These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 23908417)

  • 21. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty.
    Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M
    Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical Results and Serum Metal Ion Concentrations following Ceramic-on-Metal Total Hip Arthroplasty at a Mean Follow-Up of 60 Months.
    Maurer-Ertl W; Pranckh-Matzke D; Friesenbichler J; Bratschitsch G; Holzer LA; Maier M; Leithner A
    Biomed Res Int; 2017; 2017():3726029. PubMed ID: 28373980
    [No Abstract]   [Full Text] [Related]  

  • 23. Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up.
    Savarino L; Greco M; Cenni E; Cavasinni L; Rotini R; Baldini N; Giunti A
    J Bone Joint Surg Br; 2006 Apr; 88(4):472-6. PubMed ID: 16567781
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings.
    Milošev I; Kovač S; Trebše R; Levašič V; Pišot V
    J Bone Joint Surg Am; 2012 Oct; 94(19):1756-63. PubMed ID: 23032586
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ceramic-on-ceramic total hip arthroplasty: update.
    Capello WN; D'Antonio JA; Feinberg JR; Manley MT; Naughton M
    J Arthroplasty; 2008 Oct; 23(7 Suppl):39-43. PubMed ID: 18922373
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Metal ion levels in ceramic-on-ceramic THR with cobalt-chrome modular necks: analysis of cobalt and chromium serum levels in 23 healthy hip patients.
    Somers JF; Dedrye L; Goeminne S
    Hip Int; 2017 Feb; 27(1):21-25. PubMed ID: 27791242
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Minimum 5-year results of modular metal-on-metal total hip arthroplasty.
    Kindsfater KA; Sychterz Terefenko CJ; Gruen TA; Sherman CM
    J Arthroplasty; 2012 Apr; 27(4):545-50. PubMed ID: 21908166
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Blood metal levels, leucocyte profiles, and cytokine profiles in patients with a modular dual-mobility hip prosthesis: early results from a prospective cohort study.
    Markel DC; Bou-Akl T; Rossi MD; Pizzimenti N; Wu B; Ren W
    Bone Joint J; 2019 Sep; 101-B(9):1035-1041. PubMed ID: 31474131
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An Early Report of the Use of a Modular Dual Mobility Articulation in Revision Acetabular Reconstruction.
    Diamond OJ; Konan S; Greidanus NV; Garbuz DS; Duncan CP; Masri BS
    J Arthroplasty; 2018 Sep; 33(9):2961-2966. PubMed ID: 29807791
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Serum ion levels after ceramic-on-ceramic and metal-on-metal total hip arthroplasty: 8-year minimum follow-up.
    Savarino L; Padovani G; Ferretti M; Greco M; Cenni E; Perrone G; Greco F; Baldini N; Giunti A
    J Orthop Res; 2008 Dec; 26(12):1569-76. PubMed ID: 18634038
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Early to mid-term results of ceramic-on-ceramic total hip replacement: analysis of bearing-surface-related complications.
    Stafford GH; Islam SU; Witt JD
    J Bone Joint Surg Br; 2011 Aug; 93(8):1017-20. PubMed ID: 21768622
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Serum aluminium and cobalt levels after ceramic-on-ceramic and metal-on-metal total hip replacement.
    Grübl A; Weissinger M; Brodner W; Gleiss A; Giurea A; Gruber M; Pöll G; Meisinger V; Gottsauner-Wolf F; Kotz R
    J Bone Joint Surg Br; 2006 Aug; 88(8):1003-5. PubMed ID: 16877596
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Metal ion levels in ceramic-on-ceramic THR with modular necks: analysis of cobalt and chromium serum levels in 30 healthy hip patients.
    Somers JF
    Hip Int; 2015; 25(5):484-7. PubMed ID: 26391261
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Raised levels of metal ions in the blood in patients who have undergone uncemented metal-on-polyethylene Trident-Accolade total hip replacement.
    Craig P; Bancroft G; Burton A; Collier S; Shaylor P; Sinha A
    Bone Joint J; 2014 Jan; 96-B(1):43-7. PubMed ID: 24395309
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.
    Isaac GH; Brockett C; Breckon A; van der Jagt D; Williams S; Hardaker C; Fisher J; Schepers A
    J Bone Joint Surg Br; 2009 Sep; 91(9):1134-41. PubMed ID: 19721036
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Similar incidence of periprosthetic fluid collections after ceramic-on-polyethylene total hip arthroplasties and metal-on-metal resurfacing arthroplasties: results of a screening metal artefact reduction sequence-MRI study.
    Bisseling P; de Wit BW; Hol AM; van Gorp MJ; van Kampen A; van Susante JL
    Bone Joint J; 2015 Sep; 97-B(9):1175-82. PubMed ID: 26330582
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The significance of metal staining on alumina femoral heads in total hip arthroplasty.
    Bal BS; Rahaman MN; Aleto T; Miller FS; Traina F; Toni A
    J Arthroplasty; 2007 Jan; 22(1):14-9. PubMed ID: 17197303
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in patients less than fifty years of age: a comparative study with twelve to fourteen-year follow-up.
    Migaud H; Putman S; Krantz N; Vasseur L; Girard J
    J Bone Joint Surg Am; 2011 May; 93 Suppl 2():137-42. PubMed ID: 21543703
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Squeaking in a Delta ceramic-on-ceramic uncemented total hip arthroplasty.
    Buttaro MA; Zanotti G; Comba FM; Piccaluga F
    J Arthroplasty; 2012 Jun; 27(6):1257-9. PubMed ID: 22397859
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ceramic-on-metal bearing in short stem total hip arthroplasty: ions, functional and radiographic evaluation at mid-term follow-up.
    Saracco M; Maccauro G; Urbani A; Ciavardelli D; Persichilli S; Ancillai G; Pasqualetti P; Calvisi V; Logroscino G
    Hip Int; 2020 Dec; 30(2_suppl):52-58. PubMed ID: 33267696
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.