183 related articles for article (PubMed ID: 23871305)
1. Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used.
Krüger A; Baroud G; Noriega D; Figiel J; Dorschel C; Ruchholtz S; Oberkircher L
Clin Biomech (Bristol, Avon); 2013 Aug; 28(7):725-30. PubMed ID: 23871305
[TBL] [Abstract][Full Text] [Related]
2. Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: a cadaveric study.
Krüger A; Oberkircher L; Figiel J; Floßdorf F; Bolzinger F; Noriega DC; Ruchholtz S
Spine J; 2015 May; 15(5):1092-8. PubMed ID: 24200410
[TBL] [Abstract][Full Text] [Related]
3. Minimum cement volume required in vertebral body augmentation--A biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture.
Rotter R; Schmitt L; Gierer P; Schmitz KP; Noriega D; Mittlmeier T; Meeder PJ; Martin H
Clin Biomech (Bristol, Avon); 2015 Aug; 30(7):720-5. PubMed ID: 25971847
[TBL] [Abstract][Full Text] [Related]
4. Height restoration and preservation in osteoporotic vertebral compression fractures: a biomechanical analysis of standard balloon kyphoplasty versus radiofrequency kyphoplasty in a cadaveric model.
Oberkircher L; Struewer J; Bliemel C; Buecking B; Eschbach DA; Ruchholtz S; Krueger A
J Spinal Disord Tech; 2014 Jul; 27(5):283-9. PubMed ID: 24077411
[TBL] [Abstract][Full Text] [Related]
5. Safety and clinical performance of kyphoplasty and SpineJack(®) procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study.
Noriega DC; Ramajo RH; Lite IS; Toribio B; Corredera R; Ardura F; Krüger A
Osteoporos Int; 2016 Jun; 27(6):2047-55. PubMed ID: 26856586
[TBL] [Abstract][Full Text] [Related]
6. [Is height restoration possible with a comparatively smaller amount of cement in radiofrequency kyphoplasty using a monopedicle approach?].
Röllinghoff M; Hagel A; Siewe J; Gutteck N; Delank KS; Steinmetz A; Zarghooni K
Z Orthop Unfall; 2013 Apr; 151(2):156-62. PubMed ID: 23619648
[TBL] [Abstract][Full Text] [Related]
7. Height restoration and sustainability using bilateral vertebral augmentation systems for vertebral compression fractures: a cadaveric study.
Holyoak DT; Andreshak TG; Hopkins TJ; Brook AL; Frohbergh ME; Ong KL
Spine J; 2022 Dec; 22(12):2072-2081. PubMed ID: 35753638
[TBL] [Abstract][Full Text] [Related]
8. Clinical Outcomes and Safety Comparison of Vertebroplasty, Balloon Kyphoplasty, and Vertebral Implant for Treatment of Vertebral Compression Fractures.
Li T; Pang S; England R; Gong A; Botros D; Manupipatpong S; Hui FK; Khan M
AJNR Am J Neuroradiol; 2023 Nov; 44(11):1345-1351. PubMed ID: 37918938
[TBL] [Abstract][Full Text] [Related]
9. Comparison of radiological and clinical results of balloon kyphoplasty according to anterior height loss in the osteoporotic vertebral fracture.
Lee JH; Lee DO; Lee JH; Lee HS
Spine J; 2014 Oct; 14(10):2281-9. PubMed ID: 24462536
[TBL] [Abstract][Full Text] [Related]
10. Long-term safety and clinical performance of kyphoplasty and SpineJack® procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study.
Noriega DC; Rodrίguez-Monsalve F; Ramajo R; Sánchez-Lite I; Toribio B; Ardura F
Osteoporos Int; 2019 Mar; 30(3):637-645. PubMed ID: 30488273
[TBL] [Abstract][Full Text] [Related]
11. Treatment of vertebral compression fractures with the cranio-caudal expandable implant SpineJack®: Technical note and outcomes in 77 consecutive patients.
Renaud C
Orthop Traumatol Surg Res; 2015 Nov; 101(7):857-9. PubMed ID: 26521157
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty.
Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L
Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837
[TBL] [Abstract][Full Text] [Related]
13. A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study).
Noriega D; Marcia S; Theumann N; Blondel B; Simon A; Hassel F; Maestretti G; Petit A; Weidle PA; Mandly AG; Kaya JM; Touta A; Fuentes S; Pflugmacher R
Spine J; 2019 Nov; 19(11):1782-1795. PubMed ID: 31325625
[TBL] [Abstract][Full Text] [Related]
14. [Comparison of clinical and radiological data in the treatment of patients with osteoporotic vertebral compression fractures using radiofrequency kyphoplasty or balloon kyphoplasty].
Pflugmacher R; Bornemann R; Koch EM; Randau TM; Müller-Broich J; Lehmann U; Weber O; Wirtz DC; Kabir K
Z Orthop Unfall; 2012 Feb; 150(1):56-61. PubMed ID: 21993914
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical evaluation of kyphoplasty with calcium sulfate cement in a cadaveric osteoporotic vertebral compression fracture model.
Perry A; Mahar A; Massie J; Arrieta N; Garfin S; Kim C
Spine J; 2005; 5(5):489-93. PubMed ID: 16153574
[TBL] [Abstract][Full Text] [Related]
16. Uniextrapedicular kyphoplasty for the treatment of thoracic osteoporotic vertebral fractures.
Ge Z; Ma R; Chen Z; Zhang H; Ding H; Liang S; Suo Z
Orthopedics; 2013 Aug; 36(8):e1020-4. PubMed ID: 23937747
[TBL] [Abstract][Full Text] [Related]
17. [Risk factors of non-surgical vertebral fracture after percutaneous kyphoplasty of single segment thoracolumbar fracture].
Wu J; Guan YH; Fan SL
Zhongguo Gu Shang; 2017 Sep; 30(9):833-837. PubMed ID: 29455485
[TBL] [Abstract][Full Text] [Related]
18. Kyphoplasty versus vertebroplasty: restoration of vertebral body height and correction of kyphotic deformity with special attention to the shape of the fractured vertebrae.
Kim KH; Kuh SU; Chin DK; Jin BH; Kim KS; Yoon YS; Cho YE
J Spinal Disord Tech; 2012 Aug; 25(6):338-44. PubMed ID: 21705918
[TBL] [Abstract][Full Text] [Related]
19. Clinical evaluation of a new kyphoplasty technique with directed cement flow.
Zarate B; Gutierrez J; Wakhloo AK; Gounis MJ; Reyes-Sánchez A
J Spinal Disord Tech; 2012 May; 25(3):E61-6. PubMed ID: 22343281
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.
Upasani VV; Robertson C; Lee D; Tomlinson T; Mahar AT
Spine (Phila Pa 1976); 2010 Sep; 35(19):1783-8. PubMed ID: 20098352
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]