These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
89 related articles for article (PubMed ID: 23858746)
1. [Evaluation of anomalous pulmonary venous connection: comparison between dual-source CT and echocardiography]. Xu Z; Yu J; Li X; Chen D; Luo Y; Peng L Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Apr; 30(2):272-7, 311. PubMed ID: 23858746 [TBL] [Abstract][Full Text] [Related]
2. Preoperative evaluation of anomalous pulmonary venous connection using dual-source computed tomography: Comparison with echocardiography. Jiang L; Xie LJ; Yang ZG; Shi K; Xu HY; Li R; Diao KY; Guo YK Eur J Radiol; 2017 Sep; 94():107-114. PubMed ID: 28669428 [TBL] [Abstract][Full Text] [Related]
3. Quantitative analysis of pulmonary artery and pulmonary collaterals in preoperative patients with pulmonary artery atresia using dual-source computed tomography. Yin L; Lu B; Han L; Wu RZ; Johnson L; Xu ZY; Jiang SL; Dai RP Eur J Radiol; 2011 Sep; 79(3):480-5. PubMed ID: 20627639 [TBL] [Abstract][Full Text] [Related]
4. Role of MDCT angiography in the preoperative evaluation of anomalous pulmonary venous connection associated with complex cardiac abnormality. Liu J; Wu Q; Xu Y; Bai Y; Liu Z; Li H; Zhu J Eur J Radiol; 2012 May; 81(5):1050-6. PubMed ID: 21371843 [TBL] [Abstract][Full Text] [Related]
5. Diagnostic tools in the preoperative evaluation of children with anomalous pulmonary venous connections. Uçar T; Fitoz S; Tutar E; Atalay S; Uysalel A Int J Cardiovasc Imaging; 2008 Feb; 24(2):229-35. PubMed ID: 17597422 [TBL] [Abstract][Full Text] [Related]
6. Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta. Xu J; Zhao H; Wang X; Bai Y; Liu L; Liu Y; Wei M; Li J; Zheng M Acad Radiol; 2014 Oct; 21(10):1248-54. PubMed ID: 25097011 [TBL] [Abstract][Full Text] [Related]
7. [Total anomalous pulmonary venous connection: a 17-years experience of a single pediatric cardiology center]. Ferreira MS; Carvalho N; Teixeira A; Nogueira G; Marques M; Abecassis M; Neves J; Anjos R Rev Port Cir Cardiotorac Vasc; 2012; 19(1):11-6. PubMed ID: 23641468 [TBL] [Abstract][Full Text] [Related]
8. Assessment of tetralogy of Fallot-associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography. Hu BY; Shi K; Deng YP; Diao KY; Xu HY; Li R; Yang ZG; Guo YK BMC Cardiovasc Disord; 2017 Dec; 17(1):285. PubMed ID: 29202750 [TBL] [Abstract][Full Text] [Related]
9. Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography. Shi K; Yang ZG; Chen J; Zhang G; Xu HY; Guo YK PLoS One; 2015; 10(6):e0130987. PubMed ID: 26115034 [TBL] [Abstract][Full Text] [Related]
10. Isolated Partial Anomalous Pulmonary Veins: A 10-Year Experience at a Single Center. Jin C; Wu Y; Wang Z; Liu X; Wang Q J Surg Res; 2024 Jun; 298():63-70. PubMed ID: 38574463 [TBL] [Abstract][Full Text] [Related]
11. Sensitivity of High-Pitch Dual-Source Computed Tomography for the Detection of Anomalous Pulmonary Venous Connection in Infants. Well L; Weinrich JM; Meyer M; Kehl T; Salamon J; Rüffer A; Adam G; Herrmann J; Groth M Rofo; 2021 May; 193(5):551-558. PubMed ID: 33302310 [TBL] [Abstract][Full Text] [Related]
12. Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children. Nie P; Yang G; Wang X; Duan Y; Xu W; Li H; Cao T; Liu X; Ji X; Cheng Z; Wang A PLoS One; 2014; 9(12):e115793. PubMed ID: 25546178 [TBL] [Abstract][Full Text] [Related]
13. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease. Bak SH; Ko SM; Jeon HJ; Yang HS; Hwang HK; Song MG Acta Radiol; 2012 Apr; 53(3):270-7. PubMed ID: 22319133 [TBL] [Abstract][Full Text] [Related]
14. Use of 64 slice CT in scimitar syndrome. Bhupali AN; Kumar J; Patil JK; Chitnis NS; Prasad S J Assoc Physicians India; 2010 Nov; 58():698-700. PubMed ID: 21510466 [TBL] [Abstract][Full Text] [Related]
15. Dual-source Computed Tomography for Evaluating Pulmonary Artery and Aorta in Pediatric Patients with Single Ventricle. Yang MX; Yang ZG; Zhang Y; Shi K; Xu HY; Diao KY; Guo YK Sci Rep; 2017 Oct; 7(1):13398. PubMed ID: 29042577 [TBL] [Abstract][Full Text] [Related]
16. Partial anomalous pulmonary venous connection (including scimitar syndrome). van de Woestijne PC; Verberkmoes N; Bogers AJ Multimed Man Cardiothorac Surg; 2013; 2013():mmt001. PubMed ID: 24413000 [TBL] [Abstract][Full Text] [Related]
18. Comparison study of echocardiography and dual-source CT in diagnosis of coronary artery aneurysm due to Kawasaki disease: coronary artery disease. Yu Y; Sun K; Wang R; Li Y; Xue H; Yu L; Chen S; Xi L Echocardiography; 2011 Oct; 28(9):1025-34. PubMed ID: 21854436 [TBL] [Abstract][Full Text] [Related]
19. Coronary artery fistula in adults: evaluation with dual-source CT coronary angiography. Zhou K; Kong L; Wang Y; Li S; Song L; Wang Z; Wu W; Chen J; Wang Y; Jin Z Br J Radiol; 2015 May; 88(1049):20140754. PubMed ID: 25784320 [TBL] [Abstract][Full Text] [Related]
20. Comparison of dual-source computed tomography for the quantification of the aortic valve area in patients with aortic stenosis versus transthoracic echocardiography and invasive hemodynamic assessment. Ropers D; Ropers U; Marwan M; Schepis T; Pflederer T; Wechsel M; Klinghammer L; Flachskampf FA; Daniel WG; Achenbach S Am J Cardiol; 2009 Dec; 104(11):1561-7. PubMed ID: 19932793 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]