190 related articles for article (PubMed ID: 23932493)
1. Realization of radioactive equilibrium in the KRISS radon chamber.
Lee MS; Park TS; Lee JM
Appl Radiat Isot; 2013 Nov; 81():226-9. PubMed ID: 23932493
[TBL] [Abstract][Full Text] [Related]
2. Calibration of the KRISS reference ionization chamber for certification of ²²²Rn gaseous sources.
Lee JM; Lee KB; Lee SH; Oh PJ; Park TS; Kim BC; Lee MS
Appl Radiat Isot; 2013 Nov; 81():230-2. PubMed ID: 23611814
[TBL] [Abstract][Full Text] [Related]
3. Development of the primary measurement standard for gaseous radon-222 activity.
Kim BC; Lee KB; Park TS; Lee JM; Lee SH; Oh PJ; Lee MK; Ahn JK
Appl Radiat Isot; 2012 Sep; 70(9):1934-9. PubMed ID: 22607994
[TBL] [Abstract][Full Text] [Related]
4. Calibration of diffusion barrier charcoal detectors using a semi-empirical expression.
Montero Cabrera ME; Sujo LC; Villalba L; Peinado JS; Jiménez AC; Miranda AL; Peraza EF
Appl Radiat Isot; 2003 Oct; 59(4):281-7. PubMed ID: 14522237
[TBL] [Abstract][Full Text] [Related]
5. Dependence of the LR-115 radon detector calibration factor on track density.
De Cicco F; Pugliese M; Roca V; Sabbarese C
Appl Radiat Isot; 2013 Aug; 78():108-12. PubMed ID: 23694685
[TBL] [Abstract][Full Text] [Related]
6. Radon activity concentration--a Euromet and BIPM supplementary comparison.
Röttger A; Honig A; Schmidt V; Buchröder H; Rox A; Butterweck G; Schuler Ch; Maringer FJ; Jachs P; Edelmaier R; Michielsen N; Howarth CB; Miles JC; Vargas A; Ortega X; Burian I; Turtiainen T; Hagberg N
Appl Radiat Isot; 2006; 64(10-11):1102-7. PubMed ID: 16580217
[TBL] [Abstract][Full Text] [Related]
7. Calibration of the Politrack® system based on CR39 solid-state nuclear track detectors for passive indoor radon concentration measurements.
Kropat G; Baechler S; Bailat C; Barazza F; Bochud F; Damet J; Meyer N; Palacios Gruson M; Butterweck G
Radiat Prot Dosimetry; 2015 Nov; 167(1-3):302-5. PubMed ID: 25948829
[TBL] [Abstract][Full Text] [Related]
8. Fraction of the positive 218Po and 214Pb clusters in indoor air.
Porstendörfer J; Pagelkopf P; Gründel M
Radiat Prot Dosimetry; 2005; 113(3):342-51. PubMed ID: 15829554
[TBL] [Abstract][Full Text] [Related]
9. Development of calibration facility for radon and its progenies at NIM (China).
Liang JC; Zheng PH; Yang ZJ; Liu HR; Zhang M; Li ZS; Zhang L; Guo QJ
Radiat Prot Dosimetry; 2015 Nov; 167(1-3):82-6. PubMed ID: 25948838
[TBL] [Abstract][Full Text] [Related]
10. Determining radioactive aerosol concentrations using a surface radioactive contamination measurement device.
Cerny R; Johnova K; Kozlovska M; Otahal P; Vosahlikova I
Radiat Prot Dosimetry; 2015 Jun; 164(4):533-6. PubMed ID: 25979746
[TBL] [Abstract][Full Text] [Related]
11. A comparative study of the radon-induced background in low-level gamma-ray spectrometers.
Maver Modec P; Korun M; Martelanc M; Vodenik B
Appl Radiat Isot; 2012 Jan; 70(1):324-31. PubMed ID: 22014892
[TBL] [Abstract][Full Text] [Related]
12. Determination of blank indication of active radon monitors.
Cardellini F; De Felice P; Pagliari M
Appl Radiat Isot; 2013 Nov; 81():242-7. PubMed ID: 23651549
[TBL] [Abstract][Full Text] [Related]
13. Development of a low-level radon reference atmosphere.
Linzmaier D; Röttger A
Appl Radiat Isot; 2013 Nov; 81():208-11. PubMed ID: 23562434
[TBL] [Abstract][Full Text] [Related]
14. Czech primary radon measurement equipment.
Burian I; Otahal P; Vosahlik J; Pilecka E
Radiat Prot Dosimetry; 2011 May; 145(2-3):333-6. PubMed ID: 21482617
[TBL] [Abstract][Full Text] [Related]
15. Simultaneous Measurements of Nanoaerosols and Radioactive Aerosols Containing the Short-lived Radon Isotopes.
Otahal PPS; Burian I; Ondracek J; Zdimal V; Holub RF
Radiat Prot Dosimetry; 2017 Nov; 177(1-2):53-56. PubMed ID: 29036690
[TBL] [Abstract][Full Text] [Related]
16. Influence of natural radioactive aerosols on artificial radioactivity detection in the Spanish surveillance networks.
Vargas A; Arnold D; Ortega X; Parages C
Appl Radiat Isot; 2008 Nov; 66(11):1627-31. PubMed ID: 18511289
[TBL] [Abstract][Full Text] [Related]
17. Detection properties of a measuring system for a continuous soil radon concentrations monitoring.
Fronka A; Moucka L; Jerábek M
Radiat Prot Dosimetry; 2008; 130(1):56-9. PubMed ID: 18407971
[TBL] [Abstract][Full Text] [Related]
18. Critical level setting of continuous air monitor.
Li H; Jia M; Wang K
Radiat Prot Dosimetry; 2013; 154(3):391-5. PubMed ID: 23051585
[TBL] [Abstract][Full Text] [Related]
19. Development of a primary thoron activity standard for the calibration of thoron measurement instruments.
Sabot B; Pierre S; Cassette P; Michielsen N; Bondiguel S
Radiat Prot Dosimetry; 2015 Nov; 167(1-3):70-4. PubMed ID: 25911408
[TBL] [Abstract][Full Text] [Related]
20. Performance comparison of electronic radon monitors.
Lin CF; Wang JJ; Lin SJ; Lin CK
Appl Radiat Isot; 2013 Nov; 81():238-41. PubMed ID: 23566805
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]