293 related articles for article (PubMed ID: 23912908)
1. Mechanical failure of single cannulated screw fixation of unstable slipped capital femoral epiphysis.
Slone HS; Stacey SC; Mooney JF
J Pediatr Orthop B; 2014 Jan; 23(1):49-54. PubMed ID: 23912908
[TBL] [Abstract][Full Text] [Related]
2. Intraoperative Monitoring of Epiphyseal Perfusion in Slipped Capital Femoral Epiphysis.
Schrader T; Jones CR; Kaufman AM; Herzog MM
J Bone Joint Surg Am; 2016 Jun; 98(12):1030-40. PubMed ID: 27307364
[TBL] [Abstract][Full Text] [Related]
3. Similar femoral growth and deformity with one screw versus two smooth pins for slipped capital femoral epiphysis.
Megaloikonomos PD; Mavrogenis AF; Panagopoulos GN; Igoumenou VG; Giakas G; Zampakides C; Pasparakis D
Int Orthop; 2019 Jul; 43(7):1627-1634. PubMed ID: 30039196
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical Testing of Unstable Slipped Capital Femoral Epiphysis Screw Fixation: Worth the Risk of a Second Screw?
Schmitz MR; Farnsworth CL; Doan JD; Glaser DA; Scannell BP; Edmonds EW
J Pediatr Orthop; 2015; 35(5):496-500. PubMed ID: 25171682
[TBL] [Abstract][Full Text] [Related]
5. Current Practice in the Management of Slipped Capital Femoral Epiphysis.
Thawrani DP; Feldman DS; Sala DA
J Pediatr Orthop; 2016; 36(3):e27-37. PubMed ID: 25929770
[TBL] [Abstract][Full Text] [Related]
6. [Growth and deformity after in situ fixation of slipped capital femoral epiphysis].
Druschel C; Placzek R; Funk JF
Z Orthop Unfall; 2013 Aug; 151(4):371-9. PubMed ID: 23963984
[TBL] [Abstract][Full Text] [Related]
7. Diagnosis and treatment of slipped capital femoral epiphysis: Recent trends to note.
Otani T; Kawaguchi Y; Marumo K
J Orthop Sci; 2018 Mar; 23(2):220-228. PubMed ID: 29361376
[TBL] [Abstract][Full Text] [Related]
8. Oblique in situ screw fixation of stable slipped capital femoral epiphysis.
Gourineni P
J Pediatr Orthop; 2013 Mar; 33(2):135-8. PubMed ID: 23389566
[TBL] [Abstract][Full Text] [Related]
9. [Slipped capital femoral epiphysis].
Martínez-Álvarez S; Martínez-González C; Miranda Gorozarri C; Abril JC; Epeldegui T
Rev Esp Cir Ortop Traumatol; 2012; 56(6):506-14. PubMed ID: 23594949
[TBL] [Abstract][Full Text] [Related]
10. What are the risks of prophylactic pinning to prevent contralateral slipped capital femoral epiphysis?
Sankar WN; Novais EN; Lee C; Al-Omari AA; Choi PD; Shore BJ
Clin Orthop Relat Res; 2013 Jul; 471(7):2118-23. PubMed ID: 23129473
[TBL] [Abstract][Full Text] [Related]
11. Technique for rapid identification and removal of slipped capital femoral epiphysis screws.
Fillingham YA; Kogan M
Am J Orthop (Belle Mead NJ); 2014 May; 43(5):238-9. PubMed ID: 24839632
[TBL] [Abstract][Full Text] [Related]
12. The Free-Gliding screw for slipped capital femoral epiphysis : is it safe, does it glide, and does age matter?
Buchan SJ; Lindisfarne EA; Stabler A; Barry M; Gent ED; Bennet S; Aarvold A
Bone Joint J; 2023 Feb; 105-B(2):215-219. PubMed ID: 36722064
[TBL] [Abstract][Full Text] [Related]
13. Significantly lower femoral neck growth in screw fixation of the asymptomatic contralateral hip in unilateral slipped capital femoral epiphysis.
Wölfle-Roos JV; Urlaub S; Reichel H; Taurman R
J Pediatr Orthop B; 2016 May; 25(3):197-201. PubMed ID: 26919622
[TBL] [Abstract][Full Text] [Related]
14. The outcome of in-situ fixation of unstable slipped capital femoral epiphysis.
Lang P; Panchal H; Delfosse EM; Silva M
J Pediatr Orthop B; 2019 Sep; 28(5):452-457. PubMed ID: 30702638
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical Comparison of Perpendicular Versus Oblique In Situ Screw Fixation of Slipped Capital Femoral Epiphysis.
Merz MK; Amirouche F; Solitro GF; Silverstein JA; Surma T; Gourineni PV
J Pediatr Orthop; 2015 Dec; 35(8):816-20. PubMed ID: 25526584
[TBL] [Abstract][Full Text] [Related]
16. Modified Dunn Procedure is Superior to In Situ Pinning for Short-term Clinical and Radiographic Improvement in Severe Stable SCFE.
Novais EN; Hill MK; Carry PM; Heare TC; Sink EL
Clin Orthop Relat Res; 2015 Jun; 473(6):2108-17. PubMed ID: 25502479
[TBL] [Abstract][Full Text] [Related]
17. Screw Thread Configuration Has No Effect on Outcomes of In Situ Fixation for Stable Slipped Capital Femoral Epiphysis.
Via GG; Brueggeman DA; Lyons JG; Edukugho DO; Froehle AW; Martinek MA; Albert MC
J Pediatr Orthop; 2022 Aug; 42(7):e767-e771. PubMed ID: 35671226
[TBL] [Abstract][Full Text] [Related]
18. Mechanical Failure of 2 Cannulated Screw Fixation for Unstable SCFE: A Case Report.
Levey ST; Goodloe JB; Murphy RF; Van Nortwick S
JBJS Case Connect; 2021 Dec; 11(4):. PubMed ID: 34910713
[TBL] [Abstract][Full Text] [Related]
19. Current concepts in management of slipped capital femoral epiphysis.
Bittersohl B; Hosalkar HS; Zilkens C; Krauspe R
Hip Int; 2015; 25(2):104-14. PubMed ID: 25362879
[TBL] [Abstract][Full Text] [Related]
20. Treatment of Unstable Slipped Capital Epiphysis Via the Modified Dunn Procedure.
Persinger F; Davis RL; Samora WP; Klingele KE
J Pediatr Orthop; 2018 Jan; 38(1):3-8. PubMed ID: 26866640
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]