BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

427 related articles for article (PubMed ID: 23869066)

  • 21. Ventilation-perfusion ratio distributions by mass spectrometry with membrane catheters.
    Mastenbrook SM; Dempsey JA; Massaro TA
    J Appl Physiol Respir Environ Exerc Physiol; 1982 Sep; 53(3):770-8. PubMed ID: 7130001
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ventilation-perfusion relationships in isolated blood-free perfused rabbit lungs.
    Walmrath D; König R; Ernst C; Brückner H; Grimminger F; Seeger W
    J Appl Physiol (1985); 1992 Jan; 72(1):374-82. PubMed ID: 1311291
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of Bronchoconstriction-induced Ventilation-Perfusion Mismatch on Uptake and Elimination of Isoflurane and Desflurane.
    Kretzschmar M; Kozian A; Baumgardner JE; Borges JB; Hedenstierna G; Larsson A; Hachenberg T; Schilling T
    Anesthesiology; 2017 Nov; 127(5):800-812. PubMed ID: 28857808
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of SO2 and pH on blood-gas partition coefficients of inert gases.
    Yamaguchi K; Mori M; Kawai A; Asano K; Takasugi T; Umeda A; Yokoyama T
    Adv Exp Med Biol; 1990; 277():215-24. PubMed ID: 1965757
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of interfacing between spontaneous breathing and mechanical cycles on the ventilation-perfusion distribution in canine lung injury.
    Putensen C; Räsänen J; López FA; Downs JB
    Anesthesiology; 1994 Oct; 81(4):921-30. PubMed ID: 7943842
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of vaporized perfluorocarbon on pulmonary blood flow and ventilation/perfusion distribution in a model of acute respiratory distress syndrome.
    Hübler M; Souders JE; Shade ED; Polissar NL; Schimmel C; Hlastala MP
    Anesthesiology; 2001 Dec; 95(6):1414-21. PubMed ID: 11748400
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Continuous distribution of ventilation-perfusion ratios following lung denervation in dogs by means of inert gas elimination method].
    Oku H
    Nihon Kyobu Geka Gakkai Zasshi; 1992 Sep; 40(9):1693-9. PubMed ID: 1328423
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intrapulmonary gas mixing and pulmonary gas exchange in artificially ventilated dogs.
    Schrikker AC; Wesenhagen H; Luijendijk SC
    Pflugers Arch; 1993 Oct; 425(1-2):16-21. PubMed ID: 8272372
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid infusion.
    Rees SE; Kjaergaard S; Andreassen S; Hedenstierna G
    J Appl Physiol (1985); 2006 Sep; 101(3):826-32. PubMed ID: 16763097
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Multiple inert gas elimination technique for determining ventilation/perfusion distributions in rat during normoxia, hypoxia and hyperoxia.
    Alfaro V; Roca-Acín J; Palacios L; Guitart R
    Clin Exp Pharmacol Physiol; 2001; 28(5-6):419-24. PubMed ID: 11380516
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ventilation-perfusion distributions in different porcine lung injury models.
    Neumann P; Hedenstierna G
    Acta Anaesthesiol Scand; 2001 Jan; 45(1):78-86. PubMed ID: 11152038
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Soluble gas exchange in the pulmonary airways of sheep.
    Schimmel C; Bernard SL; Anderson JC; Polissar NL; Lakshminarayan S; Hlastala MP
    J Appl Physiol (1985); 2004 Nov; 97(5):1702-8. PubMed ID: 15220303
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Correlation of thermodilution-derived extravascular lung water and ventilation/perfusion-compartments in a porcine model.
    Hartmann EK; Duenges B; Baumgardner JE; Markstaller K; David M
    Intensive Care Med; 2013 Jul; 39(7):1313-7. PubMed ID: 23595498
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Ventilation-perfusion distribution with volume-reduced, pressure-limited ventilation with permissive hypercapnia].
    Pfeiffer B; Hachenberg T; Feyerherd F; Wendt M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 Jun; 33(6):367-72. PubMed ID: 9689394
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Validation of cardiac echocardiography for measuring cardiac output to be applied for the multiple inert gas elimination technique.
    Rennotte MT; Vanoverschelde JL; Robert A; Dion R; Clerbaux T; Veriter C; Frans A
    Pathol Biol (Paris); 1998 Oct; 46(8):591-6. PubMed ID: 9871930
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Low VA/Q areas: arterial-alveolar N2 difference and multiple inert gas elimination technique.
    Radermacher P; Hérigault R; Teisseire B; Harf A; Lemaire F
    J Appl Physiol (1985); 1988 May; 64(5):2224-9. PubMed ID: 3391922
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Characteristics of impaired gas exchange in patients with chronic obstructive pulmonary disease].
    Yamaguchi K; Kawai A; Mori M; Asano K; Takasugi T; Umeda A; Kawashiro T
    Rinsho Byori; 1990 Apr; 38(4):420-5. PubMed ID: 2366388
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Linear programming analysis of VA/Q distributions: limits on central moments.
    Kapitan KS; Wagner PD
    J Appl Physiol (1985); 1986 May; 60(5):1772-81. PubMed ID: 3011729
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Contribution of multiple inert gas elimination technique to pulmonary medicine. 1. Principles and information content of the multiple inert gas elimination technique.
    Roca J; Wagner PD
    Thorax; 1994 Aug; 49(8):815-24. PubMed ID: 8091330
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Multiple inert gas elimination technique.
    Hlastala MP
    J Appl Physiol Respir Environ Exerc Physiol; 1984 Jan; 56(1):1-7. PubMed ID: 6319343
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 22.