These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

472 related articles for article (PubMed ID: 23944875)

  • 1. Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis.
    Nimri R; Muller I; Atlas E; Miller S; Kordonouri O; Bratina N; Tsioli C; Stefanija MA; Danne T; Battelino T; Phillip M
    Pediatr Diabetes; 2014 Mar; 15(2):91-9. PubMed ID: 23944875
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The "Glucositter" overnight automated closed loop system for type 1 diabetes: a randomized crossover trial.
    Nimri R; Danne T; Kordonouri O; Atlas E; Bratina N; Biester T; Avbelj M; Miller S; Muller I; Phillip M; Battelino T
    Pediatr Diabetes; 2013 May; 14(3):159-67. PubMed ID: 23448393
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MD-Logic overnight type 1 diabetes control in home settings: A multicentre, multinational, single blind randomized trial.
    Nimri R; Bratina N; Kordonouri O; Avbelj Stefanija M; Fath M; Biester T; Muller I; Atlas E; Miller S; Fogel A; Phillip M; Danne T; Battelino T
    Diabetes Obes Metab; 2017 Apr; 19(4):553-561. PubMed ID: 27981804
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial.
    Nimri R; Muller I; Atlas E; Miller S; Fogel A; Bratina N; Kordonouri O; Battelino T; Danne T; Phillip M
    Diabetes Care; 2014 Nov; 37(11):3025-32. PubMed ID: 25078901
    [TBL] [Abstract][Full Text] [Related]  

  • 5. DREAM5: An open-label, randomized, cross-over study to evaluate the safety and efficacy of day and night closed-loop control by comparing the MD-Logic automated insulin delivery system to sensor augmented pump therapy in patients with type 1 diabetes at home.
    Biester T; Nir J; Remus K; Farfel A; Muller I; Biester S; Atlas E; Dovc K; Bratina N; Kordonouri O; Battelino T; Philip M; Danne T; Nimri R
    Diabetes Obes Metab; 2019 Apr; 21(4):822-828. PubMed ID: 30478937
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial.
    Kropff J; Del Favero S; Place J; Toffanin C; Visentin R; Monaro M; Messori M; Di Palma F; Lanzola G; Farret A; Boscari F; Galasso S; Magni P; Avogaro A; Keith-Hynes P; Kovatchev BP; Bruttomesso D; Cobelli C; DeVries JH; Renard E; Magni L;
    Lancet Diabetes Endocrinol; 2015 Dec; 3(12):939-47. PubMed ID: 26432775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial.
    Haidar A; Legault L; Matteau-Pelletier L; Messier V; Dallaire M; Ladouceur M; Rabasa-Lhoret R
    Lancet Diabetes Endocrinol; 2015 Aug; 3(8):595-604. PubMed ID: 26066705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility study of automated overnight closed-loop glucose control under MD-logic artificial pancreas in patients with type 1 diabetes: the DREAM Project.
    Nimri R; Atlas E; Ajzensztejn M; Miller S; Oron T; Phillip M
    Diabetes Technol Ther; 2012 Aug; 14(8):728-35. PubMed ID: 22853723
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Overnight closed-loop insulin delivery in young people with type 1 diabetes: a free-living, randomized clinical trial.
    Hovorka R; Elleri D; Thabit H; Allen JM; Leelarathna L; El-Khairi R; Kumareswaran K; Caldwell K; Calhoun P; Kollman C; Murphy HR; Acerini CL; Wilinska ME; Nodale M; Dunger DB
    Diabetes Care; 2014; 37(5):1204-11. PubMed ID: 24757227
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multinight "bedside" closed-loop control for patients with type 1 diabetes.
    Brown SA; Kovatchev BP; Breton MD; Anderson SM; Keith-Hynes P; Patek SD; Jiang B; Ben Brahim N; Vereshchetin P; Bruttomesso D; Avogaro A; Del Favero S; Boscari F; Galasso S; Visentin R; Monaro M; Cobelli C
    Diabetes Technol Ther; 2015 Mar; 17(3):203-9. PubMed ID: 25594434
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nocturnal glucose control with an artificial pancreas at a diabetes camp.
    Phillip M; Battelino T; Atlas E; Kordonouri O; Bratina N; Miller S; Biester T; Stefanija MA; Muller I; Nimri R; Danne T
    N Engl J Med; 2013 Feb; 368(9):824-33. PubMed ID: 23445093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Day-and-Night Closed-Loop Glucose Control in Patients With Type 1 Diabetes Under Free-Living Conditions: Results of a Single-Arm 1-Month Experience Compared With a Previously Reported Feasibility Study of Evening and Night at Home.
    Renard E; Farret A; Kropff J; Bruttomesso D; Messori M; Place J; Visentin R; Calore R; Toffanin C; Di Palma F; Lanzola G; Magni P; Boscari F; Galasso S; Avogaro A; Keith-Hynes P; Kovatchev B; Del Favero S; Cobelli C; Magni L; DeVries JH;
    Diabetes Care; 2016 Jul; 39(7):1151-60. PubMed ID: 27208331
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial.
    Abitbol A; Rabasa-Lhoret R; Messier V; Legault L; Smaoui M; Cohen N; Haidar A
    Diabetes Technol Ther; 2018 Mar; 20(3):189-196. PubMed ID: 29393675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes camp.
    Ly TT; Breton MD; Keith-Hynes P; De Salvo D; Clinton P; Benassi K; Mize B; Chernavvsky D; Place J; Wilson DM; Kovatchev BP; Buckingham BA
    Diabetes Care; 2014 Aug; 37(8):2310-6. PubMed ID: 24879841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.
    Haidar A; Legault L; Messier V; Mitre TM; Leroux C; Rabasa-Lhoret R
    Lancet Diabetes Endocrinol; 2015 Jan; 3(1):17-26. PubMed ID: 25434967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes.
    Haidar A; Rabasa-Lhoret R; Legault L; Lovblom LE; Rakheja R; Messier V; D'Aoust É; Falappa CM; Justice T; Orszag A; Tschirhart H; Dallaire M; Ladouceur M; Perkins BA
    J Clin Endocrinol Metab; 2016 Jan; 101(1):214-23. PubMed ID: 26523526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies.
    Wilinska ME; Budiman ES; Taub MB; Elleri D; Allen JM; Acerini CL; Dunger DB; Hovorka R
    J Diabetes Sci Technol; 2009 Sep; 3(5):1109-20. PubMed ID: 20144424
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study.
    Thabit H; Lubina-Solomon A; Stadler M; Leelarathna L; Walkinshaw E; Pernet A; Allen JM; Iqbal A; Choudhary P; Kumareswaran K; Nodale M; Nisbet C; Wilinska ME; Barnard KD; Dunger DB; Heller SR; Amiel SA; Evans ML; Hovorka R
    Lancet Diabetes Endocrinol; 2014 Sep; 2(9):701-9. PubMed ID: 24943065
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multinational Home Use of Closed-Loop Control Is Safe and Effective.
    Anderson SM; Raghinaru D; Pinsker JE; Boscari F; Renard E; Buckingham BA; Nimri R; Doyle FJ; Brown SA; Keith-Hynes P; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Farret A; Place J; Ly TT; Shanmugham S; Phillip M; Dassau E; Dasanayake IS; Kollman C; Lum JW; Beck RW; Kovatchev B;
    Diabetes Care; 2016 Jul; 39(7):1143-50. PubMed ID: 27208316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Unsupervised home use of an overnight closed-loop system over 3-4 weeks: a pooled analysis of randomized controlled studies in adults and adolescents with type 1 diabetes.
    Thabit H; Elleri D; Leelarathna L; Allen JM; Lubina-Solomon A; Stadler M; Walkinshaw E; Iqbal A; Choudhary P; Wilinska ME; Barnard KD; Heller SR; Amiel SA; Evans ML; Dunger DB; Hovorka R
    Diabetes Obes Metab; 2015 May; 17(5):452-8. PubMed ID: 25492378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.