These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
174 related articles for article (PubMed ID: 23852924)
1. A comparison of the stress corrosion cracking susceptibility of commercially pure titanium grade 4 in Ringer's solution and in distilled water: a fracture mechanics approach. Roach MD; Williamson RS; Thomas JA; Griggs JA; Zardiackas LD J Biomed Mater Res B Appl Biomater; 2014 Jan; 102(1):73-9. PubMed ID: 23852924 [TBL] [Abstract][Full Text] [Related]
2. Tribological properties of Ti-based alloys in a simulated bone-implant interface with Ringer's solution at fretting contacts. Ramos-Saenz CR; Sundaram PA; Diffoot-Carlo N J Mech Behav Biomed Mater; 2010 Nov; 3(8):549-58. PubMed ID: 20826360 [TBL] [Abstract][Full Text] [Related]
3. Corrosion behavior of dental alloys coupled with titanium. Part 2. The area ratio dependence in five solutions. Nakayama M; Ando N Dent Mater J; 2001 Mar; 20(1):75-89. PubMed ID: 11441490 [TBL] [Abstract][Full Text] [Related]
4. Nanoscale surface modification of a prosthetic material: case of Ti6Al4V into Ringer's solution. Drevet R; Nzoghé-Mendome L; Benhayoune H; Ebothé J J Nanosci Nanotechnol; 2012 Jun; 12(6):4956-61. PubMed ID: 22905558 [TBL] [Abstract][Full Text] [Related]
5. Cyclic fatigue-crack propagation in sapphire in air and simulated physiological environments. Asoo B; McNaney JM; Mitamura Y; Ritchie RO J Biomed Mater Res; 2000 Dec; 52(3):488-91. PubMed ID: 11007616 [TBL] [Abstract][Full Text] [Related]
6. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution. Montero-Ocampo C; Lopez H; Salinas Rodriguez A J Biomed Mater Res; 1996 Dec; 32(4):583-91. PubMed ID: 8953148 [TBL] [Abstract][Full Text] [Related]
7. Galvanic couples of 316L steel with Ti and ion plated Ti and TiN coatings in Ringer's solutions. Gluszek J; Jedrkowiak J; Markowski J; Masalski J Biomaterials; 1990 Jul; 11(5):330-5. PubMed ID: 2400799 [TBL] [Abstract][Full Text] [Related]
8. Corrosion evaluation of Ti-48Al-2Cr-2Nb (at.%) in Ringer's solution. Delgado-Alvarado C; Sundaram PA Acta Biomater; 2006 Nov; 2(6):701-8. PubMed ID: 16887397 [TBL] [Abstract][Full Text] [Related]
9. SEM observations on stress corrosion cracking of commercially pure titanium in a topical fluoride solution. Könönen MH; Lavonius ET; Kivilahti JK Dent Mater; 1995 Jul; 11(4):269-72. PubMed ID: 8621050 [TBL] [Abstract][Full Text] [Related]
10. Electrochemical characteristics of bioresorbable binary MgCa alloys in Ringer's solution: Revealing the impact of local pH distributions during in-vitro dissolution. Mareci D; Bolat G; Izquierdo J; Crimu C; Munteanu C; Antoniac I; Souto RM Mater Sci Eng C Mater Biol Appl; 2016 Mar; 60():402-410. PubMed ID: 26706546 [TBL] [Abstract][Full Text] [Related]
11. The influence of static stress on the corrosion behavior of 316L stainless steel in Ringer's solution. Bundy KJ; Vogelbaum MA; Desai VH J Biomed Mater Res; 1986 Apr; 20(4):493-505. PubMed ID: 3700443 [TBL] [Abstract][Full Text] [Related]
12. In vivo and in vitro studies of the stress-corrosion cracking behavior of surgical implant alloys. Bundy KJ; Marek M; Hochman RF J Biomed Mater Res; 1983 May; 17(3):467-87. PubMed ID: 6863350 [TBL] [Abstract][Full Text] [Related]
13. Corrosion and tarnish of dental silver-based alloys in 0.1% Na2S and Ringer's solutions. (Part 1) Electrochemical study. Endo K; Araki Y; Ohno H Dent Mater J; 1989 Jun; 8(1):46-55. PubMed ID: 2638961 [TBL] [Abstract][Full Text] [Related]
14. Corrosion analysis of NiCu and PdCo thermal seed alloys used as interstitial hyperthermia implants. Paulus JA; Parida GR; Tucker RD; Park JB Biomaterials; 1997 Dec; 18(24):1609-14. PubMed ID: 9613808 [TBL] [Abstract][Full Text] [Related]
15. Influence of strain on the corrosion of magnesium alloys and zinc in physiological environments. Törne K; Örnberg A; Weissenrieder J Acta Biomater; 2017 Jan; 48():541-550. PubMed ID: 27780765 [TBL] [Abstract][Full Text] [Related]
16. Effects of pH and elevated glucose levels on the electrochemical behavior of dental implants. Tamam E; Turkyilmaz I J Oral Implantol; 2014 Apr; 40(2):153-9. PubMed ID: 24779948 [TBL] [Abstract][Full Text] [Related]
17. Effect of immersion time on the passive and electrochemical response of annealed and nano-grained commercial pure titanium in Ringer's physiological solution at 37°C. Fattah-Alhosseini A; Ansari AR; Mazaheri Y; Keshavarz MK Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():771-779. PubMed ID: 27987772 [TBL] [Abstract][Full Text] [Related]
18. Corrosion behavior of titanium boride composite coating fabricated on commercially pure titanium in Ringer's solution for bioimplant applications. Sivakumar B; Singh R; Pathak LC Mater Sci Eng C Mater Biol Appl; 2015 Mar; 48():243-55. PubMed ID: 25579920 [TBL] [Abstract][Full Text] [Related]
19. Influence of corrosion on brazed joints' strength. Angelini E; Pezzoli M; Rosalbino F; Zucchi F J Dent; 1991 Feb; 19(1):56-61. PubMed ID: 1673131 [TBL] [Abstract][Full Text] [Related]
20. Electrochemical corrosion of titanium and titanium-based alloys. Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]