BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 23906142)

  • 1. Shear-thinning effects of hemodynamics in patient-specific cerebral aneurysms.
    Gambaruto A; Janela J; Moura A; Sequeira A
    Math Biosci Eng; 2013 Jun; 10(3):649-65. PubMed ID: 23906142
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sensitivity of hemodynamics in a patient specific cerebral aneurysm to vascular geometry and blood rheology.
    Gambaruto AM; Janela J; Moura A; Sequeira A
    Math Biosci Eng; 2011 Apr; 8(2):409-23. PubMed ID: 21631137
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Newtonian and non-Newtonian blood flow in coiled cerebral aneurysms.
    Morales HG; Larrabide I; Geers AJ; Aguilar ML; Frangi AF
    J Biomech; 2013 Sep; 46(13):2158-64. PubMed ID: 23891312
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids.
    Frolov SV; Sindeev SV; Liepsch D; Balasso A
    Technol Health Care; 2016 May; 24(3):317-33. PubMed ID: 26835725
    [TBL] [Abstract][Full Text] [Related]  

  • 5. PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.
    Ford MD; Nikolov HN; Milner JS; Lownie SP; Demont EM; Kalata W; Loth F; Holdsworth DW; Steinman DA
    J Biomech Eng; 2008 Apr; 130(2):021015. PubMed ID: 18412502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of non-newtonian behavior on hemodynamics of cerebral aneurysms.
    Fisher C; Rossmann JS
    J Biomech Eng; 2009 Sep; 131(9):091004. PubMed ID: 19725693
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood flow dynamics in saccular aneurysm models of the basilar artery.
    Valencia AA; Guzmán AM; Finol EA; Amon CH
    J Biomech Eng; 2006 Aug; 128(4):516-26. PubMed ID: 16813443
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biology and hemodynamics of aneurismal vasculopathies.
    Pereira VM; Brina O; Gonzalez AM; Narata AP; Ouared R; Karl-Olof L
    Eur J Radiol; 2013 Oct; 82(10):1606-17. PubMed ID: 23347588
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.
    Funamoto K; Suzuki Y; Hayase T; Kosugi T; Isoda H
    Ann Biomed Eng; 2009 Jun; 37(6):1105-16. PubMed ID: 19350390
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical investigation of the hemodynamics in anatomically realistic lateral cerebral aneurysms.
    Valencia A; Munizaga J; Rivera R; Bravo E
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():2616-21. PubMed ID: 21096182
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of inlet boundary conditions on the local haemodynamics of intracranial aneurysms.
    Marzo A; Singh P; Reymond P; Stergiopulos N; Patel U; Hose R
    Comput Methods Biomech Biomed Engin; 2009 Aug; 12(4):431-44. PubMed ID: 19675980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Newtonian viscosity model could overestimate wall shear stress in intracranial aneurysm domes and underestimate rupture risk.
    Xiang J; Tremmel M; Kolega J; Levy EI; Natarajan SK; Meng H
    J Neurointerv Surg; 2012 Sep; 4(5):351-7. PubMed ID: 21990529
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Contribution of the hemodynamics of A1 dysplasia or hypoplasia to anterior communicating artery aneurysms: a 3-dimensional numerical simulation study.
    Xu L; Zhang F; Wang H; Yu Y
    J Comput Assist Tomogr; 2012; 36(4):421-6. PubMed ID: 22805671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Blood flow dynamics in patient-specific cerebral aneurysm models: the relationship between wall shear stress and aneurysm area index.
    Valencia A; Morales H; Rivera R; Bravo E; Galvez M
    Med Eng Phys; 2008 Apr; 30(3):329-40. PubMed ID: 17556005
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interactive decomposition and mapping of saccular cerebral aneurysms using harmonic functions: its first application with "patient-specific" computational fluid dynamics (CFD) simulations.
    Jiang J; Strother CM
    IEEE Trans Med Imaging; 2013 Feb; 32(2):153-64. PubMed ID: 22955892
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Realistic non-Newtonian viscosity modelling highlights hemodynamic differences between intracranial aneurysms with and without surface blebs.
    Hippelheuser JE; Lauric A; Cohen AD; Malek AM
    J Biomech; 2014 Nov; 47(15):3695-703. PubMed ID: 25446269
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Numerical analysis on hemodynamics of cerebral aneurysm clip].
    Qiu X; Fei Z; Wang W; Cao Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Feb; 29(1):102-6, 111. PubMed ID: 22404017
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of stents and flow diverters on hemodynamics in idealized aneurysm models.
    Seshadhri S; Janiga G; Beuing O; Skalej M; Thévenin D
    J Biomech Eng; 2011 Jul; 133(7):071005. PubMed ID: 21823744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modelling evolution and the evolving mechanical environment of saccular cerebral aneurysms.
    Watton PN; Selimovic A; Raberger NB; Huang P; Holzapfel GA; Ventikos Y
    Biomech Model Mechanobiol; 2011 Feb; 10(1):109-32. PubMed ID: 20496095
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Variability of hemodynamic parameters using the common viscosity assumption in a computational fluid dynamics analysis of intracranial aneurysms.
    Suzuki T; Takao H; Suzuki T; Suzuki T; Masuda S; Dahmani C; Watanabe M; Mamori H; Ishibashi T; Yamamoto H; Yamamoto M; Murayama Y
    Technol Health Care; 2017; 25(1):37-47. PubMed ID: 27497460
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.