These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 2389221)

  • 41. Determination of endotoxin levels and their impact on interleukin-1 generation in continuous ambulatory peritoneal dialysis and hemodialysis.
    Pearson FC; Dubczak J; Weary M; Anderson J
    Blood Purif; 1988; 6(3):207-12. PubMed ID: 3293624
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Errors in the selection of dialysate concentrates cause severe metabolic acidosis during bicarbonate hemodialysis.
    Navarro JF; Mora-Fernández C; Garcia J
    Artif Organs; 1997 Sep; 21(9):966-8. PubMed ID: 9288865
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Endotoxin and bacterial level of dialysate fluid quality.
    Isakozawa Y; Takesawa S; David V
    Contrib Nephrol; 2011; 173():70-75. PubMed ID: 21865778
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Microbiological and endotoxin assays of hemodialysis fluids.
    Bland LA
    Adv Ren Replace Ther; 1995 Jan; 2(1):70-9. PubMed ID: 7614339
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Hemodiafiltration with on-line production of bicarbonate infusate. A new standard for high-efficiency, low-cost dialysis in elderly and uncompliant patients.
    Canaud B; NGuyen QV; Polito C; Stec F; Mion C
    Contrib Nephrol; 1989; 74():91-100. PubMed ID: 2702151
    [No Abstract]   [Full Text] [Related]  

  • 46. Acetate free biofiltration. Effects on peripheral blood monocyte activation and cytokine release.
    Carozzi S; Nasini MG; Caviglia PM; Schelotto C; Santoni O; Atti M
    ASAIO J; 1992; 38(1):52-4. PubMed ID: 1313318
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Chronic and intradialytic effects of high-flux hemodialysis on tumor necrosis factor-alpha production: relationship to endotoxins.
    Mege JL; Sanguedolce MV; Purgus R; Moulin B; Bongrand P; Capo C; Olmer M
    Am J Kidney Dis; 1992 Nov; 20(5):482-8. PubMed ID: 1279968
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Permeability and adsorption capacity of dialysis membranes to lipid A.
    Weber C; Linsberger I; Rafiee-Tehrani M; Falkenhagen D
    Int J Artif Organs; 1997 Mar; 20(3):144-52. PubMed ID: 9151149
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A new central supply system as alternative source for bicarbonate dialysate.
    Rehmert N; Böcker T; Raidt H; Langer K; Graefe H
    Int J Artif Organs; 1992 Jun; 15(6):339-42. PubMed ID: 1639524
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Increased soluble CD14 levels in patients on hemodialysis. Influence of dialysate endotoxin or incompatibility to dialyzer membranes?
    Mitzner S; Stange J; Pichel K; Handschuk I; Korten G; Ehlers M; Schutt C; Schmidt R
    ASAIO J; 1995; 41(3):M707-8. PubMed ID: 8573897
    [No Abstract]   [Full Text] [Related]  

  • 51. Dialysate contamination and back filtration may limit the use of high-flux dialysis membranes.
    Baurmeister U; Travers M; Vienken J; Harding G; Million C; Klein E; Pass T; Wright R
    ASAIO Trans; 1989; 35(3):519-22. PubMed ID: 2597523
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Chronic inflammation in hemodialysis: the role of contaminated dialysate.
    Lonnemann G
    Blood Purif; 2000; 18(3):214-23. PubMed ID: 10859424
    [TBL] [Abstract][Full Text] [Related]  

  • 53. When good water goes bad: how it happens, clinical consequences and possible solutions.
    Lonnemann G
    Blood Purif; 2004; 22(1):124-9. PubMed ID: 14732820
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Bacteriologic studies of bicarbonate dialysate and suitable initial solutions].
    Wachtel D; Thieler H; Lenhardt E
    Z Urol Nephrol; 1987 Aug; 80(8):491-4. PubMed ID: 2825447
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Ultrafiltration of dialysis fluid to obtain a sterile solution during hemodialysis.
    Bambauer R; Walther J; Jung WK
    Blood Purif; 1990; 8(6):309-17. PubMed ID: 2093329
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Bacterial challenge of NISSHO ultrafilter ETF 609: results of in vitro testing.
    Krautzig S; Lonnemann G; Shaldon S; Koch KM
    Artif Organs; 1996 Jul; 20(7):798-800. PubMed ID: 8828771
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: a nationwide cohort study.
    Hasegawa T; Nakai S; Masakane I; Watanabe Y; Iseki K; Tsubakihara Y; Akizawa T
    Am J Kidney Dis; 2015 Jun; 65(6):899-904. PubMed ID: 25641063
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Dialysate bath and QTc interval in patients on chronic maintenance hemodialysis: pilot study of single dialysis effects.
    Di Iorio B; Torraca S; Piscopo C; Sirico ML; Di Micco L; Pota A; Tartaglia D; Berardino L; Morrone LF; Russo D
    J Nephrol; 2012; 25(5):653-60. PubMed ID: 21983985
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Should dialysis machines be disinfected between patients' shifts?
    Stragier A; Jadoul M
    EDTNA ERCA J; 2003; 29(2):73-6. PubMed ID: 14598949
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Biocompatibility of hemodialysis membranes: evaluation in an ovine model.
    Burhop KE; Johnson RJ; Simpson J; Chenoweth DE; Borgia J
    J Lab Clin Med; 1993 Feb; 121(2):276-93. PubMed ID: 8433041
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]