BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

404 related articles for article (PubMed ID: 23927298)

  • 1. Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning.
    Paudel MR; Mackenzie M; Fallone BG; Rathee S
    Med Phys; 2013 Aug; 40(8):081701. PubMed ID: 23927298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical evaluation of normalized metal artifact reduction in kVCT using MVCT prior images (MVCT-NMAR) for radiation therapy treatment planning.
    Paudel MR; Mackenzie M; Fallone BG; Rathee S
    Int J Radiat Oncol Biol Phys; 2014 Jul; 89(3):682-9. PubMed ID: 24751408
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of metal artifacts in MVCT systems using a model based correction method.
    Paudel MR; Mackenzie M; Fallone BG; Rathee S
    Med Phys; 2012 Oct; 39(10):6297-308. PubMed ID: 23039665
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal artifact reduction through MVCBCT and kVCT in radiotherapy.
    Liugang G; Hongfei S; Xinye N; Mingming F; Zheng C; Tao L
    Sci Rep; 2016 Nov; 6():37608. PubMed ID: 27869185
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Normalized metal artifact reduction in head and neck computed tomography.
    Lell MM; Meyer E; Kuefner MA; May MS; Raupach R; Uder M; Kachelriess M
    Invest Radiol; 2012 Jul; 47(7):415-21. PubMed ID: 22659592
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Changes realized from extended bit-depth and metal artifact reduction in CT.
    Glide-Hurst C; Chen D; Zhong H; Chetty IJ
    Med Phys; 2013 Jun; 40(6):061711. PubMed ID: 23718590
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of metal artifact reduction on the retrieval of attenuation values.
    Ziemann C; Stille M; Cremers F; Rades D; Buzug TM
    J Appl Clin Med Phys; 2017 Jan; 18(1):243-250. PubMed ID: 28291909
    [TBL] [Abstract][Full Text] [Related]  

  • 8. KVCT, MVCT, and hybrid CT image studies--treatment planning and dose delivery equivalence on helical tomotherapy.
    Martin S; Yartsev S
    Med Phys; 2010 Jun; 37(6):2847-54. PubMed ID: 20632596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new approach for reducing beam hardening artifacts in polychromatic X-ray computed tomography using more accurate prior image.
    Wang H; Xu Y; Shi H
    J Xray Sci Technol; 2018; 26(4):593-602. PubMed ID: 29562575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses.
    Chapman D; Smith S; Barnett R; Bauman G; Yartsev S
    Radiat Oncol; 2014 Feb; 9():43. PubMed ID: 24491230
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants?
    Newhauser WD; Giebeler A; Langen KM; Mirkovic D; Mohan R
    Phys Med Biol; 2008 May; 53(9):2327-44. PubMed ID: 18421122
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Normalized metal artifact reduction (NMAR) in computed tomography.
    Meyer E; Raupach R; Lell M; Schmidt B; Kachelriess M
    Med Phys; 2010 Oct; 37(10):5482-93. PubMed ID: 21089784
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography.
    Yang M; Virshup G; Mohan R; Shaw CC; Zhu XR; Dong L
    Med Phys; 2008 May; 35(5):1932-41. PubMed ID: 18561669
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer tomography].
    Gao L; Sun H; Lin T; Sui J; Ni X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2017 Oct; 34(5):730-737. PubMed ID: 29761959
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SU-E-J-17: Evaluation of Metal Artifact Reduction in MVCTs Using a Model Based Image Reconstruction Method.
    Paudel M; MacKenzie M; Fallone B; Rathee S
    Med Phys; 2012 Jun; 39(6Part6):3655-3656. PubMed ID: 28517570
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy.
    Axente M; Paidi A; Von Eyben R; Zeng C; Bani-Hashemi A; Krauss A; Hristov D
    Med Phys; 2015 Mar; 42(3):1170-83. PubMed ID: 25735272
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal artifact correction in photon-counting detector computed tomography: metal trace replacement using high-energy data.
    Richtsmeier D; O'Connell J; Rodesch PA; Iniewski K; Bazalova-Carter M
    Med Phys; 2023 Jan; 50(1):380-396. PubMed ID: 36227611
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose perturbation caused by metallic port in breast tissue expander in proton beam therapy.
    Zhao L; Moskvin VP; Cheng CW; Das IJ
    Biomed Phys Eng Express; 2020 Nov; 6(6):. PubMed ID: 34035189
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.
    Ziemann C; Stille M; Cremers F; Buzug TM; Rades D
    J Appl Clin Med Phys; 2018 May; 19(3):227-233. PubMed ID: 29664225
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric assessment of a single-energy metal artifact reduction algorithm for computed tomography images in radiation therapy.
    Murazaki H; Fukunaga J; Hirose TA; Funatsu N; Matsumoto R; Hidaka K; Nagamine S; Nakanishi D; Kato T
    Radiol Phys Technol; 2019 Sep; 12(3):268-276. PubMed ID: 31140058
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.