These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 23932026)

  • 1. A dual-channel gas chromatography method for the quantitation of low and high concentrations of NF3 and CF4 to study membrane separation of the two compounds.
    Branken DJ; le Roux JP; Krieg HM; Lachmann G
    J Chromatogr A; 2013 Sep; 1307():180-90. PubMed ID: 23932026
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimisation of a gas chromatographic method for trace gaseous impurities in nitrogen trifluoride by column sequence reversal.
    de Coning JP; Swinley JM
    J Chromatogr A; 2008 Feb; 1180(1-2):151-8. PubMed ID: 18155712
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Trace analysis of impurities in bulk gases by gas chromatography-pulsed discharge helium ionization detection with "heart-cutting" technique.
    Weijun Y
    J Chromatogr A; 2007 Oct; 1167(2):225-30. PubMed ID: 17850804
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulsed discharge helium ionization detector with multiple combined bias/collecting electrodes for gas chromatography.
    Cai H; Stearns SD
    J Chromatogr A; 2013 Apr; 1284():163-73. PubMed ID: 23484651
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of trace amounts of carbon dioxide, oxygen and carbon monoxide in nitrogen using dual capillary columns and a pulsed discharge helium ionisation detector.
    Janse van Rensburg M; Botha A; Rohwer E
    J Chromatogr A; 2007 Oct; 1167(1):102-8. PubMed ID: 17765907
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of removal efficiency of perfluorocompounds (PFCs) in a semiconductor fabrication plant by gas chromatography.
    Ou Yang CF; Kam SH; Liu CH; Tzou J; Wang JL
    Chemosphere; 2009 Aug; 76(9):1273-7. PubMed ID: 19604537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.
    Roberge MT; Finley JW; Lukaski HC; Borgerding AJ
    J Chromatogr A; 2004 Feb; 1027(1-2):19-23. PubMed ID: 14971479
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of target-gas purity on the chemical form of F-18 during 18F-F2 production using the neon/fluorine target.
    Bida GT; Ehrenkaufer RL; Wolf AP; Fowler JS; MacGregor RR; Ruth TJ
    J Nucl Med; 1980 Aug; 21(8):758-62. PubMed ID: 6772745
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amino-Functionalized Microporous MOFs for Capturing Greenhouse Gases CF
    Wang SM; Lan HL; Guan GW; Yang QY
    ACS Appl Mater Interfaces; 2022 Sep; 14(35):40072-40081. PubMed ID: 36001809
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of experimental parameters on NF(3) decomposition fraction in an oxygen-based RF plasma environment.
    Wang YF; Wang LC; Shih M; Tsai CH
    Chemosphere; 2004 Dec; 57(9):1157-63. PubMed ID: 15504475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New benchmark for basic and neutral nitrogen compounds speciation in middle distillates using comprehensive two-dimensional gas chromatography.
    Adam F; Bertoncini F; Brodusch N; Durand E; Thiébaut D; Espinat D; Hennion MC
    J Chromatogr A; 2007 Apr; 1148(1):55-64. PubMed ID: 17379235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic potential of the pulsed discharged helium ionization detector (PDHID) for pathogenic Mycobacterial volatile biomarkers.
    Manginell RP; Pimentel AS; Mowry CD; Mangan MA; Moorman MW; Allen A; Schares ES; Achyuthan KE
    J Breath Res; 2013 Sep; 7(3):037107. PubMed ID: 23867723
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a Mesoscale Pulsed Discharge Helium Ionization Detector for Portable Gas Chromatography.
    Manginell RP; Mowry CD; Pimentel AS; Mangan MA; Moorman MW; Sparks ES; Allen A; Achyuthan KE
    Anal Sci; 2015; 31(11):1183-8. PubMed ID: 26561264
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a pulse-discharge helium ionisation detector for the determination of neon concentrations by gas chromatography.
    Lasa J; Mochalski P; Pusz J
    J Chromatogr A; 2004 May; 1035(2):261-4. PubMed ID: 15124819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multidimensional gas chromatography for the characterization of permanent gases and light hydrocarbons in catalytic cracking process.
    Luong J; Gras R; Cortes HJ; Shellie RA
    J Chromatogr A; 2013 Jan; 1271(1):185-91. PubMed ID: 23218191
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prediction of theoretical plate number in isothermal gas chromatographic analysis on capillary columns.
    Moretti P; Vezzani S; Castello G
    J Chromatogr A; 2006 Nov; 1133(1-2):305-14. PubMed ID: 16959257
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On retentivity tuning by flow in the second column of different comprehensive two dimensional gas chromatographic configurations.
    Krupčík J; Májek P; Gorovenko R; Sandra P; Armstrong DW
    J Chromatogr A; 2011 May; 1218(21):3186-9. PubMed ID: 21489538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.
    Liu J; Seo JH; Li Y; Chen D; Kurabayashi K; Fan X
    Lab Chip; 2013 Mar; 13(5):818-25. PubMed ID: 23303462
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multidimensional gas chromatography using microfluidic switching and low thermal mass gas chromatography for the characterization of targeted volatile organic compounds.
    Luong J; Gras R; Hawryluk M; Shellie RA; Cortes HJ
    J Chromatogr A; 2013 May; 1288():105-10. PubMed ID: 23523064
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On-line gas chromatographic analysis of higher alcohol synthesis products from syngas.
    Andersson R; Boutonnet M; Järås S
    J Chromatogr A; 2012 Jul; 1247():134-45. PubMed ID: 22687712
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.