218 related articles for article (PubMed ID: 23898612)
1. [Comparison the applications of tracheal intubation with GlideScope video laryngoscope and Macintosh direct laryngoscope in snoring patients]. Ke J; Xu Q Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2013 May; 27(9):468-70. PubMed ID: 23898612 [TBL] [Abstract][Full Text] [Related]
2. [Comparison of hemodynamic responses to nasotracheal intubations with Glide Scope video-laryngoscope, Macintosh direct laryngoscope, and fiberoptic bronchoscope]. Li XY; Xue FS; Sun L; Xu YC; Liu Y; Zhang GH; Li CW; Liu KP; Sun HT Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2007 Feb; 29(1):117-23. PubMed ID: 17380681 [TBL] [Abstract][Full Text] [Related]
3. Comparison of hemodynamic responses to orotracheal intubation with the GlideScope videolaryngoscope and the Macintosh direct laryngoscope. Xue FS; Zhang GH; Li XY; Sun HT; Li P; Li CW; Liu KP J Clin Anesth; 2007 Jun; 19(4):245-50. PubMed ID: 17572317 [TBL] [Abstract][Full Text] [Related]
4. [Comparison of cardiovascular responses between orotracheal and nasotracheal intubation with the aid of GlideScope video laryngoscope]. Liu HP; Xue FS; Li XY; Xu YC; Yang QY Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2008 Jul; 20(7):405-8. PubMed ID: 18611338 [TBL] [Abstract][Full Text] [Related]
5. [Comparison of hemodynamic responses to orotracheal intubation with shikani laryngoscope or macintosh direct laryngoscope]. Zhao SB; Jia NG; Liu KP; Li CH; Zhang YJ; Han L; Xue FS Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2010 Jun; 32(3):303-9. PubMed ID: 20602884 [TBL] [Abstract][Full Text] [Related]
6. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253 [TBL] [Abstract][Full Text] [Related]
7. Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope. Xue FS; Li XY; Liu QJ; Liu HP; Yang QY; Xu YC; Liao X; Liu Y Chin Med J (Engl); 2008 Jul; 121(14):1290-6. PubMed ID: 18713550 [TBL] [Abstract][Full Text] [Related]
8. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Serocki G; Bein B; Scholz J; Dörges V Eur J Anaesthesiol; 2010 Jan; 27(1):24-30. PubMed ID: 19809328 [TBL] [Abstract][Full Text] [Related]
9. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Nouruzi-Sedeh P; Schumann M; Groeben H Anesthesiology; 2009 Jan; 110(1):32-7. PubMed ID: 19104167 [TBL] [Abstract][Full Text] [Related]
10. [Clinical study of SMT-Ⅱ video laryngoscope with difficult airway intubation in emergency department]. Yu JH; Wang Y Zhonghua Wai Ke Za Zhi; 2017 Jul; 55(7):549-553. PubMed ID: 28655086 [No Abstract] [Full Text] [Related]
11. [Tracheal intubation under general anesthesia in patients with difficult laryngoscopy]. Li CW; Xue FS; Deng XM; Xu KL; Tong SY; Liao X Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2004 Dec; 26(6):651-6. PubMed ID: 15663226 [TBL] [Abstract][Full Text] [Related]
12. Tracheal intubation following training with the GlideScope compared to direct laryngoscopy. Ayoub CM; Kanazi GE; Al Alami A; Rameh C; El-Khatib MF Anaesthesia; 2010 Jul; 65(7):674-8. PubMed ID: 20497150 [TBL] [Abstract][Full Text] [Related]
13. Success rates and endotracheal tube insertion times of experienced emergency physicians using five video laryngoscopes: a randomised trial in a simulated trapped car accident victim. Wetsch WA; Carlitscheck M; Spelten O; Teschendorf P; Hellmich M; Genzwürker HV; Hinkelbein J Eur J Anaesthesiol; 2011 Dec; 28(12):849-58. PubMed ID: 21986981 [TBL] [Abstract][Full Text] [Related]
14. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia. Xue FS; Zhang GH; Liu J; Li XY; Yang QY; Xu YC; Li CW Minerva Anestesiol; 2007 Sep; 73(9):451-7. PubMed ID: 17660737 [TBL] [Abstract][Full Text] [Related]
15. Tracheal intubation with the PENTAX-AWS (airway scope) reduces changes of hemodynamic responses and bispectral index scores compared with the Macintosh laryngoscope. Nishikawa K; Matsuoka H; Saito S J Neurosurg Anesthesiol; 2009 Oct; 21(4):292-6. PubMed ID: 19955890 [TBL] [Abstract][Full Text] [Related]
16. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. Hirabayashi Y; Seo N J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032 [TBL] [Abstract][Full Text] [Related]
17. [Effects of different nasotracheal intubations in obstructive sleep apnea hypopnea syndrome patients with uvulopalatopharyngoplasty]. Liu WF; He HP; Xie WX; Weng PQ; Li SY Zhonghua Yi Xue Za Zhi; 2012 Nov; 92(43):3067-71. PubMed ID: 23328380 [TBL] [Abstract][Full Text] [Related]
18. Validation of the GlideScope video laryngoscope in pediatric patients. Redel A; Karademir F; Schlitterlau A; Frommer M; Scholtz LU; Kranke P; Kehl F; Roewer N; Lange M Paediatr Anaesth; 2009 Jul; 19(7):667-71. PubMed ID: 19638111 [TBL] [Abstract][Full Text] [Related]
19. Reduced hemodynamic responses to tracheal intubation by the Bonfils retromolar fiberscope: a randomized controlled study. Boker A; Almarakbi WA; Arab AA; Almazrooa AA Middle East J Anaesthesiol; 2011 Oct; 21(3):385-90. PubMed ID: 22428493 [TBL] [Abstract][Full Text] [Related]
20. A comparison between the Bonfils Intubation Fiberscope and McCoy laryngoscope for tracheal intubation in patients with a simulated difficult airway. Abdullah HR; Li-Ming T; Marriott A; Wong TG Anesth Analg; 2013 Nov; 117(5):1217-20. PubMed ID: 24029854 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]