These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 23880279)

  • 1. Reciprocating root canal technique induces greater debris accumulation than a continuous rotary technique as assessed by 3-dimensional micro-computed tomography.
    Robinson JP; Lumley PJ; Cooper PR; Grover LM; Walmsley AD
    J Endod; 2013 Aug; 39(8):1067-70. PubMed ID: 23880279
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduction of hard-tissue debris accumulation during rotary root canal instrumentation by etidronic acid in a sodium hypochlorite irrigant.
    Paqué F; Rechenberg DK; Zehnder M
    J Endod; 2012 May; 38(5):692-5. PubMed ID: 22515905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing accumulated hard-tissue debris using micro-computed tomography and free software for image processing and analysis.
    De-Deus G; Marins J; Neves Ade A; Reis C; Fidel S; Versiani MA; Alves H; Lopes RT; Paciornik S
    J Endod; 2014 Feb; 40(2):271-6. PubMed ID: 24461417
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hard-tissue debris accumulation created by conventional rotary versus self-adjusting file instrumentation in mesial root canal systems of mandibular molars.
    Paqué F; Al-Jadaa A; Kfir A
    Int Endod J; 2012 May; 45(5):413-8. PubMed ID: 22188277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Micro-CT analyses of apical enlargement and molar root canal complexity.
    Markvart M; Darvann TA; Larsen P; Dalstra M; Kreiborg S; Bjørndal L
    Int Endod J; 2012 Mar; 45(3):273-81. PubMed ID: 22044111
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlative bacteriologic and micro-computed tomographic analysis of mandibular molar mesial canals prepared by self-adjusting file, reciproc, and twisted file systems.
    Siqueira JF; Alves FR; Versiani MA; Rôças IN; Almeida BM; Neves MA; Sousa-Neto MD
    J Endod; 2013 Aug; 39(8):1044-50. PubMed ID: 23880274
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Micro-computed tomography study of oval-shaped canals prepared with the self-adjusting file, Reciproc, WaveOne, and ProTaper universal systems.
    Versiani MA; Leoni GB; Steier L; De-Deus G; Tassani S; Pécora JD; de Sousa-Neto MD
    J Endod; 2013 Aug; 39(8):1060-6. PubMed ID: 23880278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of single-file endodontics on apical transportation in curved root canals: an ex vivo micro-computed tomographic study.
    Junaid A; Freire LG; da Silveira Bueno CE; Mello I; Cunha RS
    J Endod; 2014 May; 40(5):717-20. PubMed ID: 24767570
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Micro-computed tomographic evaluation of the effect of the final apical size prepared by rotary nickel-titanium files on the removal efficacy of hard-tissue debris.
    Xu K; Wang J; Wang K; Gen N; Li J
    J Int Med Res; 2018 Jun; 46(6):2219-2229. PubMed ID: 29584511
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.
    Peru M; Peru C; Mannocci F; Sherriff M; Buchanan LS; Pitt Ford TR
    Eur J Dent Educ; 2006 Feb; 10(1):52-9. PubMed ID: 16436085
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-adjusting files in retreatment: a high-resolution micro-computed tomography study.
    Solomonov M; Paqué F; Kaya S; Adigüzel O; Kfir A; Yiğit-Özer S
    J Endod; 2012 Sep; 38(9):1283-7. PubMed ID: 22892752
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Micro-computed tomography evaluation of the preparation of long oval root canals in mandibular molars with the self-adjusting file.
    Paqué F; Peters OA
    J Endod; 2011 Apr; 37(4):517-21. PubMed ID: 21419301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.
    Paqué F; Zehnder M; De-Deus G
    J Endod; 2011 Oct; 37(10):1394-7. PubMed ID: 21924189
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accumulated hard tissue debris produced during reciprocating and rotary nickel-titanium canal preparation.
    De-Deus G; Marins J; Silva EJ; Souza E; Belladonna FG; Reis C; Machado AS; Lopes RT; Versiani MA; Paciornik S; Neves AA
    J Endod; 2015 May; 41(5):676-81. PubMed ID: 25670245
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A high-resolution computed tomographic study of changes in root canal isthmus area by instrumentation and root filling.
    Endal U; Shen Y; Knut A; Gao Y; Haapasalo M
    J Endod; 2011 Feb; 37(2):223-7. PubMed ID: 21238806
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Debris remaining in the apical third of root canals after chemomechanical preparation by using sodium hypochlorite and glyde: an in vivo study.
    Cruz A; Vera J; Gascón G; Palafox-Sánchez CA; Amezcua O; Mercado G
    J Endod; 2014 Sep; 40(9):1419-23. PubMed ID: 25146024
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes in centring and shaping ability using three nickel–titanium instrumentation techniques analysed by micro-computed tomography (μCT).
    Stern S; Patel S; Foschi F; Sherriff M; Mannocci F
    Int Endod J; 2012 Jun; 45(6):514-23. PubMed ID: 22625863
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elimination of intracanal tissue and debris through a novel laser-activated system assessed using high-resolution micro-computed tomography: a pilot study.
    Lloyd A; Uhles JP; Clement DJ; Garcia-Godoy F
    J Endod; 2014 Apr; 40(4):584-7. PubMed ID: 24666917
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals.
    Pasqualini D; Bianchi CC; Paolino DS; Mancini L; Cemenasco A; Cantatore G; Castellucci A; Berutti E
    J Endod; 2012 Mar; 38(3):389-93. PubMed ID: 22341081
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An analytical Micro CT methodology for quantifying inorganic dentine debris following internal tooth preparation.
    Robinson JP; Lumley PJ; Claridge E; Cooper PR; Grover LM; Williams RL; Walmsley AD
    J Dent; 2012 Nov; 40(11):999-1005. PubMed ID: 22922224
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.