280 related articles for article (PubMed ID: 23895118)
1. Bone regeneration by the osteoconductivity of porous titanium implants manufactured by selective laser melting: a histological and micro computed tomography study in the rabbit.
de Wild M; Schumacher R; Mayer K; Schkommodau E; Thoma D; Bredell M; Kruse Gujer A; Grätz KW; Weber FE
Tissue Eng Part A; 2013 Dec; 19(23-24):2645-54. PubMed ID: 23895118
[TBL] [Abstract][Full Text] [Related]
2. [Selective Laser Sintering-produced porous titanium alloy scaffold for bone tissue engineering].
Ding R; Wu Z; Qiu G; Wu G; Wang H; Su X; Yin B; Ma S; Qi B
Zhonghua Yi Xue Za Zhi; 2014 May; 94(19):1499-502. PubMed ID: 25143173
[TBL] [Abstract][Full Text] [Related]
3. Fatigue behavior of thin-walled grade 2 titanium samples processed by selective laser melting. Application to life prediction of porous titanium implants.
Lipinski P; Barbas A; Bonnet AS
J Mech Behav Biomed Mater; 2013 Dec; 28():274-90. PubMed ID: 24008139
[TBL] [Abstract][Full Text] [Related]
4. Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting.
Shaoki A; Xu JY; Sun H; Chen XS; Ouyang J; Zhuang XM; Deng FL
Biofabrication; 2016 Oct; 8(4):045014. PubMed ID: 27788123
[TBL] [Abstract][Full Text] [Related]
5. Selective laser melting of titanium alloy enables osseointegration of porous multi-rooted implants in a rabbit model.
Peng W; Xu L; You J; Fang L; Zhang Q
Biomed Eng Online; 2016 Jul; 15(1):85. PubMed ID: 27439427
[TBL] [Abstract][Full Text] [Related]
6. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment.
Taniguchi N; Fujibayashi S; Takemoto M; Sasaki K; Otsuki B; Nakamura T; Matsushita T; Kokubo T; Matsuda S
Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():690-701. PubMed ID: 26652423
[TBL] [Abstract][Full Text] [Related]
7. Performance of laser sintered Ti-6Al-4V implants with bone-inspired porosity and micro/nanoscale surface roughness in the rabbit femur.
Cohen DJ; Cheng A; Sahingur K; Clohessy RM; Hopkins LB; Boyan BD; Schwartz Z
Biomed Mater; 2017 Apr; 12(2):025021. PubMed ID: 28452335
[TBL] [Abstract][Full Text] [Related]
8. Porous titanium granules promote bone healing and growth in rabbit tibia peri-implant osseous defects.
Wohlfahrt JC; Monjo M; Rønold HJ; Aass AM; Ellingsen JE; Lyngstadaas SP
Clin Oral Implants Res; 2010 Feb; 21(2):165-73. PubMed ID: 19912270
[TBL] [Abstract][Full Text] [Related]
9. Fatigue behavior of As-built selective laser melted titanium scaffolds with sheet-based gyroid microarchitecture for bone tissue engineering.
Kelly CN; Francovich J; Julmi S; Safranski D; Guldberg RE; Maier HJ; Gall K
Acta Biomater; 2019 Aug; 94():610-626. PubMed ID: 31125727
[TBL] [Abstract][Full Text] [Related]
10. Continuous functionally graded porous titanium scaffolds manufactured by selective laser melting for bone implants.
Han C; Li Y; Wang Q; Wen S; Wei Q; Yan C; Hao L; Liu J; Shi Y
J Mech Behav Biomed Mater; 2018 Apr; 80():119-127. PubMed ID: 29414467
[TBL] [Abstract][Full Text] [Related]
11. Osteostatin-coated porous titanium can improve early bone regeneration of cortical bone defects in rats.
van der Stok J; Lozano D; Chai YC; Amin Yavari S; Bastidas Coral AP; Verhaar JA; Gómez-Barrena E; Schrooten J; Jahr H; Zadpoor AA; Esbrit P; Weinans H
Tissue Eng Part A; 2015 May; 21(9-10):1495-506. PubMed ID: 25627039
[TBL] [Abstract][Full Text] [Related]
12. Osseointegration of commercial microstructured titanium implants incorporating magnesium: a histomorphometric study in rabbit cancellous bone.
Park JW; An CH; Jeong SH; Suh JY
Clin Oral Implants Res; 2012 Mar; 23(3):294-300. PubMed ID: 21435010
[TBL] [Abstract][Full Text] [Related]
13. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM).
Parthasarathy J; Starly B; Raman S; Christensen A
J Mech Behav Biomed Mater; 2010 Apr; 3(3):249-59. PubMed ID: 20142109
[TBL] [Abstract][Full Text] [Related]
14. Bionic mechanical design and 3D printing of novel porous Ti6Al4V implants for biomedical applications.
Peng WM; Liu YF; Jiang XF; Dong XT; Jun J; Baur DA; Xu JJ; Pan H; Xu X
J Zhejiang Univ Sci B; 2019 Aug.; 20(8):647-659. PubMed ID: 31273962
[TBL] [Abstract][Full Text] [Related]
15. The biocompatibility of dense and porous Nickel-Titanium produced by selective laser melting.
Habijan T; Haberland C; Meier H; Frenzel J; Wittsiepe J; Wuwer C; Greulich C; Schildhauer TA; Köller M
Mater Sci Eng C Mater Biol Appl; 2013 Jan; 33(1):419-26. PubMed ID: 25428090
[TBL] [Abstract][Full Text] [Related]
16. In vivo performance of selective electron beam-melted Ti-6Al-4V structures.
Ponader S; von Wilmowsky C; Widenmayer M; Lutz R; Heinl P; Körner C; Singer RF; Nkenke E; Neukam FW; Schlegel KA
J Biomed Mater Res A; 2010 Jan; 92(1):56-62. PubMed ID: 19165781
[TBL] [Abstract][Full Text] [Related]
17. Bone growth in rapid prototyped porous titanium implants.
Lopez-Heredia MA; Goyenvalle E; Aguado E; Pilet P; Leroux C; Dorget M; Weiss P; Layrolle P
J Biomed Mater Res A; 2008 Jun; 85(3):664-73. PubMed ID: 17876801
[TBL] [Abstract][Full Text] [Related]
18. Enhanced osteoconductivity of micro-structured titanium implants (XiVE S CELLplus) by addition of surface calcium chemistry: a histomorphometric study in the rabbit femur.
Park JW; Kim HK; Kim YJ; An CH; Hanawa T
Clin Oral Implants Res; 2009 Jul; 20(7):684-90. PubMed ID: 19489932
[TBL] [Abstract][Full Text] [Related]
19. The enhancement of bone regeneration by a combination of osteoconductivity and osteostimulation using β-CaSiO3/β-Ca3(PO4)2 composite bioceramics.
Wang C; Xue Y; Lin K; Lu J; Chang J; Sun J
Acta Biomater; 2012 Jan; 8(1):350-60. PubMed ID: 21925627
[TBL] [Abstract][Full Text] [Related]
20. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects.
Van der Stok J; Van der Jagt OP; Amin Yavari S; De Haas MF; Waarsing JH; Jahr H; Van Lieshout EM; Patka P; Verhaar JA; Zadpoor AA; Weinans H
J Orthop Res; 2013 May; 31(5):792-9. PubMed ID: 23255164
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]