These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
43. Flow injection photometric determination of NaCl, KCl and glucose in injectable drugs exploiting Schlieren signals. Diniz PH; de Melo KD; Fagundes YN; de Araujo Gomes A; do Nascimento EC; dos Santos SR; de Almeida LF; de Araújo MC J Pharm Biomed Anal; 2012 Mar; 62():172-6. PubMed ID: 22244731 [TBL] [Abstract][Full Text] [Related]
44. Heat-conduction error of temperature sensors in a fluid flow with nonuniform and unsteady temperature distribution. Khine SM; Houra T; Tagawa M Rev Sci Instrum; 2013 Apr; 84(4):044902. PubMed ID: 23635222 [TBL] [Abstract][Full Text] [Related]
45. Temperature-dependent schlieren effect in liquid flow for chemical analysis. Suwanrut J; Chantipmanee N; Kamsong W; Buking S; Mantim T; Saetear P; Nacapricha D Talanta; 2018 Oct; 188():74-80. PubMed ID: 30029441 [TBL] [Abstract][Full Text] [Related]
46. New dimension in the schlieren technique: flow field analysis using color. Maddox AR; Binder RC Appl Opt; 1971 Mar; 10(3):474-81. PubMed ID: 20094475 [TBL] [Abstract][Full Text] [Related]
47. Comparative study of denaturation of whey protein isolate (WPI) in convective air drying and isothermal heat treatment processes. Haque MA; Aldred P; Chen J; Barrow CJ; Adhikari B Food Chem; 2013 Nov; 141(2):702-11. PubMed ID: 23790837 [TBL] [Abstract][Full Text] [Related]
48. Using Schlieren Imaging and a Radar Acoustic Sounding System for the Detection of Close-in Air Turbulence. Gordon S; Brooker G Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837085 [TBL] [Abstract][Full Text] [Related]
49. Background-oriented schlieren sensitivity in terms of geometrical parameters of measurement setup. Koponen E; Leskinen J; Tarvainen T; Pulkkinen A J Acoust Soc Am; 2023 Dec; 154(6):3726-3736. PubMed ID: 38088747 [TBL] [Abstract][Full Text] [Related]
50. A new predictive dynamic model describing the effect of the ambient temperature and the convective heat transfer coefficient on bacterial growth. Ben Yaghlene H; Leguerinel I; Hamdi M; Mafart P Int J Food Microbiol; 2009 Jul; 133(1-2):48-61. PubMed ID: 19447512 [TBL] [Abstract][Full Text] [Related]
51. Single beam schlieren interferometer using a wollaston prism. Small RD; Sernas VA; Page RH Appl Opt; 1972 Apr; 11(4):858-62. PubMed ID: 20119058 [TBL] [Abstract][Full Text] [Related]
52. A transistor based air flow transducer for thermohygrometric control of neonatal ventilatory applications. Schena E; Silvestri S Rev Sci Instrum; 2008 Oct; 79(10):104301. PubMed ID: 19044734 [TBL] [Abstract][Full Text] [Related]