BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 23892532)

  • 1. Seven years of objective and subjective outcomes of transobturator (TVT-O) vaginal tape: why do tapes fail?
    Athanasiou S; Grigoriadis T; Zacharakis D; Skampardonis N; Lourantou D; Antsaklis A
    Int Urogynecol J; 2014 Feb; 25(2):219-25. PubMed ID: 23892532
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tension-free Vaginal Tape-Obturator for Treatment of Pure Urodynamic Stress Urinary Incontinence: Efficacy and Adverse Effects at 10-year Follow-up.
    Serati M; Braga A; Athanasiou S; Tommaselli GA; Caccia G; Torella M; Ghezzi F; Salvatore S
    Eur Urol; 2017 Apr; 71(4):674-679. PubMed ID: 27597239
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single-incision sling compared with transobturator sling for treating stress urinary incontinence: a randomized controlled trial.
    Bianchi-Ferraro AM; Jarmy-Di Bella ZI; Castro Rde A; Bortolini MA; Sartori MG; Girão MJ
    Int Urogynecol J; 2013 Sep; 24(9):1459-65. PubMed ID: 23208003
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.
    Masata J; Svabik K; Zvara K; Hubka P; Toman A; Martan A
    Int Urogynecol J; 2016 Oct; 27(10):1497-505. PubMed ID: 27037563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Randomized trial of a comparison of the efficacy of TVT-O and single-incision tape TVT SECUR systems in the treatment of stress urinary incontinent women--2-year follow-up.
    Masata J; Svabik K; Zvara K; Drahoradova P; El Haddad R; Hubka P; Martan A
    Int Urogynecol J; 2012 Oct; 23(10):1403-12. PubMed ID: 22314891
    [TBL] [Abstract][Full Text] [Related]  

  • 6. TVT-O for the treatment of pure urodynamic stress incontinence: efficacy, adverse effects, and prognostic factors at 5-year follow-up.
    Serati M; Bauer R; Cornu JN; Cattoni E; Braga A; Siesto G; Lizée D; Haab F; Torella M; Salvatore S
    Eur Urol; 2013 May; 63(5):872-8. PubMed ID: 23274106
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between tension-free vaginal tape and transobturator tape in treating stress urinary incontinence after vaginal mesh surgery.
    Lin L; Huang MC; Su TH; Lau HH
    Taiwan J Obstet Gynecol; 2018 Aug; 57(4):528-531. PubMed ID: 30122572
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tension-Free Vaginal Tape Failure After Robotic Sacrocolpopexy and Tension-Free Vaginal Tape for Concomitant Prolapse and Stress Incontinence.
    Osmundsen B; Gregory WT; Denman MA; Adams K; Edwards R; Clark A
    Female Pelvic Med Reconstr Surg; 2015; 21(5):244-8. PubMed ID: 26313492
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tension-free vaginal tape-obturator for the treatment of stress urinary incontinence: a 12-year prospective follow-up.
    Zhang Y; Song X; Zhang Z; Mao M; Ai F; Kang J; Zhu L
    BJU Int; 2019 May; 123(5A):E57-E62. PubMed ID: 30248230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Randomized controlled trial comparing TVT-O and TVT-S for the treatment of stress urinary incontinence: 2-year results.
    Bianchi-Ferraro AM; Jarmy-DiBella ZI; de Aquino Castro R; Bortolini MA; Sartori MG; Girão MJ
    Int Urogynecol J; 2014 Oct; 25(10):1343-8. PubMed ID: 24643378
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-year follow-up of tension-free vaginal tape compared with transobturator tape in women with stress urinary incontinence and intrinsic sphincter deficiency.
    Schierlitz L; Dwyer PL; Rosamilia A; Murray C; Thomas E; De Souza A; Hiscock R
    Obstet Gynecol; 2012 Feb; 119(2 Pt 1):321-7. PubMed ID: 22270284
    [TBL] [Abstract][Full Text] [Related]  

  • 12. TVT-O for treatment of pure urodynamic stress urinary incontinence: Efficacy and adverse effects at 13-years follow-up.
    Serati M; Braga A; Caccia G; Torella M; Ghezzi F; Salvatore S; Athanasiou S
    Neurourol Urodyn; 2020 Jun; 39(5):1423-1429. PubMed ID: 32282099
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Medium Term Outcomes of TVT-Abbrevo for the Treatment of Stress Urinary Incontinence: Efficacy and Safety at 5-Year Follow-Up.
    Braga A; Castronovo F; Ottone A; Torella M; Salvatore S; Ruffolo AF; Frigerio M; Scancarello C; De Rosa A; Ghezzi F; Papadia A; Caccia G; Serati M
    Medicina (Kaunas); 2022 Oct; 58(10):. PubMed ID: 36295573
    [No Abstract]   [Full Text] [Related]  

  • 14. Retropubic tension-free vaginal tape and inside-out transobturator tape: a long-term randomized trial.
    Zhang Z; Zhu L; Xu T; Lang J
    Int Urogynecol J; 2016 Jan; 27(1):103-11. PubMed ID: 26264474
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ten-Year Followup after Tension-Free Vaginal Tape-Obturator Procedure for Stress Urinary Incontinence.
    Ulrich D; Tammaa A; Hölbfer S; Trutnovsky G; Bjelic-Radisic V; Tamussino K; Aigmüller T
    J Urol; 2016 Oct; 196(4):1201-6. PubMed ID: 27181504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transobturator tape versus retropubic tension-free vaginal tape for stress urinary incontinence: 5-year safety and effectiveness outcomes following a randomised trial.
    Ross S; Tang S; Eliasziw M; Lier D; Girard I; Brennand E; Dederer L; Jacobs P; Robert M
    Int Urogynecol J; 2016 Jun; 27(6):879-86. PubMed ID: 26670575
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of tension-free vaginal tape compared with transobturator tape in women with stress urinary incontinence and intrinsic sphincter deficiency: a randomized controlled trial.
    Schierlitz L; Dwyer PL; Rosamilia A; Murray C; Thomas E; De Souza A; Lim YN; Hiscock R
    Obstet Gynecol; 2008 Dec; 112(6):1253-1261. PubMed ID: 19037033
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tension-free vaginal tape versus tension-free vaginal tape obturator in women with stress urinary incontinence.
    Liapis A; Bakas P; Giner M; Creatsas G
    Gynecol Obstet Invest; 2006; 62(3):160-4. PubMed ID: 16707901
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.
    ElSheemy MS; Fathy H; Hussein HA; Elsergany R; Hussein EA
    Int Urogynecol J; 2015 Oct; 26(10):1533-40. PubMed ID: 25956167
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospective randomised controlled trial of transobturator tapes in management of urodynamic stress incontinence in women: 3-year outcomes from the Evaluation of Transobturator Tapes study.
    Abdel-Fattah M; Mostafa A; Familusi A; Ramsay I; N'dow J
    Eur Urol; 2012 Nov; 62(5):843-51. PubMed ID: 22534058
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.