155 related articles for article (PubMed ID: 23921827)
1. An inexpensive method for kinematic calibration of a parallel robot by using one hand-held camera as main sensor.
Traslosheros A; Sebastián JM; Torrijos J; Carelli R; Castillo E
Sensors (Basel); 2013 Aug; 13(8):9941-65. PubMed ID: 23921827
[TBL] [Abstract][Full Text] [Related]
2. A vision-based self-calibration method for robotic visual inspection systems.
Yin S; Ren Y; Zhu J; Yang S; Ye S
Sensors (Basel); 2013 Dec; 13(12):16565-82. PubMed ID: 24300597
[TBL] [Abstract][Full Text] [Related]
3. A new full pose measurement method for robot calibration.
Nguyen HN; Zhou J; Kang HJ
Sensors (Basel); 2013 Jul; 13(7):9132-47. PubMed ID: 23863856
[TBL] [Abstract][Full Text] [Related]
4. Robust real-time robot-world calibration for robotized transcranial magnetic stimulation.
Richter L; Ernst F; Schlaefer A; Schweikard A
Int J Med Robot; 2011 Dec; 7(4):414-22. PubMed ID: 21834131
[TBL] [Abstract][Full Text] [Related]
5. Fast Kinematic Re-Calibration for Industrial Robot Arms.
Kana S; Gurnani J; Ramanathan V; Turlapati SH; Ariffin MZ; Campolo D
Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336465
[TBL] [Abstract][Full Text] [Related]
6. Precision Denavit-Hartenberg Parameter Calibration for Industrial Robots Using a Laser Tracker System and Intelligent Optimization Approaches.
Khanesar MA; Yan M; Isa M; Piano S; Branson DT
Sensors (Basel); 2023 Jun; 23(12):. PubMed ID: 37420535
[TBL] [Abstract][Full Text] [Related]
7. An intelligent space for mobile robot localization using a multi-camera system.
Rampinelli M; Covre VB; de Queiroz FM; Vassallo RF; Bastos-Filho TF; Mazo M
Sensors (Basel); 2014 Aug; 14(8):15039-64. PubMed ID: 25196009
[TBL] [Abstract][Full Text] [Related]
8. Calibration of a laser galvanometric scanning system by adapting a camera model.
Cui S; Zhu X; Wang W; Xie Y
Appl Opt; 2009 May; 48(14):2632-7. PubMed ID: 19424382
[TBL] [Abstract][Full Text] [Related]
9. IMU-based online kinematic calibration of robot manipulator.
Du G; Zhang P
ScientificWorldJournal; 2013; 2013():139738. PubMed ID: 24302854
[TBL] [Abstract][Full Text] [Related]
10. Geometric Parameter Calibration for a Cable-Driven Parallel Robot Based on a Single One-Dimensional Laser Distance Sensor Measurement and Experimental Modeling.
Jin X; Jung J; Ko SY; Choi E; Park JO; Kim CS
Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 30041466
[TBL] [Abstract][Full Text] [Related]
11. Thermal tracking in mobile robots for leak inspection activities.
Ibarguren A; Molina J; Susperregi L; Maurtua I
Sensors (Basel); 2013 Oct; 13(10):13560-74. PubMed ID: 24113684
[TBL] [Abstract][Full Text] [Related]
12. Joint Calibration Method for Robot Measurement Systems.
Wu L; Zang X; Ding G; Wang C; Zhang X; Liu Y; Zhao J
Sensors (Basel); 2023 Aug; 23(17):. PubMed ID: 37687903
[TBL] [Abstract][Full Text] [Related]
13. Kinematic model calibration of a collaborative redundant robot using a closed kinematic chain.
Petrič T; Žlajpah L
Sci Rep; 2023 Oct; 13(1):17804. PubMed ID: 37853070
[TBL] [Abstract][Full Text] [Related]
14. Homography-based visual servo regulation of mobile robots.
Fang Y; Dixon WE; Dawson DM; Chawda P
IEEE Trans Syst Man Cybern B Cybern; 2005 Oct; 35(5):1041-50. PubMed ID: 16240777
[TBL] [Abstract][Full Text] [Related]
15. Multi sensor fusion framework for indoor-outdoor localization of limited resource mobile robots.
Marín L; Vallés M; Soriano Á; Valera Á; Albertos P
Sensors (Basel); 2013 Oct; 13(10):14133-60. PubMed ID: 24152933
[TBL] [Abstract][Full Text] [Related]
16. System design of a hand-held mobile robot for craniotomy.
Kane G; Eggers G; Boesecke R; Raczkowsky J; Wörn H; Marmulla R; Mühling J
Med Image Comput Comput Assist Interv; 2009; 12(Pt 1):402-9. PubMed ID: 20426013
[TBL] [Abstract][Full Text] [Related]
17. Development of a 3D parallel mechanism robot arm with three vertical-axial pneumatic actuators combined with a stereo vision system.
Chiang MH; Lin HT
Sensors (Basel); 2011; 11(12):11476-94. PubMed ID: 22247676
[TBL] [Abstract][Full Text] [Related]
18. Development of robot hand with pneumatic actuator and construct of master-slave system.
Nishino S; Tsujiuchi N; Koizumi T; Komatsubara H; Kudawara T; Shimizu M
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3027-30. PubMed ID: 18002632
[TBL] [Abstract][Full Text] [Related]
19. Simultaneous Calibration of the Hand-Eye, Flange-Tool and Robot-Robot Relationship in Dual-Robot Collaboration Systems.
Qin Y; Geng P; Lv B; Meng Y; Song Z; Han J
Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35271007
[TBL] [Abstract][Full Text] [Related]
20. Kinematic Calibration of a Cable-Driven Parallel Robot for 3D Printing.
Qian S; Bao K; Zi B; Wang N
Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30200475
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]