These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 23899127)

  • 1. Confidence intervals of reference limits in small reference sample groups.
    Braun JP; Concordet D; Geffré A; Bourges Abella N; Trumel C
    Vet Clin Pathol; 2013 Sep; 42(3):395-8. PubMed ID: 23899127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.
    Geffré A; Concordet D; Braun JP; Trumel C
    Vet Clin Pathol; 2011 Mar; 40(1):107-12. PubMed ID: 21366659
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analytical goals for the estimation of non-Gaussian reference intervals.
    Hyltoft Petersen P; Gowans EM; Blaabjerg O; Hørder M
    Scand J Clin Lab Invest; 1989 Dec; 49(8):727-37. PubMed ID: 2617130
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimation of reference intervals from small samples: an example using canine plasma creatinine.
    Geffré A; Braun JP; Trumel C; Concordet D
    Vet Clin Pathol; 2009 Dec; 38(4):477-84. PubMed ID: 19473330
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Should we maintain the 95 percent reference intervals in the era of wellness testing? A concept paper.
    Jørgensen LG; Brandslund I; Hyltoft Petersen P
    Clin Chem Lab Med; 2004; 42(7):747-51. PubMed ID: 15327009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.
    Hyltoft Petersen P; Lund F; Fraser CG; Sandberg S; Sölétormos G
    Ann Clin Biochem; 2018 Sep; 55(5):612-615. PubMed ID: 29310466
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Partitioning reference values of several Gaussian subpopulations with unequal prevalence--a procedure with computer program support.
    Gellerstedt M
    Clin Chem Lab Med; 2006; 44(10):1258-63. PubMed ID: 17032139
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of subgroup prevalences on partitioning of Gaussian-distributed reference values.
    Lahti A; Hyltoft Petersen P; Boyd JC
    Clin Chem; 2002 Nov; 48(11):1987-99. PubMed ID: 12406985
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Graphical interpretation of confidence curves in rankit plots.
    Hyltoft Petersen P; Blaabjerg O; Andersen M; Jørgensen LG; Schousboe K; Jensen E
    Clin Chem Lab Med; 2004; 42(7):715-24. PubMed ID: 15327005
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sensitivity and specificity of normality tests and consequences on reference interval accuracy at small sample size: a computer-simulation study.
    Le Boedec K
    Vet Clin Pathol; 2016 Dec; 45(4):648-656. PubMed ID: 27556235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reference interval estimation of small sample sizes: A methodologic comparison using a computer-simulation study.
    Le Boedec K
    Vet Clin Pathol; 2019 Jun; 48(2):335-346. PubMed ID: 31228287
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Regression-based reference limits: determination of sufficient sample size.
    Virtanen A; Kairisto V; Uusipaikka E
    Clin Chem; 1998 Nov; 44(11):2353-8. PubMed ID: 9799764
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Subjective assessment of frequency distribution histograms and consequences on reference interval accuracy for small sample sizes: A computer-simulated study.
    Coisnon C; Mitchell MA; Rannou B; Le Boedec K
    Vet Clin Pathol; 2021 Sep; 50(3):427-441. PubMed ID: 34476826
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Best practices for veterinary toxicologic clinical pathology, with emphasis on the pharmaceutical and biotechnology industries.
    Tomlinson L; Boone LI; Ramaiah L; Penraat KA; von Beust BR; Ameri M; Poitout-Belissent FM; Weingand K; Workman HC; Aulbach AD; Meyer DJ; Brown DE; MacNeill AL; Bolliger AP; Bounous DI
    Vet Clin Pathol; 2013 Sep; 42(3):252-69. PubMed ID: 23889060
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Objective criteria for partitioning Gaussian-distributed reference values into subgroups.
    Lahti A; Hyltoft Petersen P; Boyd JC; Fraser CG; Jørgensen N
    Clin Chem; 2002 Feb; 48(2):338-52. PubMed ID: 11805016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A method is presented to plan the required sample size when estimating regression-based reference limits.
    Bellera CA; Hanley JA
    J Clin Epidemiol; 2007 Jun; 60(6):610-5. PubMed ID: 17493520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The American Society for Veterinary Clinical Pathology Regulatory Affairs Committee's clinical pathology best practices recommendations will impact the discipline of veterinary toxicologic clinical pathology.
    Reagan WJ
    Vet Clin Pathol; 2013 Sep; 42(3):247-9. PubMed ID: 24033798
    [No Abstract]   [Full Text] [Related]  

  • 18. Reference interval studies: what is the maximum number of samples recommended?
    Hawkins RC; Badrick T
    Clin Chem Lab Med; 2013 Nov; 51(11):2161-5. PubMed ID: 23798619
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Centile charts I: new method of assessment for univariate reference intervals.
    Koduah M; Iles TC; Nix BJ
    Clin Chem; 2004 May; 50(5):901-6. PubMed ID: 15016727
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Precise confidence intervals of regression-based reference limits: Method comparisons and sample size requirements.
    Shieh G
    Comput Biol Med; 2017 Dec; 91():191-197. PubMed ID: 29100113
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.