108 related articles for article (PubMed ID: 23891958)
1. Palpitations in a patient with a dual-chamber pacemaker: what is the mechanism? Santangeli P; Tsiperfal A; Wang PJ; Al-Ahmad A Heart Rhythm; 2013 Dec; 10(12):1824-5. PubMed ID: 23891958 [No Abstract] [Full Text] [Related]
2. Premature ventricular contractions causing pacemaker-mediated tachycardia: a failure of postventricular atrial refractory period after premature ventricular contraction extension? Witteles R; Engel G; Wang PJ; Al-Ahmad A Heart Rhythm; 2005 Dec; 2(12):1389-90. PubMed ID: 16360099 [No Abstract] [Full Text] [Related]
3. Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm. Barold SS; Van Heuverswyn F; Stroobandt RX J Electrocardiol; 2013; 46(2):136-9. PubMed ID: 23399053 [TBL] [Abstract][Full Text] [Related]
4. Ventricular arrhythmias after leadless pacemaker implantation, a case report and systematic review of the literature. Aparisi Á; Sandín-Fuentes M; García-Granja PE; García-Morán E; Rubio J J Cardiovasc Electrophysiol; 2020 Jan; 31(1):227-228. PubMed ID: 31808227 [No Abstract] [Full Text] [Related]
5. Inhibition of ventricular stimulation in patients with dual chamber pacemakers and prolonged AV conduction. Bode F; Wiegand U; Katus HA; Potratz J Pacing Clin Electrophysiol; 1999 Oct; 22(10):1425-31. PubMed ID: 10588143 [TBL] [Abstract][Full Text] [Related]
6. Varying Morphology of QRS Complexes: A Possible Explanation. Laeeq R; Pollet M; Faza N; Birnbaum Y Tex Heart Inst J; 2017 Dec; 44(6):429-430. PubMed ID: 29276447 [No Abstract] [Full Text] [Related]
7. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia. Sharma PS; Kaszala K; Tan AY; Koneru JN; Shepard R; Ellenbogen KA; Huizar JF Heart Rhythm; 2016 Aug; 13(8):1739-47. PubMed ID: 27050909 [TBL] [Abstract][Full Text] [Related]
8. Undersensing of P waves in the presence of an adequate P wave due to automatic postventricular atrial refractory period extension. Wilson JH; Lattner S Pacing Clin Electrophysiol; 1989 Nov; 12(11):1729-32. PubMed ID: 2478971 [TBL] [Abstract][Full Text] [Related]
9. Management of far-field R wave sensing for the avoidance of inappropriate mode switch in dual chamber pacemakers: results of the FFS-test study. Kolb C; Wille B; Maurer D; Schuchert A; Weber R; Schibgilla V; Klein N; Hümmer A; Schmitt C; Zrenner B; J Cardiovasc Electrophysiol; 2006 Sep; 17(9):992-7. PubMed ID: 16948743 [TBL] [Abstract][Full Text] [Related]
10. Differentiating pacemaker-mediated tachycardia from tachycardia due to atrial tracking: utility of V-A-A-V versus V-A-V response after postventricular atrial refractory period extension. Ip JE; Markowitz SM; Liu CF; Cheung JW; Thomas G; Lerman BB Heart Rhythm; 2011 Aug; 8(8):1185-91. PubMed ID: 21376834 [TBL] [Abstract][Full Text] [Related]
12. Undersensing of ventricular tachycardia in a pacemaker patient: What is the mechanism? Monkhouse C; Whittaker-Axon S; Chow AW Pacing Clin Electrophysiol; 2018 May; 41(5):553-556. PubMed ID: 29476536 [No Abstract] [Full Text] [Related]
13. An unusual termination of a wide complex tachycardia. Cassagneau R; Sunni N; Skanes A; Klein GJ J Cardiovasc Electrophysiol; 2014 May; 25(5):549-552. PubMed ID: 24350631 [No Abstract] [Full Text] [Related]
17. Atrial lead malfunction presenting as new onset pacemaker-mediated tachycardia. Barold SS; Stroobandt RX Europace; 2012 Jul; 14(7):1060-1. PubMed ID: 22286204 [TBL] [Abstract][Full Text] [Related]
18. Ventricular tachycardia terminated by an ICD: is there more than what meets the eye? Lau EW; Green MS; Birnie DH; Lemery R; Tang AS Pacing Clin Electrophysiol; 2004 Dec; 27(12):1656-8. PubMed ID: 15613130 [No Abstract] [Full Text] [Related]
19. Idiopathic ventricular tachycardia originating in the great cardiac vein. Meininger GR; Berger RD Heart Rhythm; 2006 Apr; 3(4):464-6. PubMed ID: 16567296 [No Abstract] [Full Text] [Related]
20. A new algorithm for a high level of protection against pacemaker-mediated tachycardia. Lamaison D; Girodo S; Limousin M Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1715-21. PubMed ID: 2463539 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]