BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

321 related articles for article (PubMed ID: 23864338)

  • 1. A robust 3D finite element simulation of human proximal femur progressive fracture under stance load with experimental validation.
    Hambli R; Allaoui S
    Ann Biomed Eng; 2013 Dec; 41(12):2515-27. PubMed ID: 23864338
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion.
    Hambli R
    Med Biol Eng Comput; 2013 Feb; 51(1-2):219-31. PubMed ID: 23179412
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element prediction of proximal femur fracture pattern based on orthotropic behaviour law coupled to quasi-brittle damage.
    Hambli R; Bettamer A; Allaoui S
    Med Eng Phys; 2012 Mar; 34(2):202-10. PubMed ID: 21824797
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Robust QCT/FEA models of proximal femur stiffness and fracture load during a sideways fall on the hip.
    Dragomir-Daescu D; Op Den Buijs J; McEligot S; Dai Y; Entwistle RC; Salas C; Melton LJ; Bennet KE; Khosla S; Amin S
    Ann Biomed Eng; 2011 Feb; 39(2):742-55. PubMed ID: 21052839
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Integrated remodeling-to-fracture finite element model of human proximal femur behavior.
    Hambli R; Lespessailles E; Benhamou CL
    J Mech Behav Biomed Mater; 2013 Jan; 17():89-106. PubMed ID: 23122886
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Femoral fracture load and fracture pattern is accurately predicted using a gradient-enhanced quasi-brittle finite element model.
    Haider IT; Goldak J; Frei H
    Med Eng Phys; 2018 May; 55():1-8. PubMed ID: 29551293
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prediction of proximal femur strength using a CT-based nonlinear finite element method: differences in predicted fracture load and site with changing load and boundary conditions.
    Bessho M; Ohnishi I; Matsumoto T; Ohashi S; Matsuyama J; Tobita K; Kaneko M; Nakamura K
    Bone; 2009 Aug; 45(2):226-31. PubMed ID: 19398043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur.
    Koivumäki JE; Thevenot J; Pulkkinen P; Kuhn V; Link TM; Eckstein F; Jämsä T
    Bone; 2012 Apr; 50(4):824-9. PubMed ID: 22306697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element prediction with experimental validation of damage distribution in single trabeculae during three-point bending tests.
    Ridha H; Thurner PJ
    J Mech Behav Biomed Mater; 2013 Nov; 27():94-106. PubMed ID: 23890577
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.
    Miura M; Nakamura J; Matsuura Y; Wako Y; Suzuki T; Hagiwara S; Orita S; Inage K; Kawarai Y; Sugano M; Nawata K; Ohtori S
    BMC Musculoskelet Disord; 2017 Dec; 18(1):536. PubMed ID: 29246133
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load.
    Keyak JH; Falkinstein Y
    Med Eng Phys; 2003 Nov; 25(9):781-7. PubMed ID: 14519351
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prediction of strength and strain of the proximal femur by a CT-based finite element method.
    Bessho M; Ohnishi I; Matsuyama J; Matsumoto T; Imai K; Nakamura K
    J Biomech; 2007; 40(8):1745-53. PubMed ID: 17034798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.
    Haider IT; Speirs AD; Frei H
    J Biomech; 2013 Sep; 46(13):2115-21. PubMed ID: 23906770
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations.
    Yosibash Z; Trabelsi N; Milgrom C
    J Biomech; 2007; 40(16):3688-99. PubMed ID: 17706228
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Specimen-specific modeling of hip fracture pattern and repair.
    Ali AA; Cristofolini L; Schileo E; Hu H; Taddei F; Kim RH; Rullkoetter PJ; Laz PJ
    J Biomech; 2014 Jan; 47(2):536-43. PubMed ID: 24275435
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel approach of predicting fracture load in the human proximal femur using non-invasive QCT imaging technique.
    Lee T; Pereira BP; Chung YS; Oh HJ; Choi JB; Lim D; Shin JH
    Ann Biomed Eng; 2009 May; 37(5):966-75. PubMed ID: 19288197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mapping anisotropy improves QCT-based finite element estimation of hip strength in pooled stance and side-fall load configurations.
    Panyasantisuk J; Dall'Ara E; Pretterklieber M; Pahr DH; Zysset PK
    Med Eng Phys; 2018 Sep; 59():36-42. PubMed ID: 30131112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cortical bone finite element models in the estimation of experimentally measured failure loads in the proximal femur.
    Koivumäki JE; Thevenot J; Pulkkinen P; Kuhn V; Link TM; Eckstein F; Jämsä T
    Bone; 2012 Oct; 51(4):737-40. PubMed ID: 22796418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved prediction of proximal femoral fracture load using nonlinear finite element models.
    Keyak JH
    Med Eng Phys; 2001 Apr; 23(3):165-73. PubMed ID: 11410381
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fracture prediction for the proximal femur using finite element models: Part I--Linear analysis.
    Lotz JC; Cheal EJ; Hayes WC
    J Biomech Eng; 1991 Nov; 113(4):353-60. PubMed ID: 1762430
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.