  • 1. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia: case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 23931255
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia. Case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 24565248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Intraoperative acute airway obstruction due to the damage of a reinforced endotracheal tube in thyroidectomy].
    Ida M; Kuzumoto N; Nakayama K; Krimoto K; Kamiya T; Iwata M; Shimomura T
    Masui; 2014 Oct; 63(10):1128-30. PubMed ID: 25693343
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient.
    Rajkumar A; Bajekal R
    J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451
    [No Abstract]   [Full Text] [Related]  

  • 6. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 7. Impending Complete Airway Obstruction from a Reinforced Orotracheal Tube: a Case Report.
    Hosseinzadeh N; Samadi S; Jafari Javid M; Takzare A
    Acta Med Iran; 2015; 53(9):590-2. PubMed ID: 26553090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Airway obstruction by an unexpected equipment damage.
    Schober P; Loer SA; Schwarte LA
    J Clin Anesth; 2016 Aug; 32():59-61. PubMed ID: 27290946
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Rare Airway Obstruction Caused by Dissection of a Reinforced Endotracheal Tube.
    Choi YH; Lee DH
    J Emerg Med; 2018 Apr; 54(4):e73-e75. PubMed ID: 29395694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Obstruction of endotracheal tube; a manufacturing error.
    Hajimohammadi F; Taheri A; Eghtesadi-Araghi P
    Middle East J Anaesthesiol; 2009 Jun; 20(2):303-5. PubMed ID: 19583085
    [No Abstract]   [Full Text] [Related]  

  • 11. Impacted gum-elastic bougie in an endotracheal tube after successful intubation of a difficult airway.
    Arya VK; Makker S; Bedi SP
    J Clin Anesth; 2007 Nov; 19(7):566. PubMed ID: 18063220
    [No Abstract]   [Full Text] [Related]  

  • 12. A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
    Sharma A; Jain V; Mitra JK; Prabhakar H
    Middle East J Anaesthesiol; 2008 Feb; 19(4):909-11. PubMed ID: 18630777
    [No Abstract]   [Full Text] [Related]  

  • 13. [Case report: lumen obstruction with a Magill tube].
    Deller A; Weichel T
    Anasth Intensivther Notfallmed; 1990 Aug; 25(4):293-4. PubMed ID: 2221303
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Silicone-based endotracheal tube causing airway obstruction and pneumothorax.
    Capra GG; Shah AN; Moore JD; Halsey WS; Lujan E
    Arch Otolaryngol Head Neck Surg; 2012 Jun; 138(6):588-91. PubMed ID: 22710512
    [No Abstract]   [Full Text] [Related]  

  • 15. [Internal blistering of armored latex endotracheal tubes].
    Rouco Martínez I; Catalá Puigbó E; Baxarias Gascón P
    Rev Esp Anestesiol Reanim; 1984; 31(5):208-10. PubMed ID: 6505343
    [No Abstract]   [Full Text] [Related]  

  • 16. Laser endotracheal tube failure: kinking of the Rüsch Lasertubus resulting in near-total airway occlusion.
    Weingarten TN; Hein B; Long TR; Wass CT
    J Clin Anesth; 2004 Sep; 16(6):452-4. PubMed ID: 15567651
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Partial airway obstruction caused by dissection of a reinforced endotracheal tube.
    Jeon YS; Kim YS; Joo JD; Kang EG; In JH; Choi JW; Cho SM
    Eur J Anaesthesiol; 2007 Nov; 24(11):983-4. PubMed ID: 18035602
    [No Abstract]   [Full Text] [Related]  

  • 18. Aspiration of a dislodged endotracheal tube: a rare cause of acute total airway obstruction.
    Wong SY; Tseng CH; Wong KM; Chen KT; Chen C
    Chang Gung Med J; 2003 Jul; 26(7):515-9. PubMed ID: 14515975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Obstruction of the left upper lobar bronchus by a double-lumen endotracheal tube. Apropos of a case].
    Pueyo JA; Fuentes R; Bustos A; Guerrero MI; Torres LM
    Rev Esp Anestesiol Reanim; 1992; 39(2):134. PubMed ID: 1594783
    [No Abstract]   [Full Text] [Related]  

  • 20. An unusual foreign body obstructing endotracheal tube connector.
    Roy B; Barman B; Dutta C; Basu SM
    J Indian Med Assoc; 1995 Sep; 93(9):358. PubMed ID: 8648160
    [No Abstract]   [Full Text] [Related]  