BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 23876751)

  • 41. Quality of hematology and clinical chemistry results in laboratory and zoo nonhuman primates: Effects of the preanalytical phase. A review.
    Granat FA; Trumel C; Braun JD; Bourgès-Abella NH
    J Med Primatol; 2023 Dec; 52(6):414-427. PubMed ID: 37612808
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Commentary: biological standardisation in haemostasis and haematology.
    Longstaff C
    Biologicals; 2010 Jul; 38(4):421-2. PubMed ID: 20347332
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.
    HarsimranKaur VN; Selhi PK; Sood N; Singh A
    Iran J Pathol; 2016; 11(2):151-4. PubMed ID: 27499777
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Preanalytical error occurrence rate in clinical chemistry laboratory of a public hospital in India.
    Singla P; Parkash AA; Bhattacharjee J
    Clin Lab; 2011; 57(9-10):749-52. PubMed ID: 22029191
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Monitoring and reporting of preanalytical errors in laboratory medicine: the UK situation.
    Cornes MP; Atherton J; Pourmahram G; Borthwick H; Kyle B; West J; Costelloe SJ
    Ann Clin Biochem; 2016 Mar; 53(Pt 2):279-84. PubMed ID: 26195485
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience.
    Fernandez P; Llopis MA; Perich C; Alsina MJ; Alvarez V; Biosca C; Busquets G; Domenech MV; Gómez R; Llovet I; Minchinela J; Pastor R; Ruiz R; Tarrés E; Ibarz M; Simón M; Montesinos M
    Clin Chem Lab Med; 2014 Nov; 52(11):1557-68. PubMed ID: 24897397
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Perspectives and advances in in-clinic laboratory diagnostic capabilities: hematology and clinical chemistry.
    Weiser MG; Vap LM; Thrall MA
    Vet Clin North Am Small Anim Pract; 2007 Mar; 37(2):221-36, v. PubMed ID: 17336672
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Hematological Assessment in Pet Guinea Pigs (Cavia porcellus): Blood Sample Collection and Blood Cell Identification.
    Zimmerman K; Moore DM; Smith SA
    Clin Lab Med; 2015 Sep; 35(3):641-8. PubMed ID: 26297410
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The knowledge and understanding of preanalytical phase among biomedicine students at the University of Zagreb.
    Dukic L; Jokic A; Kules J; Pasalic D
    Biochem Med (Zagreb); 2016; 26(1):90-7. PubMed ID: 26981023
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Quality standards for sample collection in coagulation testing.
    Lippi G; Salvagno GL; Montagnana M; Lima-Oliveira G; Guidi GC; Favaloro EJ
    Semin Thromb Hemost; 2012 Sep; 38(6):565-75. PubMed ID: 22669757
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Post-analytical Issues in Hemostasis and Thrombosis Testing: An Update.
    Favaloro EJ; Gosselin RC; Pasalic L; Lippi G
    Methods Mol Biol; 2023; 2663():787-811. PubMed ID: 37204753
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Evacuated blood-collection tubes for haematological tests - a quality evaluation prior to their intended use for specimen collection.
    Gros N
    Clin Chem Lab Med; 2013 May; 51(5):1043-51. PubMed ID: 23079516
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Hematology analyzers: special considerations for pediatric patients.
    Wong EC
    Clin Lab Med; 2015 Mar; 35(1):165-81. PubMed ID: 25676378
    [TBL] [Abstract][Full Text] [Related]  

  • 54. New erythrocyte and reticulocyte parameters on CELL-DYN Sapphire: analytical and preanalytical aspects.
    Ermens AA; Hoffmann JJ; Krockenberger M; Van Wijk EM
    Int J Lab Hematol; 2012 Jun; 34(3):274-82. PubMed ID: 22151199
    [TBL] [Abstract][Full Text] [Related]  

  • 55. An Overview of Complete Blood Count Sample Rejection Rates in a Clinical Hematology Laboratory Due to Various Preanalytical Errors.
    Noor T; Imran A; Raza H; Umer S; Malik NA; Chughtai AS
    Cureus; 2023 Jan; 15(1):e34444. PubMed ID: 36874705
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Patient safety and quality in laboratory and hemostasis testing: a renewed loop?
    Plebani M; Favaloro EJ; Lippi G
    Semin Thromb Hemost; 2012 Sep; 38(6):553-8. PubMed ID: 22660919
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Quality assessment for preanalytical phase in clinical laboratory: a multicentric study].
    Salinas M; López-Garrigós M; Yago M; Ortuño M; Carratala A; Aguado C; Díaz J; Rodriguez-Borja E; Chinchilla V; Esteban A; Laíz B; Lorente MÁ; Uris J
    Rev Calid Asist; 2011; 26(4):264-8. PubMed ID: 21621440
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Preanalytical variations of proteic biomarkers].
    Lambert D; Berrahmoune H; Herbeth B; Siest G; Visvikis-Siest S
    Med Sci (Paris); 2007 Mar; 23 Spec No 1():9-12. PubMed ID: 17669346
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Preanalytical phase and accreditation: acceptance criteria for samples of multisite laboratory].
    Dialma P; Piaulenne S; Baty S; Zeitoun T
    Ann Biol Clin (Paris); 2013; 71(1):121-8. PubMed ID: 23396436
    [TBL] [Abstract][Full Text] [Related]  

  • 60. [Guidance for cytological automation in hematology].
    Gruson A; Chatron P
    Ann Biol Clin (Paris); 2019 Apr; 77(2):128-129. PubMed ID: 30998193
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.