166 related articles for article (PubMed ID: 23927349)
1. A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.
Rong X; Frey EC
Med Phys; 2013 Aug; 40(8):082504. PubMed ID: 23927349
[TBL] [Abstract][Full Text] [Related]
2. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.
Rong X; Du Y; Frey EC
Phys Med Biol; 2012 Jun; 57(12):3711-25. PubMed ID: 22617760
[TBL] [Abstract][Full Text] [Related]
3. Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch.
Rong X; Ghaly M; Frey EC
Med Phys; 2013 Jun; 40(6):062502. PubMed ID: 23718607
[TBL] [Abstract][Full Text] [Related]
4. Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.
Rong X; Du Y; Ljungberg M; Rault E; Vandenberghe S; Frey EC
Med Phys; 2012 May; 39(5):2346-58. PubMed ID: 22559605
[TBL] [Abstract][Full Text] [Related]
5. Evaluation the effect of different collimators and energy window on Y-90 bremsstrahlung SPECT imaging by SIMIND Monte Carlo program.
Taherparvar P; Shahmari N
Nucl Med Rev Cent East Eur; 2019; 22(2):45-55. PubMed ID: 31482556
[TBL] [Abstract][Full Text] [Related]
6. Collimator and energy window optimization for ⁹⁰Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study.
Roshan HR; Mahmoudian B; Gharepapagh E; Azarm A; Pirayesh Islamian J
Appl Radiat Isot; 2016 Feb; 108():124-128. PubMed ID: 26720261
[TBL] [Abstract][Full Text] [Related]
7. Quantitative Monte Carlo-based 90Y SPECT reconstruction.
Elschot M; Lam MG; van den Bosch MA; Viergever MA; de Jong HW
J Nucl Med; 2013 Sep; 54(9):1557-63. PubMed ID: 23907758
[TBL] [Abstract][Full Text] [Related]
8. SPECT performance evaluation on image of Yttrium 90 - Bremsstrahlung using Monte Carlo simulation.
Pastrana Orejuela CO; de Assis Coelho F; Oliveira SM; Souza SAL; Vasconcellos de Sá L; Xavier da Silva A; Torres Berdeguez MB
Appl Radiat Isot; 2021 Feb; 168():109456. PubMed ID: 33321371
[TBL] [Abstract][Full Text] [Related]
9. Improved quantitative
Dewaraja YK; Chun SY; Srinivasa RN; Kaza RK; Cuneo KC; Majdalany BS; Novelli PM; Ljungberg M; Fessler JA
Med Phys; 2017 Dec; 44(12):6364-6376. PubMed ID: 28940483
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo simulation of PET and SPECT imaging of 90Y.
Takahashi A; Himuro K; Yamashita Y; Komiya I; Baba S; Sasaki M
Med Phys; 2015 Apr; 42(4):1926-35. PubMed ID: 25832083
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of quantitative (90)Y SPECT based on experimental phantom studies.
Minarik D; Sjögreen Gleisner K; Ljungberg M
Phys Med Biol; 2008 Oct; 53(20):5689-703. PubMed ID: 18812648
[TBL] [Abstract][Full Text] [Related]
12. Fast simulation of yttrium-90 bremsstrahlung photons with GATE.
Rault E; Staelens S; Van Holen R; De Beenhouwer J; Vandenberghe S
Med Phys; 2010 Jun; 37(6):2943-50. PubMed ID: 20632606
[TBL] [Abstract][Full Text] [Related]
13. Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.
Ghaly M; Links JM; Frey EC
Phys Med Biol; 2016 Mar; 61(5):2109-23. PubMed ID: 26894376
[TBL] [Abstract][Full Text] [Related]
14. Quantitative Monte Carlo-based holmium-166 SPECT reconstruction.
Elschot M; Smits ML; Nijsen JF; Lam MG; Zonnenberg BA; van den Bosch MA; Viergever MA; de Jong HW
Med Phys; 2013 Nov; 40(11):112502. PubMed ID: 24320461
[TBL] [Abstract][Full Text] [Related]
15. A parallel-cone collimator for high-energy SPECT.
Beijst C; Elschot M; Viergever MA; de Jong HW
J Nucl Med; 2015 Mar; 56(3):476-82. PubMed ID: 25655627
[TBL] [Abstract][Full Text] [Related]
16. Primary, scatter, and penetration characterizations of parallel-hole and pinhole collimators for I-123 SPECT.
Könik A; Auer B; De Beenhouwer J; Kalluri K; Zeraatkar N; Furenlid LR; King MA
Phys Med Biol; 2019 Dec; 64(24):245001. PubMed ID: 31746783
[TBL] [Abstract][Full Text] [Related]
17. Planar gamma camera imaging and quantitation of yttrium-90 bremsstrahlung.
Shen S; DeNardo GL; Yuan A; DeNardo DA; DeNardo SJ
J Nucl Med; 1994 Aug; 35(8):1381-9. PubMed ID: 8046498
[TBL] [Abstract][Full Text] [Related]
18. Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera.
Pourmoghaddas A; Wells RG
Med Phys; 2016 Nov; 43(11):6098. PubMed ID: 27806581
[TBL] [Abstract][Full Text] [Related]
19.
Debebe SA; Adjouadi M; Gulec SA; Franquiz J; McGoron AJ
J Appl Clin Med Phys; 2019 Feb; 20(2):30-42. PubMed ID: 30628156
[TBL] [Abstract][Full Text] [Related]
20. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.
Ghaly M; Du Y; Links JM; Frey EC
Phys Med Biol; 2016 Mar; 61(5):2048-66. PubMed ID: 26895287
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]