These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 23891167)

  • 1. The use of navigation to achieve soft tissue balance in total knee arthroplasty - a randomised clinical study.
    Joseph J; Simpson PM; Whitehouse SL; English HW; Donnelly WJ
    Knee; 2013 Dec; 20(6):401-6. PubMed ID: 23891167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computer-navigated versus conventional total knee arthroplasty a prospective randomized trial.
    Kim YH; Park JW; Kim JS
    J Bone Joint Surg Am; 2012 Nov; 94(22):2017-24. PubMed ID: 23052635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prediction of post-operative range of motion using intra-operative soft tissue balance in total knee arthroplasty with navigation.
    Hasegawa M; Takagita H; Sudo A
    Comput Aided Surg; 2015; 20(1):47-51. PubMed ID: 26291504
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flexion-extension gaps balanced using navigation assistance in TKA.
    Song EK; Seon JK; Park SJ
    Orthopedics; 2009 Oct; 32(10 Suppl):26-30. PubMed ID: 19835304
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Long-Term Results of Computer-Navigated Total Knee Arthroplasties Performed by Low-Volume and Less Experienced Surgeon].
    Lacko M; Schreierová D; Čellár R; Vaško G
    Acta Chir Orthop Traumatol Cech; 2018; 85(3):219-225. PubMed ID: 30257783
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computer-assisted total knee arthroplasty: comparative results in a preliminary series of 72 cases.
    Zorman D; Etuin P; Jennart H; Scipioni D; Devos S
    Acta Orthop Belg; 2005 Dec; 71(6):696-702. PubMed ID: 16459860
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique.
    Pang HN; Yeo SJ; Chong HC; Chin PL; Ong J; Lo NN
    Knee Surg Sports Traumatol Arthrosc; 2011 Sep; 19(9):1496-503. PubMed ID: 21448662
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables.
    Fickert S; Jawhar A; Sunil P; Scharf HP
    Arch Orthop Trauma Surg; 2012 Apr; 132(4):565-74. PubMed ID: 22072193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The reliability of navigation-guided gap technique in total knee arthroplasty.
    Han SB; Nha KW; Yoon JR; Lee DH; Chae IJ
    Orthopedics; 2008 Oct; 31(10 Suppl 1):. PubMed ID: 19298036
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of navigation to obtain rectangular flexion and extension gaps during primary total knee arthroplasty and midterm clinical results.
    Seon JK; Song EK; Park SJ; Lee DS
    J Arthroplasty; 2011 Jun; 26(4):582-90. PubMed ID: 20580194
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computer-assisted navigation increases precision of component placement in total knee arthroplasty.
    Haaker RG; Stockheim M; Kamp M; Proff G; Breitenfelder J; Ottersbach A
    Clin Orthop Relat Res; 2005 Apr; (433):152-9. PubMed ID: 15805951
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Are joint line changes after primary navigated total knee arthroplasty predictable?
    Jawhar A; Hutter K; Scharf HP
    J Orthop Sci; 2015 Jan; 20(1):93-100. PubMed ID: 25217136
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcomes of 447 SCORE® highly congruent mobile-bearing total knee arthroplasties after 5-10 years follow-up.
    Châtain F; Gaillard TH; Denjean S; Tayot O
    Orthop Traumatol Surg Res; 2013 Oct; 99(6):681-6. PubMed ID: 23988419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age.
    de Steiger RN; Liu YL; Graves SE
    J Bone Joint Surg Am; 2015 Apr; 97(8):635-42. PubMed ID: 25878307
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system.
    Matsumoto T; Muratsu H; Tsumura N; Mizuno K; Kuroda R; Yoshiya S; Kurosaka M
    J Biomech Eng; 2006 Dec; 128(6):867-71. PubMed ID: 17154688
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems.
    Harvie P; Sloan K; Beaver RJ
    J Arthroplasty; 2011 Dec; 26(8):1285-90. PubMed ID: 21316913
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of balanced gap total knee arthroplasty on intraoperative laxities and femoral component rotation.
    Lee DS; Song EK; Seon JK; Park SJ
    J Arthroplasty; 2011 Aug; 26(5):699-704. PubMed ID: 20647162
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study.
    Dutton AQ; Yeo SJ; Yang KY; Lo NN; Chia KU; Chong HC
    J Bone Joint Surg Am; 2008 Jan; 90(1):2-9. PubMed ID: 18171951
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flexion and extension gap balancing in revision total knee arthroplasty.
    Mihalko WM; Krackow KA
    Clin Orthop Relat Res; 2006 May; 446():121-6. PubMed ID: 16672881
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using navigation intraoperative measurements narrows range of outcomes in TKA.
    Picard F; Deakin AH; Clarke JV; Dillon JM; Gregori A
    Clin Orthop Relat Res; 2007 Oct; 463():50-7. PubMed ID: 17632421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.