157 related articles for article (PubMed ID: 23900976)
1. Improved quantification precision of human brain short echo-time (1) H magnetic resonance spectroscopy at high magnetic field: a simulation study.
Deelchand DK; Iltis I; Henry PG
Magn Reson Med; 2014 Jul; 72(1):20-5. PubMed ID: 23900976
[TBL] [Abstract][Full Text] [Related]
2. The influence of spatial resolution on the spectral quality and quantification accuracy of whole-brain MRSI at 1.5T, 3T, 7T, and 9.4T.
Motyka S; Moser P; Hingerl L; Hangel G; Heckova E; Strasser B; Eckstein K; Daniel Robinson S; Poser BA; Gruber S; Trattnig S; Bogner W
Magn Reson Med; 2019 Aug; 82(2):551-565. PubMed ID: 30932248
[TBL] [Abstract][Full Text] [Related]
3. Effect of linewidth on estimation of metabolic concentration when using water lineshape spectral model fitting for single voxel proton spectroscopy at 7 T.
Hong D; van Asten JJA; Rankouhi SR; Thielen JW; Norris DG
J Magn Reson; 2019 Jul; 304():53-61. PubMed ID: 31102923
[TBL] [Abstract][Full Text] [Related]
4. In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: metabolite quantification at 4T vs. 7T.
Tkác I; Oz G; Adriany G; Uğurbil K; Gruetter R
Magn Reson Med; 2009 Oct; 62(4):868-79. PubMed ID: 19591201
[TBL] [Abstract][Full Text] [Related]
5. On the use of Cramér-Rao minimum variance bounds for the design of magnetic resonance spectroscopy experiments.
Bolliger CS; Boesch C; Kreis R
Neuroimage; 2013 Dec; 83():1031-40. PubMed ID: 23933043
[TBL] [Abstract][Full Text] [Related]
6. MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T.
Mekle R; Mlynárik V; Gambarota G; Hergt M; Krueger G; Gruetter R
Magn Reson Med; 2009 Jun; 61(6):1279-85. PubMed ID: 19319893
[TBL] [Abstract][Full Text] [Related]
7. Bayesian deep learning-based
Lee HH; Kim H
Magn Reson Med; 2022 Jul; 88(1):38-52. PubMed ID: 35344604
[TBL] [Abstract][Full Text] [Related]
8. Quantification of Cerebral Glucose Concentrations via Detection of the H1-α-Glucose Peak in
Kuribayashi H; Urushibata Y; Imai H; Ahn S; Seethamraju RT; Isa T; Okada T
J Magn Reson Imaging; 2024 Feb; 59(2):661-672. PubMed ID: 37259965
[TBL] [Abstract][Full Text] [Related]
9. Map-based B
Pan JW; Terpstra MJ; Moon CH; Hetherington HP
NMR Biomed; 2023 Dec; 36(12):e5021. PubMed ID: 37586403
[TBL] [Abstract][Full Text] [Related]
10. Uncertainty propagation in absolute metabolite quantification for in vivo MRS of the human brain.
Instrella R; Juchem C
Magn Reson Med; 2024 Apr; 91(4):1284-1300. PubMed ID: 38029371
[TBL] [Abstract][Full Text] [Related]
11. Improving magnetic resonance spectroscopy in the brainstem periaqueductal gray using spectral registration.
Sirucek L; Zoelch N; Schweinhardt P
Magn Reson Med; 2024 Jan; 91(1):28-38. PubMed ID: 37800387
[TBL] [Abstract][Full Text] [Related]
12. Spectral fitting using basis set modified by measured B0 field distribution.
Li N; An L; Shen J
NMR Biomed; 2015 Dec; 28(12):1707-15. PubMed ID: 26503305
[TBL] [Abstract][Full Text] [Related]
13. Metabolite and macromolecule T1 and T2 relaxation times in the rat brain in vivo at 17.2T.
Lopez-Kolkovsky AL; Mériaux S; Boumezbeur F
Magn Reson Med; 2016 Feb; 75(2):503-14. PubMed ID: 25820200
[TBL] [Abstract][Full Text] [Related]
14. Effect of signal-to-noise ratio and spectral linewidth on metabolite quantification at 4 T.
Bartha R
NMR Biomed; 2007 Aug; 20(5):512-21. PubMed ID: 17205487
[TBL] [Abstract][Full Text] [Related]
15. Mapping of brain macromolecules and their use for spectral processing of (1)H-MRSI data with an ultra-short acquisition delay at 7 T.
Považan M; Hangel G; Strasser B; Gruber S; Chmelik M; Trattnig S; Bogner W
Neuroimage; 2015 Nov; 121():126-35. PubMed ID: 26210813
[TBL] [Abstract][Full Text] [Related]
16. Cramér-Rao bounds: an evaluation tool for quantitation.
Cavassila S; Deval S; Huegen C; van Ormondt D; Graveron-Demilly D
NMR Biomed; 2001 Jun; 14(4):278-83. PubMed ID: 11410946
[TBL] [Abstract][Full Text] [Related]
17. Are Cramér-Rao lower bounds an accurate estimate for standard deviations in in vivo magnetic resonance spectroscopy?
Landheer K; Juchem C
NMR Biomed; 2021 Jul; 34(7):e4521. PubMed ID: 33876459
[TBL] [Abstract][Full Text] [Related]
18. B
Juchem C; de Graaf RA
Anal Biochem; 2017 Jul; 529():17-29. PubMed ID: 27293215
[TBL] [Abstract][Full Text] [Related]
19. Interindividual reproducibility of glutamate quantification using 1.5-T proton magnetic resonance spectroscopy.
Jang DP; Lee JM; Lee E; Park S; Kim JJ; Namkoong K; Yoon KJ; Kim IY; Kim SI
Magn Reson Med; 2005 Mar; 53(3):708-12. PubMed ID: 15723390
[TBL] [Abstract][Full Text] [Related]
20. Discrimination between neurochemical and macromolecular signals in human frontal lobes using short echo time proton magnetic resonance spectroscopy.
McLean MA; Simister RJ; Barker GJ; Duncan JS
Faraday Discuss; 2004; 126():93-102; discussion 169-83. PubMed ID: 14992401
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]