These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
146 related articles for article (PubMed ID: 23927339)
41. Small field output factor measurement and verification for CyberKnife robotic radiotherapy and radiosurgery system using 3D polymer gel, ionization chamber, diode, diamond and scintillator detectors, Gafchromic film and Monte Carlo simulation. Al Kafi MA; Arib M; Al Moussa A; Alzorkany F; Shehadeh M; Mohd Yusof MF; Moftah B Appl Radiat Isot; 2023 Feb; 192():110576. PubMed ID: 36473319 [TBL] [Abstract][Full Text] [Related]
42. Energy response corrections for profile measurements using a combination of different detector types. Wegener S; Sauer OA Med Phys; 2018 Feb; 45(2):898-907. PubMed ID: 29193168 [TBL] [Abstract][Full Text] [Related]
43. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields. Czarnecki D; Zink K Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734 [TBL] [Abstract][Full Text] [Related]
44. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams. Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073 [TBL] [Abstract][Full Text] [Related]
45. A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry. Damodar J; Odgers D; Pope D; Hill R Appl Radiat Isot; 2018 May; 135():104-109. PubMed ID: 29413822 [TBL] [Abstract][Full Text] [Related]
46. Reference dosimetry in magnetic fields: formalism and ionization chamber correction factors. O'Brien DJ; Roberts DA; Ibbott GS; Sawakuchi GO Med Phys; 2016 Aug; 43(8):4915. PubMed ID: 27487908 [TBL] [Abstract][Full Text] [Related]
47. Performance parameters of a liquid filled ionization chamber array. Poppe B; Stelljes TS; Looe HK; Chofor N; Harder D; Willborn K Med Phys; 2013 Aug; 40(8):082106. PubMed ID: 23927343 [TBL] [Abstract][Full Text] [Related]
48. The polarity effect of compact ionization chambers used for small field dosimetry. Looe HK; Büsing I; Tekin T; Brant A; Delfs B; Poppinga D; Poppe B Med Phys; 2018 Dec; 45(12):5608-5621. PubMed ID: 30294821 [TBL] [Abstract][Full Text] [Related]
49. Small field dosimetry correction factors for circular and MLC shaped fields with the CyberKnife M6 System: evaluation of the PTW 60023 microSilicon detector. Francescon P; Kilby W; Noll JM; Satariano N; Orlandi C Phys Med Biol; 2020 Jan; 65(1):01NT01. PubMed ID: 31829983 [TBL] [Abstract][Full Text] [Related]
50. Experimental determination of the lateral dose response functions of detectors to be applied in the measurement of narrow photon-beam dose profiles. Poppinga D; Meyners J; Delfs B; Muru A; Harder D; Poppe B; Looe HK Phys Med Biol; 2015 Dec; 60(24):9421-36. PubMed ID: 26583596 [TBL] [Abstract][Full Text] [Related]
51. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry measurements on a CyberKnife. Chalkley A; Heyes G Br J Radiol; 2014 Mar; 87(1035):20130768. PubMed ID: 24588671 [TBL] [Abstract][Full Text] [Related]
52. Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations. Francescon P; Cora S; Satariano N Med Phys; 2011 Dec; 38(12):6513-27. PubMed ID: 22149834 [TBL] [Abstract][Full Text] [Related]
53. The role of the construction and sensitive volume of compact ionization chambers on the magnetic field-dependent dose response. Delfs B; Blum I; Tekin T; Schönfeld AB; Kranzer R; Poppinga D; Giesen U; Langner F; Kapsch RP; Poppe B; Looe HK Med Phys; 2021 Aug; 48(8):4572-4585. PubMed ID: 34032298 [TBL] [Abstract][Full Text] [Related]
54. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams. Azangwe G; Grochowska P; Georg D; Izewska J; Hopfgartner J; Lechner W; Andersen CE; Beierholm AR; Helt-Hansen J; Mizuno H; Fukumura A; Yajima K; Gouldstone C; Sharpe P; Meghzifene A; Palmans H Med Phys; 2014 Jul; 41(7):072103. PubMed ID: 24989398 [TBL] [Abstract][Full Text] [Related]
55. A new single crystal diamond dosimeter for small beam: comparison with different commercial active detectors. Marsolat F; Tromson D; Tranchant N; Pomorski M; Le Roy M; Donois M; Moignau F; Ostrowsky A; De Carlan L; Bassinet C; Huet C; Derreumaux S; Chea M; Cristina K; Boisserie G; Bergonzo P Phys Med Biol; 2013 Nov; 58(21):7647-60. PubMed ID: 24113353 [TBL] [Abstract][Full Text] [Related]
56. Ionization chamber gradient effects in nonstandard beam configurations. Bouchard H; Seuntjens J; Carrier JF; Kawrakow I Med Phys; 2009 Oct; 36(10):4654-63. PubMed ID: 19928097 [TBL] [Abstract][Full Text] [Related]
57. 6-MV small field output factors: intra-/intermachine comparison and implementation of TRS-483 using various detectors and several linear accelerators. Ghazal M; Westermark M; Kaveckyte V; Carlsson-Tedgren Å; Benmakhlouf H Med Phys; 2019 Nov; 46(11):5350-5359. PubMed ID: 31532831 [TBL] [Abstract][Full Text] [Related]
58. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife. Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089 [TBL] [Abstract][Full Text] [Related]
59. On the implementation of the plan-class specific reference field using multidimensional clustering of plan features and alternative strategies for improved dosimetry in modulated clinical linear accelerator treatments. Desai VK; Labby ZE; DeWerd LA; Culberson WS Med Phys; 2020 Aug; 47(8):3621-3635. PubMed ID: 32337734 [TBL] [Abstract][Full Text] [Related]
60. On the implementation of a recently proposed dosimetric formalism to a robotic radiosurgery system. Pantelis E; Moutsatsos A; Zourari K; Kilby W; Antypas C; Papagiannis P; Karaiskos P; Georgiou E; Sakelliou L Med Phys; 2010 May; 37(5):2369-79. PubMed ID: 20527571 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]