155 related articles for article (PubMed ID: 23886417)
1. On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter.
Juang T; Das S; Adamovics J; Benning R; Oldham M
Int J Radiat Oncol Biol Phys; 2013 Oct; 87(2):414-21. PubMed ID: 23886417
[TBL] [Abstract][Full Text] [Related]
2. WE-E-BRB-04: Quantitative Dose Tracking Enabled Through a Novel Deformable 3D Dosimeter.
Juang T; Newton J; Das S; Adamovics J; Oldham M
Med Phys; 2012 Jun; 39(6Part27):3956. PubMed ID: 28519995
[TBL] [Abstract][Full Text] [Related]
3. Utility and validation of biomechanical deformable image registration in low-contrast images.
Velec M; Juang T; Moseley JL; Oldham M; Brock KK
Pract Radiat Oncol; 2015; 5(4):e401-8. PubMed ID: 25823381
[TBL] [Abstract][Full Text] [Related]
4. Development of a 3D remote dosimetry protocol compatible with MRgIMRT.
Mein S; Rankine L; Adamovics J; Li H; Oldham M
Med Phys; 2017 Nov; 44(11):6018-6028. PubMed ID: 28877344
[TBL] [Abstract][Full Text] [Related]
5. Preliminary investigation and application of a novel deformable PRESAGE
Juang T; Newton J; Das S; Adamovics J; Oldham M
J Phys Conf Ser; 2013; 444():12080. PubMed ID: 24454522
[TBL] [Abstract][Full Text] [Related]
6. Is it sensible to "deform" dose? 3D experimental validation of dose-warping.
Yeo UJ; Taylor ML; Supple JR; Smith RL; Dunn L; Kron T; Franich RD
Med Phys; 2012 Aug; 39(8):5065-72. PubMed ID: 22894432
[TBL] [Abstract][Full Text] [Related]
7. Deformable scintillation dosimeter: II. Real-time simultaneous measurements of dose and tracking of deformation vector fields.
Cloutier E; Beaulieu L; Archambault L
Phys Med Biol; 2021 Aug; 66(17):. PubMed ID: 34380121
[TBL] [Abstract][Full Text] [Related]
8. Characterization of a new radiochromic three-dimensional dosimeter.
Guo PY; Adamovics JA; Oldham M
Med Phys; 2006 May; 33(5):1338-45. PubMed ID: 16752569
[TBL] [Abstract][Full Text] [Related]
9. Performance of 12 DIR algorithms in low-contrast regions for mass and density conserving deformation.
Yeo UJ; Supple JR; Taylor ML; Smith R; Kron T; Franich RD
Med Phys; 2013 Oct; 40(10):101701. PubMed ID: 24089891
[TBL] [Abstract][Full Text] [Related]
10. A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.
Sakhalkar HS; Adamovics J; Ibbott G; Oldham M
Med Phys; 2009 Jan; 36(1):71-82. PubMed ID: 19235375
[TBL] [Abstract][Full Text] [Related]
11. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
[TBL] [Abstract][Full Text] [Related]
12. A practical three-dimensional dosimetry system for radiation therapy.
Guo P; Adamovics J; Oldham M
Med Phys; 2006 Oct; 33(10):3962-72. PubMed ID: 17089858
[TBL] [Abstract][Full Text] [Related]
13. On the feasibility of comprehensive high-resolution 3D remote dosimetry.
Juang T; Grant R; Adamovics J; Ibbott G; Oldham M
Med Phys; 2014 Jul; 41(7):071706. PubMed ID: 24989375
[TBL] [Abstract][Full Text] [Related]
14. A novel methodology for 3D deformable dosimetry.
Yeo UJ; Taylor ML; Dunn L; Kron T; Smith RL; Franich RD
Med Phys; 2012 Apr; 39(4):2203-13. PubMed ID: 22482642
[TBL] [Abstract][Full Text] [Related]
15. Customising PRESAGE
Juang T; Newton J; Niebanck M; Benning R; Adamovics J; Oldham M
J Phys Conf Ser; 2013; 444():012029. PubMed ID: 24567739
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the accuracy of deformable image registration on MRI with a physical phantom.
Wu RY; Liu AY; Yang J; Williamson TD; Wisdom PG; Bronk L; Gao S; Grosshan DR; Fuller DC; Gunn GB; Ronald Zhu X; Frank SJ
J Appl Clin Med Phys; 2020 Jan; 21(1):166-173. PubMed ID: 31808307
[TBL] [Abstract][Full Text] [Related]
17. Temperature dependence and temporal stability of stacked radiochromic sheets for three-dimensional dose verification.
Liu K; Wang YF; Dona Lemus OM; Adamovics J; Wuu CS
Med Phys; 2020 Nov; 47(11):5906-5918. PubMed ID: 32996168
[TBL] [Abstract][Full Text] [Related]
18. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System.
Rankine LJ; Mein S; Cai B; Curcuru A; Juang T; Miles D; Mutic S; Wang Y; Oldham M; Li HH
Int J Radiat Oncol Biol Phys; 2017 Apr; 97(5):1095-1104. PubMed ID: 28332995
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of an x-ray CT polymer gel dosimetry system in the measurement of deformed dose.
Maynard E; Heath E; Hilts M; Jirasek A
Biomed Phys Eng Express; 2020 Apr; 6(3):035031. PubMed ID: 33438676
[TBL] [Abstract][Full Text] [Related]
20. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.
Landry G; Nijhuis R; Dedes G; Handrack J; Thieke C; Janssens G; Orban de Xivry J; Reiner M; Kamp F; Wilkens JJ; Paganelli C; Riboldi M; Baroni G; Ganswindt U; Belka C; Parodi K
Med Phys; 2015 Mar; 42(3):1354-66. PubMed ID: 25735290
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]