed Circuits Syst; 2019 Feb; 13(1):56-67. PubMed ID: 30475730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Low-Power CMOS Front-End for Photoplethysmographic Signal Acquisition With Robust DC Photocurrent Rejection.
    Wong AK; Kong-Pang Pun ; Yuan-Ting Zhang ; Ka Nang Leung
    IEEE Trans Biomed Circuits Syst; 2008 Dec; 2(4):280-8. PubMed ID: 23853131
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A low-power wide-range I-v converter for amperometric sensing applications.
    Rodriguez-Villegas E
    IEEE Trans Biomed Circuits Syst; 2009 Dec; 3(6):432-6. PubMed ID: 23853290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low-Power Sensor Interface with a Switched Inductor Frequency Selective Envelope Detector.
    Gazivoda M; Bilas V
    Sensors (Basel); 2021 Mar; 21(6):. PubMed ID: 33803536
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 0.5 V Fifth-Order Butterworth Low-Pass Filter Using Multiple-Input OTA for ECG Applications.
    Kumngern M; Aupithak N; Khateb F; Kulej T
    Sensors (Basel); 2020 Dec; 20(24):. PubMed ID: 33371335
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A low power MICS band phase-locked loop for high resolution retinal prosthesis.
    Yang J; Skafidas E
    IEEE Trans Biomed Circuits Syst; 2013 Aug; 7(4):513-25. PubMed ID: 23893210
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A highly linear fully integrated powerline filter for biopotential acquisition systems.
    Alzaher HA; Tasadduq N; Mahnashi Y
    IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):703-12. PubMed ID: 24232631
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 0.342 nW Class-AB enhanced flipped source follower low pass filter for biomedical applications.
    Thakur D; Sharma K
    Rev Sci Instrum; 2022 Nov; 93(11):114709. PubMed ID: 36461428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low-power low-voltage current readout circuit for inductively powered implant system.
    Haider MR; Islam SK; Mostafa S; Mo Zhang ; Taeho Oh
    IEEE Trans Biomed Circuits Syst; 2010 Aug; 4(4):205-13. PubMed ID: 23853366
    [TBL] [Abstract][Full Text] [Related]  

  • 13. W-band waveguide bandpass filter with E-plane cut.
    Furtula V; Salewski M
    Rev Sci Instrum; 2014 Jul; 85(7):074703. PubMed ID: 25085158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Superconducting nanowire single photon detector with on-chip bandpass filter.
    Yang X; Li H; Zhang W; You L; Zhang L; Liu X; Wang Z; Peng W; Xie X; Jiang M
    Opt Express; 2014 Jun; 22(13):16267-72. PubMed ID: 24977877
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Low Power Linear Phase Programmable Long Delay Circuit.
    Rodriguez-Villegas E; Logesparan L; Casson AJ
    IEEE Trans Biomed Circuits Syst; 2014 Jun; 8(3):432-41. PubMed ID: 24021654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fully integrated neural recording amplifier with DC input stabilization.
    Mohseni P; Najafi K
    IEEE Trans Biomed Eng; 2004 May; 51(5):832-7. PubMed ID: 15132510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Note: characterization of CaF2/acetone bandpass photon detector with Kr filter gas.
    Maniraj M; Raja Sekhar BN; Barman SR
    Rev Sci Instrum; 2012 Apr; 83(4):046107. PubMed ID: 22559593
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low power switched-resistor band-pass filter for neural recording channels in 130nm CMOS.
    Centurelli F; Fava A; MonsurrĂ² P; Scotti G; Tommasino P; Trifiletti A
    Heliyon; 2020 Aug; 6(8):e04723. PubMed ID: 32904287
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Switchable microwave photonic filter between high Q bandpass filter and notch filter with flat passband based on phase modulation.
    Yu Y; Xu E; Dong J; Zhou L; Li X; Zhang X
    Opt Express; 2010 Nov; 18(24):25271-82. PubMed ID: 21164875
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An Auto-Tuning Continuous-Time Bandpass Sigma-Delta Modulator with Signal Observation for MEMS Gyroscope Readout Systems.
    Ju C; Li X; Zou J; Wei Q; Zhou B; Zhang R
    Sensors (Basel); 2020 Apr; 20(7):. PubMed ID: 32244702
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.