477 related articles for article (PubMed ID: 23872010)
1. Rational design of a thrombin electrochemical aptasensor by conjugating two DNA aptamers with G-quadruplex halves.
Yan Z; Han Z; Huang H; Shen H; Lu X
Anal Biochem; 2013 Nov; 442(2):237-40. PubMed ID: 23872010
[TBL] [Abstract][Full Text] [Related]
2. Strategy to fabricate an electrochemical aptasensor: application to the assay of adenosine deaminase activity.
Zhang K; Zhu X; Wang J; Xu L; Li G
Anal Chem; 2010 Apr; 82(8):3207-11. PubMed ID: 20345118
[TBL] [Abstract][Full Text] [Related]
3. Electrochemical aptasensor based on the dual-amplification of G-quadruplex horseradish peroxidase-mimicking DNAzyme and blocking reagent-horseradish peroxidase.
Yuan Y; Gou X; Yuan R; Chai Y; Zhuo Y; Mao L; Gan X
Biosens Bioelectron; 2011 Jun; 26(10):4236-40. PubMed ID: 21536422
[TBL] [Abstract][Full Text] [Related]
4. A pseudo triple-enzyme cascade amplified aptasensor for thrombin detection based on hemin/G-quadruplex as signal label.
Yi H; Xu W; Yuan Y; Bai L; Wu Y; Chai Y; Yuan R
Biosens Bioelectron; 2014 Apr; 54():415-20. PubMed ID: 24296062
[TBL] [Abstract][Full Text] [Related]
5. An amplified electrochemical aptasensor for thrombin detection based on pseudobienzymic Fe3O4-Au nanocomposites and electroactive hemin/G-quadruplex as signal enhancers.
Jing P; Xu W; Yi H; Wu Y; Bai L; Yuan R
Analyst; 2014 Apr; 139(7):1756-61. PubMed ID: 24519466
[TBL] [Abstract][Full Text] [Related]
6. A novel electrochemical aptasensor for thrombin detection based on the hybridization chain reaction with hemin/G-quadruplex DNAzyme-signal amplification.
Zhang J; Chai Y; Yuan R; Yuan Y; Bai L; Xie S; Jiang L
Analyst; 2013 Aug; 138(16):4558-64. PubMed ID: 23741737
[TBL] [Abstract][Full Text] [Related]
7. A pseudo triple-enzyme electrochemical aptasensor based on the amplification of Pt-Pd nanowires and hemin/G-quadruplex.
Zheng Y; Chai Y; Yuan Y; Yuan R
Anal Chim Acta; 2014 Jun; 834():45-50. PubMed ID: 24928244
[TBL] [Abstract][Full Text] [Related]
8. Porous platinum nanotubes labeled with hemin/G-quadruplex based electrochemical aptasensor for sensitive thrombin analysis via the cascade signal amplification.
Sun A; Qi Q; Wang X; Bie P
Biosens Bioelectron; 2014 Jul; 57():16-21. PubMed ID: 24534575
[TBL] [Abstract][Full Text] [Related]
9. An ultrasensitive electrochemical aptasensor for thrombin based on the triplex-amplification of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme and horseradish peroxidase decorated FeTe nanorods.
Jiang L; Yuan R; Chai Y; Yuan Y; Bai L; Wang Y
Analyst; 2013 Mar; 138(5):1497-503. PubMed ID: 23340527
[TBL] [Abstract][Full Text] [Related]
10. Amplified thrombin aptasensor based on alkaline phosphatase and hemin/G-quadruplex-catalyzed oxidation of 1-naphthol.
Yang ZH; Zhuo Y; Yuan R; Chai YQ
ACS Appl Mater Interfaces; 2015 May; 7(19):10308-15. PubMed ID: 25907268
[TBL] [Abstract][Full Text] [Related]
11. Highly sensitive electrochemical thrombin aptasensor based on peptide-enhanced electrocatalysis of hemin/G-quadruplex and nanocomposite as nanocarrier.
Wu Y; Zou L; Lei S; Yu Q; Ye B
Biosens Bioelectron; 2017 Nov; 97():317-324. PubMed ID: 28622642
[TBL] [Abstract][Full Text] [Related]
12. A dual-amplification aptasensor for highly sensitive detection of thrombin based on the functionalized graphene-Pd nanoparticles composites and the hemin/G-quadruplex.
Xie S; Chai Y; Yuan R; Bai L; Yuan Y; Wang Y
Anal Chim Acta; 2012 Nov; 755():46-53. PubMed ID: 23146393
[TBL] [Abstract][Full Text] [Related]
13. Hemin/G-quadruplex-catalyzed aerobic oxidation of thiols to disulfides: application of the process for the development of sensors and aptasensors and for probing acetylcholine esterase activity.
Golub E; Freeman R; Willner I
Anal Chem; 2013 Dec; 85(24):12126-33. PubMed ID: 24299064
[TBL] [Abstract][Full Text] [Related]
14. Aptamer-linked biosensor for thrombin based on AuNPs/thionine-graphene nanocomposite.
Zhang Z; Luo L; Zhu L; Ding Y; Deng D; Wang Z
Analyst; 2013 Sep; 138(18):5365-70. PubMed ID: 23877321
[TBL] [Abstract][Full Text] [Related]
15. Electrochemical aptasensor for thrombin using co-catalysis of hemin/G-quadruplex DNAzyme and octahedral Cu
Chen S; Liu P; Su K; Li X; Qin Z; Xu W; Chen J; Li C; Qiu J
Biosens Bioelectron; 2018 Jan; 99():338-345. PubMed ID: 28800505
[TBL] [Abstract][Full Text] [Related]
16. Multifunctional label-free electrochemical biosensor based on an integrated aptamer.
Du Y; Li B; Wei H; Wang Y; Wang E
Anal Chem; 2008 Jul; 80(13):5110-7. PubMed ID: 18522435
[TBL] [Abstract][Full Text] [Related]
17. A portable microchip for ultrasensitive and high-throughput assay of thrombin by rolling circle amplification and hemin/G-quadruplex system.
Lin X; Chen Q; Liu W; Li H; Lin JM
Biosens Bioelectron; 2014 Jun; 56():71-6. PubMed ID: 24469539
[TBL] [Abstract][Full Text] [Related]
18. A novel electrochemical aptasensor for highly sensitive detection of thrombin based on the autonomous assembly of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme nanowires.
Xie S; Chai Y; Yuan Y; Bai L; Yuan R
Anal Chim Acta; 2014 Jun; 832():51-7. PubMed ID: 24890694
[TBL] [Abstract][Full Text] [Related]
19. A label-free electrochemical aptasensor for the analysis of the potassium ion.
Ji X; Li J; Yang C
J Immunoassay Immunochem; 2015; 36(2):162-9. PubMed ID: 24785341
[TBL] [Abstract][Full Text] [Related]
20. An aptasensing platform for simultaneous detection of multiple analytes based on the amplification of exonuclease-catalyzed target recycling and DNA concatemers.
Jiang L; Peng J; Yuan R; Chai Y; Yuan Y; Bai L; Wang Y
Analyst; 2013 Sep; 138(17):4818-22. PubMed ID: 23817314
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]