These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
450 related articles for article (PubMed ID: 23853325)
1. A low-power 13.56 MHz RF front-end circuit for implantable biomedical devices. Lee SY; Hong JH; Hsieh CH; Liang MC; Kung JY IEEE Trans Biomed Circuits Syst; 2013 Jun; 7(3):256-65. PubMed ID: 23853325 [TBL] [Abstract][Full Text] [Related]
2. A high-efficiency low-voltage CMOS rectifier for harvesting energy in implantable devices. Hashemi SS; Sawan M; Savaria Y IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):326-35. PubMed ID: 23853177 [TBL] [Abstract][Full Text] [Related]
3. Toward a fully integrated neurostimulator with inductive power recovery front-end. Mounaïm F; Sawan M IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):309-18. PubMed ID: 23853175 [TBL] [Abstract][Full Text] [Related]
4. Wireless front-end with power management for an implantable cardiac microstimulator. Lee SY; Hsieh CH; Yang CM IEEE Trans Biomed Circuits Syst; 2012 Feb; 6(1):28-38. PubMed ID: 23852742 [TBL] [Abstract][Full Text] [Related]
5. A complete data and power telemetry system utilizing BPSK and LSK signaling for biomedical implants. Sonkusale S; Luo Z Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3216-9. PubMed ID: 19163391 [TBL] [Abstract][Full Text] [Related]
6. Low-power transceiver analog front-end circuits for bidirectional high data rate wireless telemetry in medical endoscopy applications. Chi B; Yao J; Han S; Xie X; Li G; Wang Z IEEE Trans Biomed Eng; 2007 Jul; 54(7):1291-9. PubMed ID: 17605360 [TBL] [Abstract][Full Text] [Related]
7. A novel wireless power and data transmission AC to DC converter for an implantable device. Liu JY; Tang KT Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1875-8. PubMed ID: 24110077 [TBL] [Abstract][Full Text] [Related]
8. Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges. Hannan MA; Hussein HA; Mutashar S; Samad SA; Hussain A Sensors (Basel); 2014 Dec; 14(12):23843-70. PubMed ID: 25615728 [TBL] [Abstract][Full Text] [Related]
9. A 2.4 GHz ULP reconfigurable asymmetric transceiver for single-chip wireless neural recording IC. Tan J; Liew WS; Heng CH; Lian Y IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):497-509. PubMed ID: 25073126 [TBL] [Abstract][Full Text] [Related]
10. A photovoltaic-driven and energy-autonomous CMOS implantable sensor. Ayazian S; Akhavan VA; Soenen E; Hassibi A IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):336-43. PubMed ID: 23853178 [TBL] [Abstract][Full Text] [Related]
11. A Single-Chip Full-Duplex High Speed Transceiver for Multi-Site Stimulating and Recording Neural Implants. Mirbozorgi SA; Bahrami H; Sawan M; Rusch LA; Gosselin B IEEE Trans Biomed Circuits Syst; 2016 Jun; 10(3):643-53. PubMed ID: 26469635 [TBL] [Abstract][Full Text] [Related]
12. A Programmable Implantable Microstimulator SoC With Wireless Telemetry: Application in Closed-Loop Endocardial Stimulation for Cardiac Pacemaker. Shuenn-Yuh Lee ; Su MY; Ming-Chun Liang ; You-Yin Chen ; Cheng-Han Hsieh ; Chung-Min Yang ; Hsin-Yi Lai ; Jou-Wei Lin ; Qiang Fang IEEE Trans Biomed Circuits Syst; 2011 Dec; 5(6):511-22. PubMed ID: 23852549 [TBL] [Abstract][Full Text] [Related]
13. A flexible super-capacitive solid-state power supply for miniature implantable medical devices. Meng C; Gall OZ; Irazoqui PP Biomed Microdevices; 2013 Dec; 15(6):973-83. PubMed ID: 23832644 [TBL] [Abstract][Full Text] [Related]
14. An Inductive Power and Data Telemetry Subsystem With Fast Transient Low Dropout Regulator for Biomedical Implants. Lin YP; Tang KT IEEE Trans Biomed Circuits Syst; 2016 Apr; 10(2):435-44. PubMed ID: 26285218 [TBL] [Abstract][Full Text] [Related]
15. A remotely powered implantable biomedical system with location detector. Kilinc EG; Ghanad MA; Maloberti F; Dehollain C IEEE Trans Biomed Circuits Syst; 2015 Feb; 9(1):113-23. PubMed ID: 24988596 [TBL] [Abstract][Full Text] [Related]
16. A low-power noncoherent BPSK demodulator and clock recovery circuit for high-data-rate biomedical applications. Asgarian F; Sodagar AM Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4840-3. PubMed ID: 19963861 [TBL] [Abstract][Full Text] [Related]
17. Micropower circuits for bidirectional wireless telemetry in neural recording applications. Neihart NM; Harrison RR IEEE Trans Biomed Eng; 2005 Nov; 52(11):1950-9. PubMed ID: 16285399 [TBL] [Abstract][Full Text] [Related]
18. An Integrated Wireless Power Management and Data Telemetry IC for High-Compliance-Voltage Electrical Stimulation Applications. Zhao J; Yao L; Xue RF; Li P; Je M; Xu YP IEEE Trans Biomed Circuits Syst; 2016 Feb; 10(1):113-24. PubMed ID: 25910251 [TBL] [Abstract][Full Text] [Related]
19. A mm-sized wirelessly powered and remotely controlled locomotive implant. Pivonka D; Yakovlev A; Poon AS; Meng T IEEE Trans Biomed Circuits Syst; 2012 Dec; 6(6):523-32. PubMed ID: 23853253 [TBL] [Abstract][Full Text] [Related]
20. Inductive and ultrasonic multi-tier interface for low-power, deeply implantable medical devices. Sanni A; Vilches A; Toumazou C IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):297-308. PubMed ID: 23853174 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]