These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 2391429)

  • 1. Preparation and characterization of xanthine oxidase-antibody and -hapten conjugates for use in sensitive chemiluminescent immunoassays.
    Fert V; Baret A
    J Immunol Methods; 1990 Aug; 131(2):237-47. PubMed ID: 2391429
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Synthesis and evaluation of luminescent tracers and hapten-protein conjugates for use in luminescence immunoassays with immobilised antibodies and antigens. A critical study of macro solid phases for use in immunoassay systems, Part II.
    Gadow A; Fricke H; Strasburger CJ; Wood WG
    J Clin Chem Clin Biochem; 1984 May; 22(5):337-47. PubMed ID: 6470624
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of a long-term enhanced xanthine oxidase-induced luminescence in solid-phase immunoassays.
    Baret A; Fert V; Aumaille J
    Anal Biochem; 1990 May; 187(1):20-6. PubMed ID: 2115311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. T4 and ultrasensitive TSH immunoassays using luminescent enhanced xanthine oxidase assay.
    Baret A; Fert V
    J Biolumin Chemilumin; 1989 Jul; 4(1):149-53. PubMed ID: 2678912
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of xanthine oxidase-catalyzed luminol chemiluminescence in a mouse interleukin-5 immunoassay.
    Rongen HA; van der Horst HM; van Oosterhout AJ; Bult A; van Bennekom WP
    J Immunol Methods; 1996 Oct; 197(1-2):161-9. PubMed ID: 8890903
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Antibody engineering-based approach for hapten immunometric assays with high sensitivity].
    Kobayashi N; Kato Y; Oyama H; Goto J
    Yakugaku Zasshi; 2007 Jan; 127(1):55-69. PubMed ID: 17202785
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chemiluminescent labelled streptavidin (STAV) as a universal marker in steroid and peptide immunoassays.
    Strasburger CJ; Kohen F
    J Biolumin Chemilumin; 1989 Jul; 4(1):112-8. PubMed ID: 2801206
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of N-(aminobenzoyloxy) succinimide as a two-level heterobifunctional agent for the preparation of hapten-protein conjugates. Daunomycin as a model hapten with an amino group.
    Fujiwara K; Matsumoto N; Kitagawa T; Inouye K
    J Immunol Methods; 1990 Dec; 134(2):227-35. PubMed ID: 2254668
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Prospects for use of hapten-heterologous conjugates in immunoassay of thyroid hormones].
    Danilova NP; Mertts MV; Lokshin DR; Vasilov RG
    Bioorg Khim; 1996 Jan; 22(1):34-8. PubMed ID: 8651954
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chemiluminescent determination of xanthine oxidase activity in milk.
    Girotti S; Lodi S; Ferri E; Lasi G; Fini F; Ghini S; Budini R
    J Dairy Res; 1999 Aug; 66(3):441-8. PubMed ID: 10480082
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of acridinium-9-carboxamides and anti-acridinium antibodies for chemiluminescent signal enhancement.
    Adamczyk M; Mattingly PG; Moore JA; Pan Y; Shreder K; Yu Z
    Bioconjug Chem; 2001; 12(3):329-31. PubMed ID: 11353528
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noncompetitive immunoassay detection system for haptens on the basis of antimetatype antibodies.
    Omi K; Ando T; Sakyu T; Shirakawa T; Uchida Y; Oka A; Ise N; Aoyagi K; Goishi K
    Clin Chem; 2015 Apr; 61(4):627-35. PubMed ID: 25695852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics and detection principles of a new enzyme label producing a long-term chemiluminescent signal.
    Jansen EH; van den Berg RH; Zomer G
    J Biolumin Chemilumin; 1989 Jul; 4(1):129-35. PubMed ID: 2678911
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Immunohistochemical localization of xanthine oxidase in human retina.
    Fox NE; van Kuijk FJ
    Free Radic Biol Med; 1998 Apr; 24(6):900-5. PubMed ID: 9607599
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Enhancement of the sensitivity of a chemiluminescent immunoassay for estradiol based on hapten heterology.
    Sato H; Mochizuki H; Tomita Y; Kanamori T
    Clin Biochem; 1996 Dec; 29(6):509-13. PubMed ID: 8939397
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enzyme-amplified lanthanide luminescence for enzyme detection in bioanalytical assays.
    Evangelista RA; Pollak A; Templeton EF
    Anal Biochem; 1991 Aug; 197(1):213-24. PubMed ID: 1952068
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of xanthine oxidase in human serum by a competitive enzyme-linked immunosorbent assay (ELISA).
    Battelli MG; Abbondanza A; Musiani S; Buonamici L; Strocchi P; Tazzari PL; Gramantieri L; Stirpe F
    Clin Chim Acta; 1999 Mar; 281(1-2):147-58. PubMed ID: 10217635
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A label-free strategy for measuring the affinity between monoclonal antibody and hapten using microdialysis sampling combined with chemiluminescent detection.
    Zhou Y; Wang P; Xiong J; Yue H; He Y; Ouyang H; Wang L; Fu Z
    Biosens Bioelectron; 2017 Jan; 87():404-409. PubMed ID: 27589403
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of Immunoassays for Type II Synthetic Pyrethroids. 1. Hapten Design and Application to Heterologous and Homologous Assays.
    Lee N; McAdam DP; Skerritt JH
    J Agric Food Chem; 1998 Feb; 46(2):520-534. PubMed ID: 10554273
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hapten modification approach for switching immunoassay specificity from selective to generic.
    Burkin MA; Galvidis IA
    J Immunol Methods; 2013 Feb; 388(1-2):60-7. PubMed ID: 23234756
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.