  • 21. Conductor externalization in a Riata ST Optim™ lead.
    Deeprasertkul P; Yunus A; Thakur R
    Europace; 2013 Jul; 15(7):1012. PubMed ID: 23419661
    [No Abstract]   [Full Text] [Related]  

  • 22. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads.
    Kubala M; Traullé S; Leborgne L; Hermida JS
    Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simultaneous treatment of patent foramen ovale and pulmonary arteriovenous fistula in a patient with paradoxical embolism.
    Gaspardone A; Citone C; Gioffrè G; Iamele M; Befani L; Papa M
    J Cardiovasc Med (Hagerstown); 2008 Mar; 9(3):325-6. PubMed ID: 18301162
    [No Abstract]   [Full Text] [Related]  

  • 24. Detection of high incidence of Riata lead breaches by systematic postero-anterior and lateral chest X-ray in a large cohort.
    Steinberg C; Sarrazin JF; Philippon F; Bouchard MA; O'Hara G; Molin F; Nault I; Blier L; Champagne J
    Europace; 2013 Mar; 15(3):402-8. PubMed ID: 23118004
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Long-term performance and lead failure analysis of the Durata defibrillation lead compared to its previous model, the recalled Riata defibrillation lead.
    Kleemann T; Nonnenmacher F; Strauss M; Kouraki K; Werner N; Fendt A; Zahn R
    J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2012-2019. PubMed ID: 31332876
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cryptogenic stroke and patent foramen ovale.
    Thaler DE; Saver JL
    Curr Opin Cardiol; 2008 Nov; 23(6):537-44. PubMed ID: 18830067
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prevalence and predictors of cable extrusion and loss of electrical integrity with the Riata defibrillator lead.
    Shen S; Bhave P; Giedrimas E; Patel T; Arora R; Chicos AB; Goldberger JJ; Ilkhanoff L; Kim MH; Lin AC; Passman R; Lee R; Knight BP; Kim SS
    J Cardiovasc Electrophysiol; 2012 Nov; 23(11):1207-12. PubMed ID: 22697600
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pulmonary thromboembolism along with an impending paradoxical embolism across patent foramen ovale.
    Vijayvergiya R; Kanabar K; Budakoty S; Guleria V; Kaur N; Lal A
    J Echocardiogr; 2020 Dec; 18(4):258-259. PubMed ID: 31230223
    [No Abstract]   [Full Text] [Related]  

  • 29. Recurrent events following patent foramen ovale closure in patients above 55 years of age with presumed paradoxical embolism.
    Spies C; Khandelwal A; Timmemanns I; Kavinsky CJ; Schräder R; Hijazi ZM
    Catheter Cardiovasc Interv; 2008 Dec; 72(7):966-70. PubMed ID: 18942060
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Closure of patent foramen ovale: The abolition of stroke and asymptotic realities.
    Tan WA
    Catheter Cardiovasc Interv; 2004 Aug; 62(4):517-8. PubMed ID: 15274164
    [No Abstract]   [Full Text] [Related]  

  • 31. Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey.
    Grazia Bongiorni M; Dagres N; Estner H; Pison L; Todd D; Blomstrom-Lundqvist C;
    Europace; 2014 Nov; 16(11):1674-8. PubMed ID: 25344962
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Management of recalled implantable cardioverter-defibrillator leads at generator replacement: a decision analysis model for Fidelis leads.
    Burri H; Combescure C
    Europace; 2014 Aug; 16(8):1210-7. PubMed ID: 24469434
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Percutaneous closure of patent foramen ovale in patients with presumed paradoxical embolism: periprocedural results and midterm risk of recurrent neurologic events.
    Balbi M; Casalino L; Gnecco G; Bezante GP; Pongiglione G; Marasini M; Del Sette M; Barsotti A
    Am Heart J; 2008 Aug; 156(2):356-60. PubMed ID: 18657668
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lead thrombi associated with externalized cables on Riata ICD leads: a case series.
    Goyal SK; Ellis CR; Rottman JN; Whalen SP
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1047-50. PubMed ID: 23577693
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Massive pulmonary embolism and acute limb ischaemia in a patient of hereditary spherocytosis and patent foramen ovale.
    Agarwal SK; Binbrek AS; Thompson JA; Siddiqui SA
    Heart Lung Circ; 2010 Dec; 19(12):742-4. PubMed ID: 20619736
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Economy class syndrome complicated by stroke: a rare condition due to paradoxical embolism--a case report and review of the literature.
    Scacciatella P; Butera G; Amato G; Tomassini F; Giorgi M; Marra S
    J Cardiovasc Med (Hagerstown); 2011 Aug; 12(8):595-7. PubMed ID: 20407383
    [No Abstract]   [Full Text] [Related]  

  • 37. Patent foramen ovale closure with the Intrasept occluder: Complete 6-56 months follow-up of 247 patients after presumed paradoxical embolism.
    Spies C; Timmermanns I; Reissmann U; van Essen J; Schräder R
    Catheter Cardiovasc Interv; 2008 Feb; 71(3):390-5. PubMed ID: 18288745
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Relationship between patent foramen ovale and ischemic cerebrovascular events in children.
    Sharma VK; Teoh HL; Chan BP
    Catheter Cardiovasc Interv; 2008 Apr; 71(5):716-7; author reply 718. PubMed ID: 18360872
    [No Abstract]   [Full Text] [Related]  

  • 39. Patent foramen ovale, systemic embolization, and closure.
    Holmes DR; Cohen HA; Ruiz C
    Curr Probl Cardiol; 2009 Oct; 34(10):483-530. PubMed ID: 19733784
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The Canadian experience with Durata and Riata ST Optim defibrillator leads: a report from the Canadian Heart Rhythm Society Device Committee.
    Bennett MT; Ha AC; Exner DV; Tung SK; Parkash R; Connors S; Coutu B; Crystal E; Champagne J; Philippon F; Yee R; Stephenson EA; Nery PB; Essebag V; Sanatani S; Redfearn D; Krahn AD; Healey JS
    Heart Rhythm; 2013 Oct; 10(10):1478-81. PubMed ID: 23973950
    [TBL] [Abstract][Full Text] [Related]  