These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 23891958)

  • 1. Palpitations in a patient with a dual-chamber pacemaker: what is the mechanism?
    Santangeli P; Tsiperfal A; Wang PJ; Al-Ahmad A
    Heart Rhythm; 2013 Dec; 10(12):1824-5. PubMed ID: 23891958
    [No Abstract]   [Full Text] [Related]  

  • 2. Premature ventricular contractions causing pacemaker-mediated tachycardia: a failure of postventricular atrial refractory period after premature ventricular contraction extension?
    Witteles R; Engel G; Wang PJ; Al-Ahmad A
    Heart Rhythm; 2005 Dec; 2(12):1389-90. PubMed ID: 16360099
    [No Abstract]   [Full Text] [Related]  

  • 3. Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm.
    Barold SS; Van Heuverswyn F; Stroobandt RX
    J Electrocardiol; 2013; 46(2):136-9. PubMed ID: 23399053
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ventricular arrhythmias after leadless pacemaker implantation, a case report and systematic review of the literature.
    Aparisi Á; Sandín-Fuentes M; García-Granja PE; García-Morán E; Rubio J
    J Cardiovasc Electrophysiol; 2020 Jan; 31(1):227-228. PubMed ID: 31808227
    [No Abstract]   [Full Text] [Related]  

  • 5. Inhibition of ventricular stimulation in patients with dual chamber pacemakers and prolonged AV conduction.
    Bode F; Wiegand U; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 1999 Oct; 22(10):1425-31. PubMed ID: 10588143
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Varying Morphology of QRS Complexes: A Possible Explanation.
    Laeeq R; Pollet M; Faza N; Birnbaum Y
    Tex Heart Inst J; 2017 Dec; 44(6):429-430. PubMed ID: 29276447
    [No Abstract]   [Full Text] [Related]  

  • 7. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia.
    Sharma PS; Kaszala K; Tan AY; Koneru JN; Shepard R; Ellenbogen KA; Huizar JF
    Heart Rhythm; 2016 Aug; 13(8):1739-47. PubMed ID: 27050909
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Undersensing of P waves in the presence of an adequate P wave due to automatic postventricular atrial refractory period extension.
    Wilson JH; Lattner S
    Pacing Clin Electrophysiol; 1989 Nov; 12(11):1729-32. PubMed ID: 2478971
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of far-field R wave sensing for the avoidance of inappropriate mode switch in dual chamber pacemakers: results of the FFS-test study.
    Kolb C; Wille B; Maurer D; Schuchert A; Weber R; Schibgilla V; Klein N; Hümmer A; Schmitt C; Zrenner B;
    J Cardiovasc Electrophysiol; 2006 Sep; 17(9):992-7. PubMed ID: 16948743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differentiating pacemaker-mediated tachycardia from tachycardia due to atrial tracking: utility of V-A-A-V versus V-A-V response after postventricular atrial refractory period extension.
    Ip JE; Markowitz SM; Liu CF; Cheung JW; Thomas G; Lerman BB
    Heart Rhythm; 2011 Aug; 8(8):1185-91. PubMed ID: 21376834
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pacemaker-mediated tachycardia initiated by coincident P-wave undersensing and ventricular blanking period.
    Lamas GA; Antman EM
    Pacing Clin Electrophysiol; 1985 May; 8(3 Pt 1):436-9. PubMed ID: 2582394
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Undersensing of ventricular tachycardia in a pacemaker patient: What is the mechanism?
    Monkhouse C; Whittaker-Axon S; Chow AW
    Pacing Clin Electrophysiol; 2018 May; 41(5):553-556. PubMed ID: 29476536
    [No Abstract]   [Full Text] [Related]  

  • 13. An unusual termination of a wide complex tachycardia.
    Cassagneau R; Sunni N; Skanes A; Klein GJ
    J Cardiovasc Electrophysiol; 2014 May; 25(5):549-552. PubMed ID: 24350631
    [No Abstract]   [Full Text] [Related]  

  • 14. Dual chamber pacemakers: upper rate behavior.
    Furman S
    Pacing Clin Electrophysiol; 1985 Mar; 8(2):197-214. PubMed ID: 2580281
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review.
    Barold SS; Levine PA
    J Interv Card Electrophysiol; 2001 Mar; 5(1):45-58. PubMed ID: 11248774
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wide complex tachycardia and dual-chamber pacing.
    Kantharia BK
    Heart Rhythm; 2005 Sep; 2(9):1013-4. PubMed ID: 16171762
    [No Abstract]   [Full Text] [Related]  

  • 17. Atrial lead malfunction presenting as new onset pacemaker-mediated tachycardia.
    Barold SS; Stroobandt RX
    Europace; 2012 Jul; 14(7):1060-1. PubMed ID: 22286204
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ventricular tachycardia terminated by an ICD: is there more than what meets the eye?
    Lau EW; Green MS; Birnie DH; Lemery R; Tang AS
    Pacing Clin Electrophysiol; 2004 Dec; 27(12):1656-8. PubMed ID: 15613130
    [No Abstract]   [Full Text] [Related]  

  • 19. Idiopathic ventricular tachycardia originating in the great cardiac vein.
    Meininger GR; Berger RD
    Heart Rhythm; 2006 Apr; 3(4):464-6. PubMed ID: 16567296
    [No Abstract]   [Full Text] [Related]  

  • 20. A new algorithm for a high level of protection against pacemaker-mediated tachycardia.
    Lamaison D; Girodo S; Limousin M
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1715-21. PubMed ID: 2463539
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.