These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 23908417)

  • 1. A prospective study of a ceramic-on-metal bearing in total hip arthroplasty. Clinical results, metal ion levels and chromosome analysis at two years.
    Kazi HA; Perera JR; Gillott E; Carroll FA; Briggs TW
    Bone Joint J; 2013 Aug; 95-B(8):1040-4. PubMed ID: 23908417
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A prospective, randomised controlled trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip replacement.
    Schouten R; Malone AA; Tiffen C; Frampton CM; Hooper G
    J Bone Joint Surg Br; 2012 Nov; 94(11):1462-7. PubMed ID: 23109623
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical Results and Metal Ion Levels After Ceramic-on-Metal Total Hip Arthroplasty: A Mean 50-Month Prospective Single-Center Study.
    Yi Z; Bo Z; Bin S; Jing Y; Zongke Z; Fuxing P
    J Arthroplasty; 2016 Feb; 31(2):438-41. PubMed ID: 26515043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective study of ceramic-on-metal bearings in total hip arthroplasty at four-year follow-up: clinical results, metal ion levels, inflammatory factor levels, and liver-kidney function.
    Zeng Y; Zheng B; Shen B; Yang J; Zhou Z; Kang P; Pei F
    J Orthop Sci; 2015 Mar; 20(2):357-63. PubMed ID: 25530245
    [TBL] [Abstract][Full Text] [Related]  

  • 5. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.
    Barlow BT; Ortiz PA; Boles JW; Lee YY; Padgett DE; Westrich GH
    J Arthroplasty; 2017 May; 32(5):1535-1542. PubMed ID: 28190644
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Metal-on-metal hip resurfacing compared with 28-mm diameter metal-on-metal total hip replacement: a randomised study with six to nine years' follow-up.
    Vendittoli PA; Rivière C; Roy AG; Barry J; Lusignan D; Lavigne M
    Bone Joint J; 2013 Nov; 95-B(11):1464-73. PubMed ID: 24151264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Metal-on-polyethylene versus metal-on-metal bearing surfaces in total hip arthroplasty: a prospective randomised study investigating metal ion levels and chromosomal aberrations in peripheral lymphocytes.
    Briggs TW; Hanna SA; Kayani B; Tai S; Pollock RC; Cannon SR; Blunn GW; Carrington RW
    Bone Joint J; 2015 Sep; 97-B(9):1183-91. PubMed ID: 26330583
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Early surveillance of ceramic-on-metal total hip arthroplasty.
    Hill JC; Diamond OJ; O'Brien S; Boldt JG; Stevenson M; Beverland DE
    Bone Joint J; 2015 Mar; 97-B(3):300-5. PubMed ID: 25737511
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
    Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
    J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective randomised controlled trial comparing three alternative bearing surfaces in primary total hip replacement.
    Nikolaou VS; Edwards MR; Bogoch E; Schemitsch EH; Waddell JP
    J Bone Joint Surg Br; 2012 Apr; 94(4):459-65. PubMed ID: 22434459
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal ion levels from well-functioning Birmingham Hip Resurfacings decline significantly at ten years.
    Van Der Straeten C; Van Quickenborne D; De Roest B; Calistri A; Victor J; De Smet K
    Bone Joint J; 2013 Oct; 95-B(10):1332-8. PubMed ID: 24078528
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Increased Serum Ion Levels After Ceramic-on-Metal Bearing Total Hip Arthroplasty: Influence of an Asian Lifestyle.
    Han SB; Oh JK; Jang WY; Choudhary N; Kim HG; Shon WY
    J Arthroplasty; 2018 Mar; 33(3):887-892. PubMed ID: 29174760
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
    Meftah M; Klingenstein GG; Yun RJ; Ranawat AS; Ranawat CS
    J Bone Joint Surg Am; 2013 Jul; 95(13):1193-7. PubMed ID: 23824387
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing: from a single, non-designer surgeon.
    Holland JP; Langton DJ; Hashmi M
    J Bone Joint Surg Br; 2012 Apr; 94(4):471-6. PubMed ID: 22434461
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems.
    Logroscino G; Saracco M; Maccauro G; Urbani A; Ciavardelli D; Consalvo A; Ferraro D; Falez F
    BMC Musculoskelet Disord; 2022 Feb; 22(Suppl 2):1065. PubMed ID: 35193540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Five-year follow-up of a prospective randomised trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip arthroplasty.
    Schouten R; Malone AA; Frampton CM; Tiffen C; Hooper G
    Bone Joint J; 2017 Oct; 99-B(10):1298-1303. PubMed ID: 28963150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
    Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P
    Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ceramic-on-ceramic bearings in young patients: outcomes and activity levels at minimum ten-year follow-up.
    Chana R; Facek M; Tilley S; Walter WK; Zicat B; Walter WL
    Bone Joint J; 2013 Dec; 95-B(12):1603-9. PubMed ID: 24293588
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.